Mechanical Circulatory Support for AMI and Cardiogenic Shock

被引:11
作者
Abu-Omar, Yasir [1 ]
Tsui, Steven S. L. [1 ]
机构
[1] Papworth Hosp, Transplant Unit, Cambridge CB23 3RE, England
关键词
VENTRICULAR ASSIST DEVICE; ACUTE MYOCARDIAL-INFARCTION; INTRAAORTIC BALLOON SUPPORT; TOTAL ARTIFICIAL-HEART; CLINICAL-EXPERIENCE; CARDIAC TRANSPLANTATION; EARLY REVASCULARIZATION; BRIDGE; FAILURE; TANDEMHEART;
D O I
10.1111/j.1540-8191.2010.01018.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
P>Cardiogenic shock following acute myocardial infarction affects 5% to10% of patients and carries a grave prognosis. The dismal prognosis associated with post-MI cardiogenic shock, allied with surgical and technological advancements, has shifted the treatment paradigm toward wider use of mechanical circulatory support devices (MCSD). Current experience demonstrates that better outcomes may be achieved with early MCSD deployment (prior to the onset of end-organ dysfunction). However, perceived limitations with existing devices mean that they remain infrequently applied. There is an urgent need for increased awareness of MCSD options among clinicians treating post-MI shock patients. (J Card Surg 2010;25:434-441).
引用
收藏
页码:434 / 441
页数:8
相关论文
共 36 条
  • [1] Task force 1: The ACCF and AHA codes of conduct in human subjects research
    Adams, RJ
    Antman, EM
    Kavey, REW
    [J]. CIRCULATION, 2004, 110 (16) : 2512 - 2516
  • [2] PATHOPHYSIOLOGY OF CARDIOGENIC-SHOCK - QUANTIFICATION OF MYOCARDIAL NECROSIS, CLINICAL, PATHOLOGIC AND ELECTROCARDIOGRAPHIC CORRELATIONS
    ALONSO, DR
    SCHEIDT, S
    POST, M
    KILLIP, T
    [J]. CIRCULATION, 1973, 48 (03) : 588 - 596
  • [3] Bruckner BA, 2008, TEX HEART I J, V35, P447
  • [4] Feasibility study of the use of the TandemHeart® percutaneous ventricular assist device for treatment of cardiogenic shock
    Burkhoff, Daniel
    O'Neill, Williarn
    Brunckhorst, Corinna
    Letts, Dustin
    Lasorda, David
    Cohen, Howard A.
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2006, 68 (02) : 211 - 217
  • [5] Optimal timing of preoperative intraaortic balloon pump support in high-risk coronary patients
    Christenson, JT
    Simonet, F
    Badel, P
    Schmuziger, M
    [J]. ANNALS OF THORACIC SURGERY, 1999, 68 (03) : 934 - 939
  • [6] Cardiac replacement with a total artificial heart as a bridge to transplantation
    Copeland, JG
    Smith, RG
    Arabia, FA
    Nolan, PE
    Sethi, GK
    Tsau, PH
    McClellan, D
    Slepian, MJ
    Foy, B
    Long, J
    Doty, D
    Tector, A
    Kormos, R
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2004, 351 (09) : 859 - 867
  • [7] Dang NC, 2006, J HEART LUNG TRANSPL, V25, P1, DOI 10.1016/j.healun.2005.07.008
  • [8] Entwistle JWC, 2003, HEART SURG FORUM, V6, P316
  • [9] PROLONGED INTRAAORTIC BALLOON SUPPORT FOR SEPTAL RUPTURE AFTER MYOCARDIAL-INFARCTION
    ESTRADAQUINTERO, T
    URETSKY, BF
    MURALI, S
    HARDESTY, RL
    [J]. ANNALS OF THORACIC SURGERY, 1992, 53 (02) : 335 - 337
  • [10] Preoperative and postoperative comparison of patients with univentricular and biventricular support with the Thoratec ventricular assist device as a bridge to cardiac transplantation
    Farrar, DJ
    Hill, JD
    Pennington, DG
    McBride, LR
    Holman, WL
    Kormos, RL
    Esmore, D
    Gray, LA
    Seifert, PE
    Schoettle, GP
    Moore, CH
    Hendry, PJ
    Bhayana, JN
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1997, 113 (01) : 202 - 209