Background Modem-generation metal-on-metal articulations have a high wear resistance and may therefore be able to improve the long-term performance of artificial joints. However, the biological effects are still under debate. This study was undertaken to review the histopathological changes in neo-capsule tissues of different metal-on-metal hip arthroplasties. Methods Neo-capsule tissue samples from 46 hips with modem second-generation metal-on-metal articulations (39 hip resurfacings and 7 non-cemented total hip replacements) with a variety of failure mechanisms were examined histopathologically and immunohistochemically. Results A distinct lymphocytic infiltration was found in all cases with in situ times of more than 7 months, consisting of CD20-positive B-lymphocytes and CD3-positive T-lymphocytes and sometimes thinly distributed CD138-positive plasma cells without dominant T-cell or plasma cell infiltrates. Interpretation This distinct lymphocytic infiltration has not been reported in tissue analyses of metal- or ceramic-on-polyethylene hip replacements, and may therefore be considered to be a characteristic histological pattern of tissue reactions on metal particles and/or ions around metal-on-metal bearings.
引用
收藏
页码:211 / 220
页数:10
相关论文
共 60 条
[51]   Intolerance of osteosynthesis material:: evidence of dichromate contact allergy with concomitant oligoclonal T-cell infiltrate and TH1-type cytokine expression in the peri-implantar tissue [J].
Thomas, P ;
Summer, B ;
Sander, CA ;
Przybilla, B ;
Thomas, M ;
Naumann, T .
ALLERGY, 2000, 55 (10) :969-972
[52]   Birmingham hip resurfacing arthroplasty - A minimum follow-up of five years [J].
Treacy, RBC ;
McBryde, CW ;
Pynsent, PB .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (02) :167-170
[53]   PROSTHETIC IMPLANT REACTIONS [J].
VERNONROBERTS, B .
AUSTRALIAN AND NEW ZEALAND JOURNAL OF MEDICINE, 1978, 8 :159-162
[54]  
Wagner M, 2000, CLIN ORTHOP RELAT R, P123
[55]  
WAGNER M, 1996, CLIN ORTHOP S, V329, P78
[56]   REACTIONS OF ARTICULAR CAPSULE TO WEAR PRODUCTS OF ARTIFICIAL JOINT PROSTHESES [J].
WILLERT, HG ;
SEMLITSCH, M .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1977, 11 (02) :157-164
[57]   Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints - A clinical and histomorphological study [J].
Willert, HG ;
Buchhorn, GH ;
Fayyazi, A ;
Flury, R ;
Windler, M ;
Koster, G ;
Lohmann, CH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (01) :28-36
[58]  
Willert HG, 1996, CLIN ORTHOP RELAT R, P4
[59]  
Willert HG, 2001, WORLD TRIBOLOGY FORU, P147
[60]  
Witzleb WCC, 2004, ORTHOPADE, V33, P1236, DOI 10.1007/s00132-004-0718-0