Influence of bone architecture on the primary stability of different mini-implant designs

被引:21
作者
da Cunha, Amanda Carneiro [1 ]
Marquezan, Mariana [1 ]
Lima, Inaya [2 ]
Lopes, Ricardo Tadeu [2 ]
Nojima, Lincoln Issamu [1 ]
Sant'Anna, Eduardo Franzotti [1 ]
机构
[1] Univ Fed Rio de Janeiro, Dept Pedodont & Orthodont, BR-21941617 Rio De Janeiro, RJ, Brazil
[2] Univ Fed Rio de Janeiro, Nucl Instrumentat Lab, Nucl Engn Program, BR-21941617 Rio De Janeiro, RJ, Brazil
关键词
MINISCREW IMPLANTS; ORTHODONTIC ANCHORAGE; COMPUTED-TOMOGRAPHY; DENSITY; SCREWS; STRENGTH; QUALITY; TORQUE; IMPACT;
D O I
10.1016/j.ajodo.2014.09.011
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: Mechanical interlocking between a mini-implant (MI) and the bone substrate reflects directly on the primary stability achieved. The purposes of this study were to evaluate MI design performance in distinct bone substrates and correlate geometric characteristics with insertion site quality. Methods: Two types of self-drilling MIs (1.6 x 8 mm) were allocated to 2 groups according to their geometric designs: Tomas system (Dentaurum, Ispringen, Germany) and Dual-Top (Rocky Mountain Orthodontics, Denver, Colo). Forty sections (8 x 10 mm) were taken from bovine pelvic ilium and pubic bone. Geometric design characteristics were evaluated using scanning electron microscope imaging and Image-Pro Insight software (Media Cybernetics, Rockville, Md). Bone quality parameters were assessed with a microcomputed tomography system, and primary stability was evaluated by insertion torque and pull-out strength. Intergroup comparisons were performed with analysis of variance and Tukey tests, and the Pearson correlation test was carried out (P < 0.05). Results: No significant difference was observed in the comparisons of the groups (Tomas: insertion torque, 12.87 N.cm; pull-out strength, 181 N; and Dual-Top: insertion torque, 9.95 N.cm; pull-out strength, 172.5 N) in the ilium. However, the Tomas group had a marked increase in insertion torque (25.08 N.cm; P < 0.05) in the pubic bone. Conclusions: MI mechanical performance differed according to bone quality parameters, indicating that certain geometric parameters may be set depending on the insertion substrate.
引用
收藏
页码:45 / 51
页数:7
相关论文
共 38 条
  • [1] [Anonymous], 2007, 543 ASTM, P20
  • [2] Temporary skeletal anchorage devices: The case for miniscrews
    Baumgaertel, Sebastian
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2014, 145 (05) : 558 - 564
  • [3] A NEW DEVICE FOR ABSOLUTE ANCHORAGE FOR ORTHODONTICS
    BLOCK, MS
    HOFFMAN, DR
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1995, 107 (03) : 251 - 258
  • [4] Pitch and Longitudinal Fluting Effects on the Primary Stability of Miniscrew Implants
    Brinley, Christine L.
    Behrents, Rolf
    Kim, Ki Beom
    Condoor, Sridhar
    Kyung, Hee-Moon
    Buschang, Peter H.
    [J]. ANGLE ORTHODONTIST, 2009, 79 (06) : 1156 - 1161
  • [5] Miniscrew stability evaluated with computerized tomography scanning
    Cha, Jung-Yul
    Kil, Jae-Kyoung
    Yoon, Tae-Min
    Hwang, Chung-Ju
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 137 (01) : 73 - 79
  • [6] Effects of thread depth, taper shape, and taper length on the mechanical properties of mini-implants
    Chang, Jenny Zwei-Chieng
    Chen, Yi-Jane
    Tung, Yuan-Yi
    Chiang, Yu-Ying
    Lai, Eddie Hsiang-Hua
    Chen, Weng-Pin
    Lin, Chun-Pin
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2012, 141 (03) : 279 - 288
  • [7] Factors affecting the pullout strength of cancellous bone screws
    Chapman, JR
    Harrington, RM
    Lee, KM
    Anderson, PA
    Tencer, AF
    Kowalski, D
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1996, 118 (03): : 391 - 398
  • [8] Costa A, 1998, Int J Adult Orthodon Orthognath Surg, V13, P201
  • [9] Creekmore T D, 1983, J Clin Orthod, V17, P266
  • [10] The use of small titanium screws for orthodontic anchorage
    Deguchi, T
    Takano-Yamamoto, T
    Kanomi, R
    Hartsfield, JK
    Roberts, WE
    Garetto, LP
    [J]. JOURNAL OF DENTAL RESEARCH, 2003, 82 (05) : 377 - 381