Performance Analysis of Voltage-Stateless Controller for Renewable-Energy-Supported Shunt-Active Power Filter

被引:7
作者
Ramakrishnan, C. [1 ]
Vijayan, S. [2 ]
机构
[1] SNS Coll Technol, Dept Elect & Elect Engn, Coimbatore 641035, Tamil Nadu, India
[2] Surya Engn Coll, Dept Elect & Elect Engn, Erode 638107, Tamil Nadu, India
关键词
photovoltaic system; second-order generalized integrator; shunt-active power filter; voltage-source inverter; total harmonic distortion; QUALITY CONDITIONER; REACTIVE POWER; 3-PHASE; STORAGE; SYSTEM; TIME;
D O I
10.1520/JTE20150509
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The shunt-active power filter (APF) is one of the most efficient solutions to power-quality issues. The topology has a parallel, connected voltage-source inverter, which offers compensation for current-based disturbances. The effectiveness of compensation is influenced by the control technique employed. Moreover, the controller decides the required quantity of sensors and measurement practices; therefore, it decides related costs. This study uses a second-order generalized integrator (SOGI) to extract the reference current of shunt APF. The proposed strategy uses only measuring of the converter and load currents, thereby does not require voltage measurement and sensors. The proposed topology uses the photovoltaic (PV) energy with an energy-storage unit to generally meet the active power requirement of the utility grid and provides the sustainable compensation of current disturbances and voltage interruption of the three-phase distribution system. The PV-supported shunt APF, tested with different types of loads, can evaluate the performance of the system under steady-state and dynamic conditions. To confirm the efficiency of the proposed controller for PV-supported shunt APF, the simulation and experimental results are presented.
引用
收藏
页码:953 / 966
页数:14
相关论文
共 25 条
[1]   New digital reference current generation for shunt active power filter under distorted voltage conditions [J].
Abdusalam, Mohamed ;
Poure, Philippe ;
Karimi, Shahram ;
Saadate, Shahrokh .
ELECTRIC POWER SYSTEMS RESEARCH, 2009, 79 (05) :759-765
[2]  
[Anonymous], 1992, IEEE Std. 519
[3]  
[Anonymous], 2011, ISGT 2011
[4]   Voltage Sensorless Control of Single-phase Active Power Filter Based on the Second-order Generalized Integrator Algorithm [J].
Biricik, Samet ;
Redif, Soydan ;
Basu, Malabika .
ELECTRIC POWER COMPONENTS AND SYSTEMS, 2015, 43 (07) :820-827
[5]   Real-time control of shunt active power filter under distorted grid voltage and unbalanced load condition using self-tuning filter [J].
Biricik, Samet ;
Redif, Soydan ;
Ozerdem, Ozgur C. ;
Khadem, Shafiuzzaman K. ;
Basu, Malabika .
IET POWER ELECTRONICS, 2014, 7 (07) :1895-1905
[6]  
Chang C., 2009, J TEST EVAL, V37, P1
[7]  
Charles S., 2010, INT J COMPUTER ELECT, V2, P175, DOI DOI 10.7763/IJCEE.2010.V2.132
[8]  
Chen GZ, 2004, APPL POWER ELECT CO, P587
[9]  
Fang Zheng Peng, 1998, IEEE Industry Applications Magazine, V4, P21, DOI 10.1109/2943.715502
[10]  
Goestan S, 2013, 4TH ANNUAL INTERNATIONAL POWER ELECTRONICS, DRIVE SYSTEMS & TECHNOLOGIES CONFERENCE (PEDSTC 2013), P510, DOI 10.1109/PEDSTC.2013.6506761