ATCA Fast Data Acquisition and Processing System for JET Gamma-Ray Cameras Upgrade Diagnostic

被引:1
|
作者
Pereira, R. C. [1 ]
Fernandes, A. M. [1 ]
Neto, A. [1 ]
Sousa, J. [1 ]
Batista, A. J. [1 ]
Carvalho, B. B. [1 ]
Correia, C. M. B. A. [2 ]
Varandas, C. A. F. [1 ]
机构
[1] Univ Tecn Lisboa, Inst Super Tecn, Assoc EURATOM, IST Inst Plasmas & Fusao Nucl, P-1049001 Lisbon, Portugal
[2] Univ Coimbra, EURATOM Assoc, IST Centro Elect & Instrumentacao, Dept Fis, P-3004516 Coimbra, Portugal
来源
2009 16TH IEEE-NPSS REAL TIME CONFERENCE | 2009年
关键词
Data Acquisition; Data Compression; Gamma-rays; Real time;
D O I
10.1109/RTC.2009.5321624
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
Nuclear reaction gamma-ray diagnosis is one of the important techniques used for studying confined fast-ions. The Joint European Torus (JET) gamma-ray camera diagnostic provides information on the spatial distribution of fast ions. The System is currently being upgraded and should allow gamma-ray image measurements in high power deuterium JET pulses, and eventually in deuterium-tritium discharges. In order to fully exploit the diagnostic capabilities it is mandatory to develop a reliable, maintainable, multi-channel spectroscopy data acquisition and real-time processing (DAQP) system, which shares Much of the common development for other specific implementation like Gamma-ray spectroscopy. The DAQP system is based on the Advanced Telecommunications Computing Architecture (ATCA) and contains a 6 GFLOPS x86-based control unit and three transient recorder and processing (TRP) modules, to cope with the two arrays of collimators (10 horizontal + 9 vertical lines of sight), interconnected through PCI Express (PCIc) links. Each TRP module features 8 channels of 13 bit resolution sampling at 250 MHz, 4GByte of local memory and two field programmable gate arrays able to perform complex trigger managing modes and allowing real time analyses (pulse height analyzer and pile-up discrimination), minimizing data storage and transfer issues. The DAQP system aims at overcoming the problem of storing large amount of data during long discharges. A raw/processed mode is being developed where the acquired raw data follows two parallel paths: besides being directly stored in the on-board memory, it is processed and streamed in real-time through PCIe links. This procedure is expected to greatly reduce the amount of data and possible allow continuous operation of the diagnostic. During commissioning and when data validation is required, the 4 GB raw data will be executed on the x86 control unit through a well known algorithm and the result cross checked with the processed data.
引用
收藏
页码:420 / +
页数:3
相关论文
共 28 条
  • [21] A dead-time-free data acquisition system for prompt gamma-ray measurements during proton therapy treatments
    Hueso-Gonzalez, Fernando
    Copado, Jose Vicente Casana
    Prieto, Antonio Fernandez
    Torreira, Abraham Gallas
    Cid, Edgar Lemos
    Garcia, Ana Ros
    Regueiro, Pablo Vazquez
    Llosa, Gabriela
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1033
  • [22] Design and Optimisation of a Three Layers Thermal Neutron, Fast Neutron and Gamma-Ray Imaging System
    Al Hamrashdi, H.
    Monk, S. D.
    Cheneler, D.
    ADVANCEMENTS IN NUCLEAR INSTRUMENTATION MEASUREMENT METHODS AND THEIR APPLICATIONS (ANIMMA 2019), 2020, 225
  • [23] Real-Time data acquisition Prototype proposal of the ITER radial neutron camera and gamma-ray spectrometer
    Pereira, R. C.
    Cruz, N.
    Fernandes, A.
    Sousa, J.
    Correia, C. M. B. A.
    Riva, M.
    Centioli, C.
    Marocco, D.
    Tardocchi, M.
    Nocente, M.
    Goncalves, B.
    Esposito, B.
    FUSION ENGINEERING AND DESIGN, 2017, 123 : 901 - 905
  • [24] Data processing and acquisition system for the HT-7 multipulse Thomson scattering diagnostic
    Chen, ZT
    Zhao, JY
    Fang, ZS
    Li, YD
    Yang, L
    PLASMA SCIENCE & TECHNOLOGY, 2003, 5 (04) : 1867 - 1872
  • [25] Data Processing and Acquisition System for the HT-7 Multipulse Thomson Scattering Diagnostic
    陈卓天
    赵君煜
    方自深
    李亚东
    杨利
    Plasma Science & Technology, 2003, (04) : 1867 - 1872
  • [26] Acquisition -: Analysis system for the DANCE (Detector for Advanced Neutron Capture Experiments) BaF2 gamma-ray calorimeter
    Wouters, JM
    Vicente, AA
    Bredeweg, TA
    Esch, E
    Haight, RC
    Hatarik, R
    O'Donnell, JM
    Reifarth, R
    Rundberg, RS
    Schwantes, JM
    Sheets, SA
    Ullmann, JL
    Vieira, DJ
    Wilhelmy, JB
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (03) : 880 - 885
  • [27] Study of environment friendly bismuth incorporated lithium borate glass system for structural, gamma-ray and fast neutron shielding properties
    Kaur, Parminder
    Singh, K. J.
    Kurudirek, Murat
    Thakur, Sonika
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2019, 223
  • [28] A Real-Time Data Acquisition and Processing Framework Based on FlexRIO FPGA and ITER Fast Plant System Controller
    Yang, C.
    Zheng, W.
    Zhang, M.
    Yuan, T.
    Zhuang, G.
    Pan, Y.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2016, 63 (03) : 1715 - 1719