Comparison of capillary electrophoresis and reversed-phase liquid chromatography methodologies for determination of diazepam in pharmaceutical tablets

被引:29
作者
Prado, MSA
Steppe, M
Tavares, MFM
Kedor-Hackmann, ERM
Santoro, MIRM
机构
[1] Univ Sao Paulo, Fac Pharmaceut Sci, Dept Pharm, BR-05508900 Sao Paulo, Brazil
[2] Univ Sao Paulo, Inst Chem, BR-05599970 Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
capillary electrophoresis; diazepam; reversed-phase liquid chromatography;
D O I
10.1016/j.jpba.2004.10.026
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two novel analytical methodologies using capillary electrophoresis (CE) and reversed-phase high-performance liquid chromatography (RPHPLC) for the determination of diazepam in commercial and simulated tablet formulations were developed and compared. The CE analysis was carried out in a bare fused-silica capillary with 75 mum i.d. and total length of 50 cm (28 cm to the detector) with a buffer solution containing 20 mmol L-1 sodium tetraborate and 20 mmol L-1 sodium dodecylsulfate (SDS), pH 9.23. The applied voltage was 20 kV and bromazepam was used as internal standard (IS). The RP-HPLC analysis was carried out in a LiChrospher(R) 100 RP-18 (5 mum) column with a mobile phase constituted of methanol, acetonitrile and water (45:25:30) with a flow rate of 0.8 mL/min, using acetaminophen as IS. In both cases, detection was carried out by ultraviolet (UV) absorption at 242 nm. Under the optimized conditions, the CE retention times for the standard diazepam and bromazepam (IS) were 4.08 and 3.43 min, respectively, and the retention times of the RP-HPLC analysis for the standard diazepam and acetaminophen (IS) were 4.86 and 1.58 min, respectively. The resolution and efficiency for CE were 7.4 and 1.18 x 10(5) plates/m and for RP-HPLC, 7.5 and 1.76 x 10(4) plates/m. Analytical curves of peak area versus concentration presented correlation coefficients of 0.9996 for CE and 0.9994 for RP-HPLC. The limits of detection (LOD) and quantitation (LOQ) were 4.24 and 12.85 mug/mL for CE and 1.44 and 4.36 mug/mL for RP-HPLC. Relative standard deviations (R.S.D.) were 1.62 and 0.98% for CE and RP-HPLC, respectively. The percentage recovery determined with CE was 100.27 +/- 1.25 and with RP-HPLC was 101.12 +/- 2.48. Although both methodologies were shown to be suitable for the determination of diazepam in tablets, performing in a similar manner with regards to several aspects (linearity, recovery and specificity), CE provided a faster analysis and column efficiency whereas RP-HPLC presented a superior repeatability and sensitivity. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:273 / 279
页数:7
相关论文
共 28 条
[1]   Chromatographic method for the determination of diazepam, pyridostigmine bromide, and their metabolites in rat plasma and urine [J].
Abu-Qare, AW ;
Abou-Donia, MB .
JOURNAL OF CHROMATOGRAPHY B, 2001, 754 (02) :503-509
[2]  
ALTRIA KD, 1996, METHODS MOL BIOL SER, V52, P64
[3]   Rapid and simple chromatographic method for the determination of diazepam and its major metabolites in human plasma and urine [J].
Azzam, RM ;
Notarianni, LJ ;
Ali, HM .
JOURNAL OF CHROMATOGRAPHY B, 1998, 708 (1-2) :304-309
[4]   Quantitative determination of diazepam, nitrazepam and flunitrazepam in tablets using thin-layer chromatography-densitometry technique [J].
Bakavoli, M ;
Kaykhaii, M .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 31 (06) :1185-1189
[5]  
BOLTON S, 1990, PHARM STAT PRACTICAL, P27
[6]   Influence of ionic strength and organic modifier on performance in capillary electrochromatography on phenyl silica stationary phase [J].
Cahours, X ;
Morin, P ;
Dreux, M .
JOURNAL OF CHROMATOGRAPHY A, 1999, 845 (1-2) :203-216
[7]   Direct injection micellar liquid chromatographic determination of benzodiazepines in serum [J].
Capella-Peiró, ME ;
Bose, D ;
Martinavarro-Domínguez, A ;
Gil-Agustí, M ;
Esteve-Romero, J .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 780 (02) :241-249
[8]   Screening for forensically relevant benzodiazepines in human hair by gas chromatography negative ion chemical ionization mass spectrometry [J].
Cirimele, V ;
Kintz, P ;
Ludes, B .
JOURNAL OF CHROMATOGRAPHY B, 1997, 700 (1-2) :119-129
[9]  
GARFIELD FM, 1991, QUALITY ASSURANCE PR, P74
[10]  
GOODMAN LS, 1991, MED PANAMERICANA, P305