Robotic-assisted Unicompartmental Knee Arthroplasty: The MAKO Experience

被引:14
作者
Roche, Martin [1 ]
机构
[1] Holy Cross Orthoped Inst, Ft Lauderdale, FL 33334 USA
关键词
Unicompartmental knee arthroplasty; Robotic Assistance; MakoPlasty; Haptics; IN-VIVO KINEMATICS; REPLACEMENT; IMPLANT; UNICONDYLAR; ALIGNMENT; REVISION; SURGERY;
D O I
10.1016/j.ocl.2014.09.008
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Since its introduction, unicompartmental knee arthroplasty has been controversial because of poor early clinical outcomes due to implant design, bony fixation, surgical instrumentation, and technique. Improvements in surgical technique and implant design have resulted in improved results and greater survivorship. The ability to obtain accurate implant placement includes avoiding surgeon decisions leading to potential errors. These errors include alignment in the sagittal, corona!, and axial planes on each prepared condyle as well as the preservation of the joint line and the resulting overall limb alignment as something critical to obtaining a successful outcome.
引用
收藏
页码:125 / +
页数:8
相关论文
共 20 条
[1]   Early failure of unicompartmental knee arthroplasty leading to revision [J].
Aleto, Thomas J. ;
Berend, Michael E. ;
Ritter, Merrill A. ;
Faris, Philip M. ;
Meneghini, R. Michael .
JOURNAL OF ARTHROPLASTY, 2008, 23 (02) :159-163
[2]   Retrospective Analysis of Total Knee Arthroplasty Cases for Visual, Histological, and Clinical Eligibility of Unicompartmental Knee Arthroplasties [J].
Arno, Sally ;
Maffei, Diana ;
Walker, Peter S. ;
Schwarzkopf, Ran ;
Desai, Panna ;
Steiner, German C. .
JOURNAL OF ARTHROPLASTY, 2011, 26 (08) :1396-1403
[3]   Comparing in vivo kinematics of unicondylar and bi-unicondylar knee replacements [J].
Banks, SA ;
Fregly, BJ ;
Boniforti, F ;
Reinschmidt, C ;
Romagnoli, S .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2005, 13 (07) :551-556
[4]   Hands-on robotic unicompartmental knee replacement - A prospective, randomised controlled study of the Acrobot system [J].
Cobb, J ;
Henckel, J ;
Gomes, P ;
Harris, S ;
Jakopec, M ;
Rodriguez y Baena, F ;
Barrett, A ;
Davies, B .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (02) :188-197
[5]   Factors associated with the loss of thickness of polyethylene tibial bearings after knee arthroplasty [J].
Collier, Matthew B. ;
Engh, C. Anderson, Jr. ;
McAuley, James P. ;
Engh, Gerard A. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (06) :1306-1314
[6]   Patient, implant, and alignment factors associated with revision of medial compartment unicondylar arthroplasty [J].
Collier, Matthew B. ;
Eickmann, Thomas H. ;
Sukezaki, Fumio ;
McAuley, James P. ;
Engh, Gerard A. .
JOURNAL OF ARTHROPLASTY, 2006, 21 (06) :108-115
[7]  
Coon T, 2008, 21 C ISTA SACR CA
[8]  
Coon T m., 2010, J BONE JOINT SURG S1, V92-B, P157, DOI [10.1302/0301-620X.92BSUPP_I.0920157, DOI 10.1302/0301-620X.92BSUPP_I.0920157]
[9]   Accuracy of Dynamic Tactile-Guided Unicompartmental Knee Arthroplasty [J].
Dunbar, Nicholas J. ;
Roche, Martin W. ;
Park, Brian H. ;
Branch, Sharon H. ;
Conditt, Michael A. ;
Banks, Scott A. .
JOURNAL OF ARTHROPLASTY, 2012, 27 (05) :803-808
[10]   Implant position in knee surgery - A comparison of minimally invasive, open unicompartmental and total knee arthroplasty [J].
Fisher, DA ;
Watts, M ;
Davis, KE .
JOURNAL OF ARTHROPLASTY, 2003, 18 (07) :2-8