Renal cysts: Is attenuation artifactually increased on contrast-enhanced CT images?

被引:67
作者
Bae, KT [1 ]
Heiken, JP [1 ]
Siegel, CL [1 ]
Bennett, HF [1 ]
机构
[1] Washington Univ, Sch Med, Mallinckrodt Inst Radiol, St Louis, MO 63110 USA
关键词
computed tomography (CT); contrast enhancement; helical; kidney; CT; cysts;
D O I
10.1148/radiology.216.3.r00se14792
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To determine if the attenuation values of simple renal cysts are artifactually increased on contrast material-enhanced, clinically acquired spiral computed tomographic (CT) images. MATERIALS AND METHODS: Dual-phase renal spiral CT studies (5-mm collimation; pitch, 1.0) were retrospectively analyzed in 24 consecutive patients who had ultrasonographic (US) documentation of simple renal cysts. Forty-eight cysts were identified. The attenuation values of each cyst were measured on nonenhanced, cortical phase, and nephrographic phase images. The size and the location of each cyst in relation to the renal parenchyma were also recorded. RESULTS: The cysts were 0.6-10.8 cm in diameter (mean, 2.6 cm; SD, 2.0). The mean attenuation change in the cysts from nonenhanced to contrast-enhanced images was statistically significant in a comparison of cortical phase and nephrographic phase images (P < .01): +1.8 HU (SD, 3.8) for cortical phase and +3.6 HU (SD, 5.6) for nephrographic phase images. Renal cysts 1.0 cm or smaller showed a higher attenuation increase (mean, +4.0 HU for cortical phase and +11.0 HU for nephrographic phase). None of the renal cysts larger than 1.0 cm demonstrated an increase greater than 10 HU (mean, +1.4 HU for cortical phase and +2.3 HU for nephrographic phase). Intraparenchymal cysts showed higher mean attenuation changes than the exophytic cysts. CONCLUSION: Attenuation Values in the renal cysts increased artifactually on contrast-enhanced images, but this pseudoenhancement was not substantial and was less than 10 HU when the cyst was larger than 1.0 cm in diameter.
引用
收藏
页码:792 / 796
页数:5
相关论文
共 50 条
  • [41] Contrast-enhanced ultrasonography:: renal applications
    Correas, JM
    Claudon, M
    Tranquart, F
    Hélénon, O
    JOURNAL DE RADIOLOGIE, 2003, 84 (12): : 2041 - 2054
  • [42] RENAL STREAK ARTIFACT DURING CONTRAST-ENHANCED CT - COMPARISON OF LOW VERSUS HIGH OSMOLALITY CONTRAST-MEDIA
    SUSSMAN, SK
    ILLESCAS, FF
    OPALACZ, JP
    YIRGA, P
    FOLEY, LC
    ABDOMINAL IMAGING, 1993, 18 (02): : 180 - 185
  • [43] Effect of radiographic contrast material exposure on spiral CT attenuation of renal calculi
    Monga, AG
    Saw, C
    Williams, JC
    Fineberg, NS
    McAteer, JA
    Lingeman, JE
    Chua, GT
    ACADEMIC RADIOLOGY, 2001, 8 (10) : 982 - 986
  • [44] Usefulness of contrast-enhanced ultrasonography in the diagnosis of renal pseudotumors
    Silvio Mazziotti
    Fabrizio Zimbaro
    Alessia Pandolfo
    Sergio Racchiusa
    Nicola Settineri
    Giorgio Ascenti
    Abdominal Imaging, 2010, 35 : 241 - 245
  • [45] The role of contrast-enhanced ultrasound in the classification of CT-indeterminate renal lesions
    Edenberg, Jan
    Gloersen, Kaja
    Osman, Herzi Abdi
    Dimmen, Magne
    Berg, Geir V.
    SCANDINAVIAN JOURNAL OF UROLOGY, 2016, 50 (06) : 445 - 451
  • [46] Contrast-enhanced Ultrasound of Renal Masses
    Bennett, Jack
    Peterson, Cynthia
    Barr, Richard G.
    APPLIED RADIOLOGY, 2020, 49 (06) : 10 - 16
  • [47] Multiphase contrast-enhanced CT with highly concentrated contrast agent can be used for PET attenuation correction in integrated PET/CT imaging
    Philip Aschoff
    Christian Plathow
    Thomas Beyer
    Matthias P. Lichy
    Gunter Erb
    Mehmet Ö. Öksüz
    Claus D. Claussen
    Christina Pfannenberg
    European Journal of Nuclear Medicine and Molecular Imaging, 2012, 39 : 316 - 325
  • [48] Automatic vessel attenuation measurement for quality control of contrast-enhanced CT: Validation on the portal vein
    McCoy, Kevin
    Marisetty, Sujay
    Tan, Dominique
    Jensen, Corey T.
    Siewerdsen, Jeffrey H.
    Peterson, Christine B.
    Ahmad, Moiz
    MEDICAL PHYSICS, 2024, : 5954 - 5964
  • [49] Follow-Up After Percutaneous Radiofrequency Ablation of Renal Cell Carcinoma: Contrast-Enhanced Sonography Versus Contrast-Enhanced CT or MRI
    Meloni, Maria Franca
    Bertolotto, Michele
    Alberzoni, Chiara
    Lazzaroni, Sergio
    Filice, Carlo
    Livraghi, Tito
    Ferraioli, Giovanna
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (04) : 1233 - 1238
  • [50] Multiphase contrast-enhanced CT with highly concentrated contrast agent can be used for PET attenuation correction in integrated PET/CT imaging
    Aschoff, Philip
    Plathow, Christian
    Beyer, Thomas
    Lichy, Matthias P.
    Erb, Gunter
    Oeksuez, Mehmet Oe.
    Claussen, Claus D.
    Pfannenberg, Christina
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 (02) : 316 - 325