Effect of casting technique on surface roughness and consequent mass loss after polishing of NiCr and CoCr base metal alloys: A comparative study with titanium

被引:45
作者
Bezzon, OL [1 ]
Pedrazzi, H [1 ]
Zaniquelli, O [1 ]
da Silva, TBC [1 ]
机构
[1] Univ Sao Paulo, Ribeirao Preto Sch Dent, Dept Dent Mat & Prostheses, Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
D O I
10.1016/j.prosdent.2004.04.021
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Surface roughness of cast metal frameworks may lead to difficulties in finishing or polishing procedures and weaken the framework. Purpose. The aim of this study was to assess the surface roughness of 2 base metal alloys, submitted to different casting techniques, to determine the influence of surface roughness on loss of mass after polishing compared to commercially pure titanium castings. Material and methods. Forty disk-shaped wax patterns (8 X 2 mm) were randomly assigned to 5 groups (n=8): (1) CoCr alloy (Wironit), acetylene-oxygen flame casting (WFC), (2) NiCr alloy (Verabond II), acetylene-oxygen flame casting (VFC), (3) CoCr alloy, vacuum casting (WVC), (4) NiCr alloy, vacuum casting (VVC), and (5) commercially pure Ti alloy (Ti) melted by electric arc in argon gas atmosphere. WFC and VFC served as controls. Both NiCr and CoCr alloys were invested in phosphate-bonded investment (Termocast). Ti was invested in ammonium dihydrogen phosphate (Rematitam Plus). The wax patterns and casting techniques were standardized. All specimens were cleaned with airborne-particle abrasion (aluminum oxide). Surface roughness (Ra) was assessed using a surface-test analyzer at 3 different sites. To evaluate the loss of mass, the specimens were weighed on a precision balance, then polished with 150-600 grain sandpaper until clinically acceptable (minimum roughness of 0.09 mum). The specimens were then reweighed. A 1-way analysis of variance (ANOVA) and Tukey HSD test (alpha=.05) were performed. Results. Statistical analysis showed that VVC and WVC had significantly (P=.0050; P=.0057) smoother surfaces (2.43 +/- 0.53 and 2.23 +/- 0.49, respectively) than VFC and WFC (2.99 +/- 0.44 and 2.83 +/- 0.61, respectively), but were not significantly different from Ti (2.49 +/- 0.62). The loss of mass (in %) was not significantly different for any group (3.18 +/- 0.72, 3.14 +/- 0.93, 3.36 +/- 1.05%, and 4.14 +/- 1.28% for VVC, WVC, VFC, and WFC, respectively). The mass loss of Ti was 4.32 +/- 1.16. Conclusion. Within the limitations of this study, the base metal alloys submitted to vacuum casting showed decreased surface roughness, similar to that of titanium, compared to base metal alloys submitted to acetylene-oxygen flame casting. There were no significant differences in loss of mass after polishing for all tested specimens.
引用
收藏
页码:274 / 277
页数:4
相关论文
共 26 条
  • [1] AYDIN AK, 1991, J PROSTHET DENT, V65, P763
  • [2] Comparison of surface roughness of oral hard materials to the threshold surface roughness for bacterial plaque retention: A review of the literature
    Bollen, CML
    Lambrechts, P
    Quirynen, M
    [J]. DENTAL MATERIALS, 1997, 13 (04) : 258 - 269
  • [3] Surface quality achieved by polishing and by varnishing of temporary crown and fixed partial denture resins
    Borchers, L
    Tavassol, F
    Tschernitschek, H
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1999, 82 (05) : 550 - 556
  • [4] Comparison of titanium and cobalt-chromium removable partial denture clasps
    Bridgeman, JT
    Marker, VA
    Hummel, SK
    Benson, BW
    Pace, LL
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1997, 78 (02) : 187 - 193
  • [5] THE TOOTH-REMOVABLE PARTIAL DENTURE INTERFACE
    BRUDVIK, JS
    REIMERS, D
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1992, 68 (06) : 924 - 927
  • [6] CUNNINGHAM DM, 1973, DENT CLIN N AM, V17, P719
  • [7] RADIOGRAPHIC AND METALLOGRAPHIC EVALUATION OF POROSITY DEFECTS AND GRAIN-STRUCTURE OF CAST CHROMIUM COBALT REMOVABLE PARTIAL DENTURES
    DHARMAR, S
    RATHNASAMY, RJ
    SWAMINATHAN, TN
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1993, 69 (04) : 369 - 373
  • [8] Fatigue resistance of cast occlusal rests using Co-Cr and Ag-Pd-Cu-Au alloys
    Gapido, CG
    Kobayashi, H
    Miyakawa, O
    Kohno, S
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2003, 90 (03) : 261 - 269
  • [9] Plaque formation on surface modified dental implants -: An in vitro study
    Grössner-Schreiber, B
    Griepentrog, MH
    Haustein, I
    Müller, WD
    Lange, KP
    Briedigkeit, H
    Göbel, UB
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2001, 12 (06) : 543 - 551
  • [10] Comparison of castability and surface roughness of commercially pure titanium and cobalt-chromium denture frameworks
    Jang, KS
    Youn, SJ
    Kim, YS
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2001, 86 (01) : 93 - 98