Insights on the Degradation and Performance of 3000 Photovoltaic Installations of Various Technologies Across the United Kingdom

被引:17
作者
Dhimish, Mahmoud [1 ]
Schofield, Nigel [1 ]
Attya, Ayman [1 ]
机构
[1] Univ Huddersfield, Dept Engn & Technol, Huddersfield HD1 3DH, W Yorkshire, England
关键词
Degradation; Temperature measurement; II-VI semiconductor materials; Cadmium compounds; Silicon; Filtering; Estimation; Cumulative density function (CDF) function; degradation rate; performance analysis; photovoltaic (PV) systems; PV technologies; LONG-TERM EXPOSURE; MODULES; RATES; RELIABILITY;
D O I
10.1109/TII.2020.3022762
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This article presents the degradation rates over 8 years for 3000 photovoltaic (PV) installations distributed across the U.K. The article considers three PV cell technologies, namely, monocrystalline silicon (Mono-Si), polycrystalline silicon (Poly-Si), and thin-film cadmium telluride (CdTe). The available raw data undergoes three key stages: normalization, filtering, and aggregation, before the degradation analysis of the considered installations. This algorithm can be considered as one of the article contributions. Results show that a maximum degradation rate of -1.43%/year is observed for the CdTe type, whereas Poly-Si and Mono-Si PVs have annual degradation rates of -0.94% and -0.81%, respectively. Moreover, this article exploits the monthly mean performance ratio (PR) for all the examined PV sites. The highest PR value of 87.97% is calculated for the Mono-Si PV installations, while 85.08% and 83.55% are calculated for Poly-Si and CdTe installations, respectively.
引用
收藏
页码:5919 / 5926
页数:8
相关论文
共 37 条
[1]  
Abenante L, 2018, WORL CON PHOTOVOLT E, P1155, DOI 10.1109/PVSC.2018.8548234
[2]   Analysis of inhomogeneous local distribution of potential induced degradation at a rooftop photovoltaic installation [J].
Buerhop, Claudia ;
Pickel, Tobias ;
Patel, Tirth ;
Fecher, Frank W. ;
Zetzmann, Cornelia ;
Camus, Christian ;
Hauch, Jens ;
Brabec, Christoph J. .
IET RENEWABLE POWER GENERATION, 2017, 11 (10) :1253-1260
[3]   Influence of pre-existing damages on the degradation behavior of crystalline silicon photovoltaic modules [J].
Camus, Christian ;
Adegbenro, Ayodeji ;
Ermer, Jakob ;
Suryaprakash, Vignesh ;
Hauch, Jens ;
Brabec, Christoph J. .
JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2018, 10 (02)
[4]   DC-side fault detection for photovoltaic energy conversion system using fractional-order dynamic-error-based fuzzy Petri net integrated with intelligent meters [J].
Chen, Jian-Liung ;
Kuo, Chao-Lin ;
Chen, Shi-Jaw ;
Kao, Chih-Cheng ;
Zhan, Tung-Sheng ;
Lin, Chia-Hung ;
Chen, Ying-Shin .
IET RENEWABLE POWER GENERATION, 2016, 10 (09) :1318-1327
[5]   Performance Ratio and Degradation Rate Analysis of 10-Year Field Exposed Residential Photovoltaic Installations in the UK and Ireland [J].
Dhimish, Mahmoud .
CLEAN TECHNOLOGIES, 2020, 2 (02) :170-183
[6]   Thermal impact on the performance ratio of photovoltaic systems: A case study of 8000 photovoltaic installations [J].
Dhimish, Mahmoud .
CASE STUDIES IN THERMAL ENGINEERING, 2020, 21
[7]   Photovoltaic Degradation Rate Affected by Different Weather Conditions: A Case Study Based on PV Systems in the UK and Australia [J].
Dhimish, Mahmoud ;
Alrashidi, Abdullah .
ELECTRONICS, 2020, 9 (04)
[8]   Exploratory evaluation of solar radiation and ambient temperature in twenty locations distributed in United Kingdom [J].
Dhimish, Mahmoud ;
Mather, Peter .
URBAN CLIMATE, 2019, 27 :179-192
[9]   CDF modelling for the optimum tilt and azimuth angle for PV installations: case study based on 26 different locations in region of the Yorkshire UK [J].
Dhimish, Mahmoud ;
Mather, Peter ;
Holmes, Violeta ;
Sibley, Martin .
IET RENEWABLE POWER GENERATION, 2019, 13 (03) :399-408
[10]   Evaluating Power Loss and Performance Ratio of Hot-Spotted Photovoltaic Modules [J].
Dhimish, Mahmoud ;
Mather, Peter ;
Holmes, Violeta .
IEEE TRANSACTIONS ON ELECTRON DEVICES, 2018, 65 (12) :5419-5427