Performance of the Fourier rebinning algorithm for PET with large acceptance angles

被引:42
作者
Matej, S [1 ]
Karp, JS [1 ]
Lewitt, RM [1 ]
Becher, AJ [1 ]
机构
[1] Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
关键词
D O I
10.1088/0031-9155/43/4/008
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The recently proposed Fourier rebinning (FORE) technique of 3D PET reconstruction is investigated over a wide range of axial acceptance angles. In this study we evaluate the performance of the FORE technique using spatial resolution, contrast and noise figures of merit and compare reconstruction performance of the FORE (followed by multislice 2D reconstruction) to the 3D-RP technique for large-acceptance-angle data (+/-26.25 degrees). Our results show that the FORE technique does not affect the transverse resolution. On the other hand the axial resolution using FORE deteriorates faster, compared with the 3D-RP, at large radii as the acceptance angle increases. Concerning the noise behaviour, we have found that filtering has better ability to suppress the noise in the FORE reconstruction, compared with the 3D-RP reconstruction, especially in the slices near the edge of the axial field of view. Overall, the combination of good performance and fast reconstruction time makes the FORE technique a practical choice for 3D PET applications.
引用
收藏
页码:787 / 795
页数:9
相关论文
共 13 条
  • [1] DAUBEWITHERSPOON ME, 1987, J NUCL MED, V28, P1717
  • [2] Exact and approximate rebinning algorithms for 3-D PET data
    Defrise, M
    Kinahan, PE
    Townsend, DW
    Michel, C
    Sibomana, M
    Newport, DF
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (02) : 145 - 158
  • [3] Defrise M., 1995, Proceedings of the 1995 International Meeting on Fully Three-Dimensional Image Reconstruction in Radiology and Nuclear Medicine, P235
  • [4] A FACTORIZATION METHOD FOR THE 3D X-RAY TRANSFORM
    DEFRISE, M
    [J]. INVERSE PROBLEMS, 1995, 11 (05) : 983 - 994
  • [5] DEFRISE M, 1995, P 1995 IEEE NUCL SCI, V3, P1316
  • [6] Edholm P. R., 1986, Proceedings of the SPIE - The International Society for Optical Engineering, V671, P8, DOI 10.1117/12.966672
  • [7] 3D RECONSTRUCTION FOR A MULTIRING PET SCANNER BY SINGLE-SLICE REBINNING AND AXIAL DECONVOLUTION
    ERLANDSSON, K
    ESSER, PD
    STRAND, SE
    VANHEERTUM, RL
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (03) : 619 - 629
  • [8] Karp JS, 1997, J NUCL MED, V38, P636
  • [9] A comparison of transform and iterative reconstruction techniques for a volume-imaging PET scanner with a large axial acceptance angle
    Kinahan, PE
    Matej, S
    Karp, JS
    Herman, GT
    Lewitt, RM
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (06) : 2281 - 2287
  • [10] ANALYTIC 3D IMAGE-RECONSTRUCTION USING ALL DETECTED EVENTS
    KINAHAN, PE
    ROGERS, JG
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) : 964 - 968