Endoscopic ultrasound-guided fine-needle marking of lymph nodes

被引:5
作者
Larsen, M. H. [1 ]
Fristrup, C. W. [1 ]
Pless, T. [1 ]
Ainsworth, A. P. [1 ]
Nielsen, H. O. [1 ]
Hovendal, C. P. [1 ]
Mortensen, M. B. [1 ]
机构
[1] Odense Univ Hosp, Ctr Surg Ultrasound, Dept Surg, DK-5000 Odense, Denmark
关键词
POSITRON-EMISSION-TOMOGRAPHY; ESOPHAGEAL-CARCINOMA; PREOPERATIVE LOCALIZATION; LUNG-CANCER; EUS; ASPIRATION; ULTRASONOGRAPHY; ACCURACY; LYMPHADENOPATHY; METAANALYSIS;
D O I
10.1055/s-0029-1215378
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and study aims: No previous studies have evaluated the ability of endoscopic ultrasonography to describe the anatomic location of lymph nodes on the basis of a node-to-node comparison. The aim of this study was to assess the feasibility and safety of a new endoscopic ultrasound (EUS)-guided fine-needle technique for marking lymph nodes. Patients and methods: Twenty-five patients with suspected or confirmed malignancies of the upper gastrointestinal tract were prospectively included. EUS-guided fine-needle marking (EUS-FNM) was performed with a silver pin with a diameter that allowed it to fit into a 19-gauge needle. The position of the pin was verified by EUS. End points were the ability to identify and isolate the marked lymph node during surgery and a comparison between the location of the pin as suggested by EUS and the actual location found in the resected specimen. Results: Twenty-three lymph nodes were marked. Nineteen intended surgical isolations were performed. The lymph nodes were isolated in the resection specimens in 18 patients (95%). In 2 out of 20 cases the pin was not localized by laparoscopic ultrasonography. In 89% of the cases the marked lymph node was in the same location as described by EUS. One pin (5%) was not retrieved. In three cases, a small hematoma was observed. There was no sign of long-term complications. Conclusion: EUS-FNM with a silver pin in lymph nodes is feasible and safe. EUS-FNM seems to be a suitable tool for evaluating lymph nodes on the basis of a node-to-node comparison.
引用
收藏
页码:133 / 137
页数:5
相关论文
共 50 条
[31]   Pancreatic Schwannoma Diagnosed by Endoscopic Ultrasound-guided Fine-needle Aspiration [J].
Hanaoka, Taro ;
Okuwaki, Kosuke ;
Imaizumi, Hiroshi ;
Imawari, Yusuke ;
Iwai, Tomohisa ;
Yamauchi, Hiroshi ;
Hasegawa, Rikiya ;
Adachi, Kai ;
Tadehara, Masayoshi ;
Kurosu, Takahiro ;
Watanabe, Masafumi ;
Tamaki, Akihiro ;
Kida, Mitsuhiro ;
Koizumi, Wasaburo .
INTERNAL MEDICINE, 2021, 60 (09) :1389-1395
[32]   Delayed peritonitis after endoscopic ultrasound-guided fine-needle aspiration of a metastatic celiac lymph node [J].
Cartana, T. ;
Saftoiu, A. ;
Popescu, C. ;
Gheonea, D. I. ;
Ciurea, T. ;
Georgescu, I. .
ENDOSCOPY, 2011, 43 :E122-E123
[33]   A Comparison of Endoscopic Ultrasound-Guided Fine-Needle Aspiration and Fine-Needle Biopsy in the Diagnosis of Solid Pancreatic Lesions [J].
Ayres, Lachlan R. ;
Kmiotek, Elizabeth K. ;
Lam, Eric ;
Telford, Jennifer J. .
CANADIAN JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2018, 2018
[34]   Endoscopic ultrasound-guided fine-needle aspiration vs fine-needle biopsy for the diagnosis of pancreatic neuroendocrine tumors [J].
Eusebi, Leonardo H. ;
Thorburn, Douglas ;
Toumpanakis, Christos ;
Frazzoni, Leonardo ;
Johnson, Gavin ;
Vessal, Sheida ;
Tu Vinh Luong ;
Caplin, Martyn ;
Pereira, Stephen P. .
ENDOSCOPY INTERNATIONAL OPEN, 2019, 7 (11) :E1393-E1399
[35]   The Chef Has a Knife. Endoscopic Ultrasound-Guided Fine-Needle Aspiration by a Pulmonologist [J].
Mehta, Atul C. ;
Cicenia, Joseph ;
Yasufuku, Kazuhiro .
CHEST, 2015, 147 (05) :1201-1203
[36]   Sudden appearance of free fluid during endoscopic ultrasound-guided fine-needle aspiration [J].
Rimbas, Mihai ;
Deaconu, Marian ;
Croitoru, Alexandru ;
Haidar, Andrei .
ENDOSCOPIC ULTRASOUND, 2016, 5 (01) :55-57
[37]   Endoscopic ultrasound-guided fine-needle aspiration for the diagnosis of extra-pulmonary tuberculosis [J].
Berzosa, M. ;
Tsukayama, D. T. ;
Davies, S. F. ;
Debol, S. M. ;
Cen, Y-Y. ;
Li, R. ;
Mallery, S. .
INTERNATIONAL JOURNAL OF TUBERCULOSIS AND LUNG DISEASE, 2010, 14 (05) :578-584
[38]   Diagnostic accuracy of endoscopic ultrasound-guided fine-needle aspiration for pancreatic cancer: A meta-analysis [J].
Chen, Ge ;
Liu, Shanglong ;
Zhao, Yupei ;
Dai, Menghua ;
Zhang, Taiping .
PANCREATOLOGY, 2013, 13 (03) :298-304
[39]   Accuracy of ultrasound-guided fine-needle aspiration for small cervical lymph nodes: A retrospective review of 505 cases [J].
Fu, Ying ;
Liu, Chang ;
Ren, Minglei ;
Du, Tingting ;
Wang, Yihua ;
Mei, Fang ;
Cui, Ligang .
HELIYON, 2024, 10 (10)
[40]   Comparative Study of an Ultrasound-guided Percutaneous Biopsy and Endoscopic Ultrasound-guided Fine-needle Aspiration for Liver Tumors [J].
Takano, Yuichi ;
Noda, Jun ;
Yamawaki, Masataka ;
Azami, Tetsushi ;
Kobayashi, Takahiro ;
Niiya, Fumitaka ;
Maruoka, Naotaka ;
Norose, Tomoko ;
Ohike, Nobuyuki ;
Wakabayashi, Tetsuji ;
Matsuo, Kenichi ;
Tanaka, Kuniya ;
Nagahama, Masatsugu .
INTERNAL MEDICINE, 2021, 60 (11) :1657-1664