Influence of gravity on radiographic contrast material-based measurements of regional blood flow distribution

被引:8
作者
Clough, AV [1 ]
Haworth, ST
Roerig, DL
Hoffman, EA
Dawson, CA
机构
[1] Marquette Univ, Dept Math Stat & Comp Sci, Milwaukee, WI 53233 USA
[2] Marquette Univ, Dept Biomed Engn, Milwaukee, WI 53233 USA
[3] Med Coll Wisconsin, Dept Physiol, Milwaukee, WI 53226 USA
[4] Med Coll Wisconsin, Dept Anesthesiol, Milwaukee, WI 53226 USA
[5] Zablocki Vet Adm Med Ctr, Clin Physiol Res Serv 151, Milwaukee, WI 53295 USA
[6] Univ Iowa, Dept Radiol, Roy J & Lucille A Carver Coll Med, Iowa City, IA USA
关键词
angiography; computed tomography (CT); multi-detector row; perfusion study; contrast media; lung; perfusion;
D O I
10.1016/S1076-6332(03)80036-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. Radiographic measurement of regional blood flow distribution in the lungs is potentially biased because the contrast material used to track flow is denser than blood. The authors performed this study to evaluate I the effect of gravity on flow estimates by using an experimental test phantom and numeric simulations. Materials and Methods. Cross-sectionally uniform boluses of radiopaque contrast material were delivered at the upstream end of a horizontal inlet tube connected to a downstream axisymmetric bifurcation attached to collecting tubing spirals. The phantom was imaged by using both planar angiography and dynamic multi-detector row computed tomography (CT) during the passage of the bolus through the phantom. The images were analyzed to determine the relative amounts of contrast material traveling through the top and bottom branches of the bifurcation by using varying Reynolds numbers and ratios of inlet tube volume to bolus volume. Numeric simulations of flow within a straight channel, with use of a dispersion operator intended to simulate settling of the bolus due to gravity, were performed under conditions representative of those in the experiments. Results. When the plane of the bifurcation was vertical and actual flow through the two branches was equal, the fraction of contrast material passing through the downward-directed branch increased with decreasing Reynolds number and increasing inlet tube-bolus volume ratio. This occurred in both the experiments and the simulations. Conclusion. Because in the circulation Reynolds number decreases and pathway length increases with decreasing vessel diameter, the accuracy of regional flow measurements obtained with angiography or CT within the lungs may be limited by density differences between contrast material and blood.
引用
收藏
页码:128 / 138
页数:11
相关论文
共 17 条
[1]   PULMONARY CAPILLARY TRANSPORT FUNCTION FROM FLOW-LIMITED INDICATORS [J].
AUDI, SH ;
KRENZ, GS ;
LINEHAN, JH ;
RICKABY, DA ;
DAWSON, CA .
JOURNAL OF APPLIED PHYSIOLOGY, 1994, 77 (01) :332-351
[2]  
BASSINGTHWAIGHT.JB, 1993, NUCL CARDIOLOGY STAT, P3
[3]   MODEL-FREE DECONVOLUTION TECHNIQUES FOR ESTIMATING VASCULAR TRANSPORT FUNCTIONS [J].
BRONIKOWSKI, TA ;
DAWSON, CA ;
LINEHAN, JH .
INTERNATIONAL JOURNAL OF BIO-MEDICAL COMPUTING, 1983, 14 (05) :411-429
[4]   Transit time dispersion in the pulmonary arterial tree [J].
Clough, AV ;
Haworth, ST ;
Hanger, CC ;
Wang, J ;
Roerig, DL ;
Linehan, JH ;
Dawson, CA .
JOURNAL OF APPLIED PHYSIOLOGY, 1998, 85 (02) :565-574
[5]   REGIONAL TRANSIT-TIME ESTIMATION FROM IMAGE RESIDUE CURVES [J].
CLOUGH, AV ;
ALTINAWI, A ;
LINEHAN, JH ;
DAWSON, CA .
ANNALS OF BIOMEDICAL ENGINEERING, 1994, 22 (02) :128-143
[6]   Regional perfusion parameters from pulmonary microfocal angiograms [J].
Clough, AV ;
Linehan, JH ;
Dawson, CA .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1997, 272 (03) :H1537-H1548
[7]   Effects of hypoxia on pulmonary microvascular volume [J].
Clough, AV ;
Haworth, ST ;
Ma, W ;
Dawson, CA .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2000, 279 (03) :H1274-H1282
[8]   HEPATIC PERFUSION ABNORMALITIES DURING CT ANGIOGRAPHY - DETECTION AND INTERPRETATION [J].
FREENY, PC ;
MARKS, WM .
RADIOLOGY, 1986, 159 (03) :685-691
[9]   MATCHING PULMONARY STRUCTURE AND PERFUSION VIA COMBINED DYNAMIC MULTISLICE CT AND THIN-SLICE HIGH-RESOLUTION CT [J].
HOFFMAN, EA ;
TAJIK, JK ;
KUGELMASS, SD .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1995, 19 (01) :101-112
[10]   Assessment of the pulmonary structure-function relationship and clinical outcomes measures: Quantitative volumetric CT of the lung [J].
Hoffman, EA ;
McLennan, G .
ACADEMIC RADIOLOGY, 1997, 4 (11) :758-776