Seismic behavior of bidirectional bolted connections for CFT columns and H-beams

被引:76
作者
Wu, Lai-Yun [1 ]
Chung, Lap-Loi
Tsai, Sheng-Fu
Lu, Chien-Fan
Huang, Guo-Luen
机构
[1] Natl Taiwan Univ, Dept Civil Engn, Taipei 106, Taiwan
[2] Natl Taiwan Univ, Natl Ctr Res Earthquake Engn, Taipei 106, Taiwan
关键词
seismic behavior; concrete-filled tube (CFT); bidirectional bolted beam-to-column connection; earthquake resistance;
D O I
10.1016/j.engstruct.2006.05.007
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Concrete-filled tubes (CFTs) have the advantages of both steel tubes and concrete. For that the confinement of the steel tube on the concrete would enhance the stiffness, strength and ductility of the concrete; also, the filled concrete can decrease the possibility of inward buckling of the steel. In this paper, bidirectional bolted beam-to-column connections for CFTs are proposed. A mechanical model is established to derive theoretical equations for calculating the stiffness, the yielding shear strength and ultimate shear strength of the panel zone. Also, a series of cyclic loading experiments has been conducted to verify it. The experimental results demonstrate that the bidirectional bolted connections have superior earthquake resistance in stiffness, strength, ductility and energy dissipation mechanism. These results indicate that the seismic resistance exceeds those specified in the seismic design codes of Taiwan and the US. Therefore, the bidirectional bolted beam-to-column connection has excellent seismic resistance, and this structural system can perform well as expected and be put into practice. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:395 / 407
页数:13
相关论文
共 15 条
[1]   Analytical behavior of connections to concrete-filled steel tubes [J].
Alostaz, YM ;
Schneider, SP .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 1996, 40 (02) :95-127
[2]  
Alostaz YM, 1996, P 11 WORLD C EARTHQ
[3]   DESIGN OF THROUGH BEAM CONNECTION DETAIL FOR CIRCULAR COMPOSITE COLUMNS [J].
AZIZINAMINI, A ;
SHEKAR, Y ;
SAADEGHVAZIRI, MA .
ENGINEERING STRUCTURES, 1995, 17 (03) :209-213
[4]   Design provisions for connections between steel beams and concrete filled tube columns [J].
Elremaily, A ;
Azizinamini, A .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2001, 57 (09) :971-995
[5]  
FUJIMOTO T, 1997, 4 JTCC
[6]  
FUJIMOTO T, P 6 INT C STEEL CONC
[7]  
FURLONG RW, 1968, J STRUCTURAL DIVISIO, V94, P267
[8]   Hysteresis behavior of CFT column to H-beam connections with external T-stiffeners and penetrated elements [J].
Kang, CH ;
Shin, KJ ;
Oh, YS ;
Moon, TS .
ENGINEERING STRUCTURES, 2001, 23 (09) :1194-1201
[9]  
KRAWINKLER H, 1978, ENG J AISC, V15, P82
[10]   Design of steel MRF connections before and after 1994 Northridge earthquake [J].
Popov, EP ;
Yang, TS ;
Chang, SP .
ENGINEERING STRUCTURES, 1998, 20 (12) :1030-1038