Modified CCF Based Shunt Active Power Filter Operation With Dead-Band Elimination for Effective Harmonic and Unbalance Compensation in 3-Phase 3-Wire System

被引:22
作者
Dubey, Alok Kumar [1 ]
Mishra, Jyoti Prakash [1 ]
Kumar, Amritesh [1 ]
机构
[1] Natl Inst Technol, Dept Elect Engn, Silchar 788010, India
关键词
Power harmonic filters; Harmonic analysis; Active filters; Switches; Power filters; Voltage control; Filtering theory; Shunt active power filter (SAPF); dead band elimination; dual fundamental component extraction (DFCE); modified CCF (MCCF); TIME ELIMINATION; VOLTAGE;
D O I
10.1109/TPWRD.2021.3104828
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The effect of reduction in the terminal voltage of a grid-tied inverter together with minimization in total harmonic distortion (THD) of terminal voltage and current, in the presence of dead-band in the switching remains always challenging for the researchers. With high switching frequency, this issue increases by many folds. The grid-tied inverter used for harmonic compensation acts as a shunt active power filter (SAPF). The implementation of the dead-band elimination technique is based on output current polarity detection, suffers from multiple zero-crossing due to the generation of high frequency switching harmonics during SAPF operation. This paper deals with a dead band elimination methodology together with harmonic compensation using SAPF under non-linear and unbalanced loading conditions. Here, SAPF uses a dual fundamental component extraction (DFCE) scheme with modified complex coefficient filter (MCCF) to extract fundamental components for reference current generation to implement an indirect current control PWM scheme. MCCF extracts fundamental components even in the presence of dc offset and unbalancing at the input. For incorporating dead-band elimination in control, exact polarity detection is done separately through SAPF output current estimation using sensed load current, and modified CCF computed reference source current. Since the estimated SAPF output current contains no high-frequency switching harmonics, the dead-band elimination technique can be correctly implemented. To synchronize the zero-crossing of the estimated and actual SAPF current, an adaptive delay control is used. The proposed MCCF based control logic's performance together with the dead-band elimination technique is validated for SAPF operating under non-linear, unbalance, and dynamic load conditions. The proposed dead-band elimination scheme based SAPF model is developed and simulated using MATLAB/ SIMULINK. The simulation results show a significant reduction in source current harmonics due to the elimination of odd harmonic injection into the system by incorporating dead-band elimination in SAPF operation. The real-time simulation of the proposed method is also validated using OPAL-RT OP4510 real-time platform.
引用
收藏
页码:2131 / 2142
页数:12
相关论文
共 23 条
[1]   New trends in active filters for power conditioning [J].
Akagi, H .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1996, 32 (06) :1312-1322
[2]   Control and operation of a solar PV-battery-grid-tied system in fixed and variable power mode [J].
Beniwal, Neha ;
Hussain, Ikhlaq ;
Singh, Bhim .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2018, 12 (11) :2633-2641
[3]   Real-time control of shunt active power filter under distorted grid voltage and unbalanced load condition using self-tuning filter [J].
Biricik, Samet ;
Redif, Soydan ;
Ozerdem, Ozgur C. ;
Khadem, Shafiuzzaman K. ;
Basu, Malabika .
IET POWER ELECTRONICS, 2014, 7 (07) :1895-1905
[4]   Dead-time elimination for voltage source inverters [J].
Chen, Lihua ;
Peng, Fang Zheng .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2008, 23 (02) :574-580
[5]  
Fang Zheng Peng, 1998, IEEE Industry Applications Magazine, V4, P21, DOI 10.1109/2943.715502
[6]   A Study on Three-Phase FLLs [J].
Golestan, Saeed ;
Guerrero, Josep M. ;
Vasquez, Juan C. ;
Abusorrah, Abdullah M. ;
Al-Turki, Yusuf .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2019, 34 (01) :213-224
[7]   Operation of Three-Level Inverter-Based Shunt Active Power Filter Under Nonideal Grid Voltage Conditions With Dual Fundamental Component Extraction [J].
Hoon, Yap ;
Radzi, Mohd Amran Mohd ;
Hassan, Mohd Khair ;
Mailah, Nashiren Farzilah .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2018, 33 (09) :7558-7570
[8]   Control Strategies of Mitigating Dead-time Effect on Power Converters: An Overview [J].
Ji, Yi ;
Yang, Yong ;
Zhou, Jiale ;
Ding, Hao ;
Guo, Xiaoqiang ;
Padmanaban, Sanjeevikumar .
ELECTRONICS, 2019, 8 (02)
[9]   Shunt active power filter: Current status of control techniques and its integration to renewable energy sources [J].
Kumar, Ravinder ;
Bansal, Hari Om .
SUSTAINABLE CITIES AND SOCIETY, 2018, 42 :574-592
[10]   Dead-Time Elimination of PWM-Controlled Inverter/Converter Without Separate Power Sources for Current Polarity Detection Circuit [J].
Lin, Yong-Kai ;
Lai, Yen-Shin .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (06) :2121-2127