Optimal color channel combination across skin tones for remote heart rate measurement in camera-based photoplethysmography

被引:9
作者
Ernst, Hannes [1 ,2 ]
Scherpf, Matthieu [2 ]
Malberg, Hagen [2 ]
Schmidt, Martin [2 ]
机构
[1] Tech Univ Dresden, Res Training Grp Conduc Design Cyber Phys Prod Sy, Dresden, Germany
[2] Tech Univ Dresden, Inst Biomed Engn, Dresden, Germany
关键词
Imaging photoplethysmography; Color channel combination; Color space transformation; Heart rate; Region of interest;
D O I
10.1016/j.bspc.2021.102644
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: The heart rate is an essential vital sign that can be measured remotely with camera-based photoplethysmography (cbPPG). Systems for cbPPG typically use cameras that deliver red, green, and blue (RGB) channels. The combination of these channels has been proven to increase signal-to-noise ratio (SNR) and heart rate measurement accuracy (ACC). However, many combinations remain untested, the comparison of proposed combinations on large datasets is insufficiently investigated, and the interplay with skin tone is rarely addressed. Methods: Eight regions of interest and eight color spaces with a total of 25 color channels were compared in terms of ACC and SNR based on the Binghamton-Pittsburgh-RPI Multimodal Spontaneous Emotion Database (BP4D+). Additionally, two systematic grid searches were performed to evaluate ACC in the space of linear combinations of the RGB channels. Results: Glabella and forehead regions of interest provided highest ACC (up to 74.1 %) and SNR (> -3 dB) with the hue channel H from HSV color space and the chrominance channel Q from NTSC color space. The grid searches revealed a global optimum of linear RGB combinations (ACC: 79.2 %). This optimum occurred for all skin tones, although ACC dropped for darker skin tones. Conclusion: Through systematic grid searches we were able to identify the skin tone independent optimal linear RGB color combination for measuring heart rate with cbPPG. Our results proved on a large dataset that the identified optimum outperformed conventionally used color channels. Significance: The presented findings provide useful evidence for future considerations of algorithmic approaches for cbPPG.
引用
收藏
页数:10
相关论文
共 28 条
  • [1] [Anonymous], 2004, 170M2004 SMPTE, DOI [10.5594/S9781614823353, DOI 10.5594/S9781614823353]
  • [2] [Anonymous], 2017, BILDVERARBEITUNG MED, DOI DOI 10.1007/978-3-662-54345-0_16
  • [3] Antink Christoph Hoog, 2019, Yearb Med Inform, V28, P102, DOI 10.1055/s-0039-1677914
  • [4] Telemedicine Technology: a Review of Services, Equipment, and Other Aspects
    Baker, John
    Stanley, Anthony
    [J]. CURRENT ALLERGY AND ASTHMA REPORTS, 2018, 18 (11)
  • [5] Optical properties of human skin, subcutaneous and mucous tissues in the wavelength range from 400 to 2000 nm
    Bashkatov, AN
    Genina, EA
    Kochubey, VI
    Tuchin, VV
    [J]. JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2005, 38 (15) : 2543 - 2555
  • [6] Automatic Selection of Webcam Photoplethysmographic Pixels Based on Lightness Criteria
    Bousefsaf, Frederic
    Maaoui, Choubeila
    Pruski, Alain
    [J]. JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2017, 37 (03) : 374 - 385
  • [7] Ambient and unobtrusive cardiorespiratory monitoring techniques
    Brüser, Christoph
    Antink, Christoph Hoog
    Wartzek, Tobias
    Walter, Marian
    Leonhardt, Steffen
    [J]. IEEE Reviews in Biomedical Engineering, 2015, 8 : 30 - 43
  • [8] Improved motion robustness of remote-PPG by using the blood volume pulse signature
    de Haan, G.
    van Leest, A.
    [J]. PHYSIOLOGICAL MEASUREMENT, 2014, 35 (09) : 1913 - 1926
  • [9] Robust Pulse Rate From Chrominance-Based rPPG
    de Haan, Gerard
    Jeanne, Vincent
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (10) : 2878 - 2886
  • [10] More Reliable Remote Heart Rate Measurement by Signal Quality Indexes
    Ernst, Hannes
    Malberg, Hagen
    Schmidt, Martin
    [J]. 2020 COMPUTING IN CARDIOLOGY, 2020,