Femoroplasty - augmentation of the proximal femur with a composite bone cement - feasibility, biomechanical properties and osteosynthesis potential

被引:65
作者
Beckmann, J.
Ferguson, S. J.
Gebauer, A.
Luering, C.
Gasser, B.
Heini, P.
机构
[1] Univ Regensburg, Orthopaed Clin & Policlin, Asklepios Klin Bad Abbach, D-93077 Bad Abbach, Germany
[2] Univ Bern, MEM Res Ctr, Inst Surg Technol & Biomech, Bern, Switzerland
[3] R Mathys RMS, Bettlach, Switzerland
[4] Univ Bern, Inselspital, Dept Orthoped Surg, CH-3010 Bern, Switzerland
关键词
hip; fracture; osteoporosis; cement; reinforcement; augmentation; femoroplasty;
D O I
10.1016/j.medengphy.2006.08.006
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Analogous to vertebroplasty, cement-augmentation of the proximal femur ("femoroplasty") could reinforce osteoporotic bones. This study was to evaluate (i) the feasibility of femoroplasty with a composite cement (Cortoss (TM)), (ii) its influence on femoral strength by mechanical testing and (iii) the feasibility of stable osteosynthesis of the augmented fractured bones. Methods: Nine human cadaveric femora were augmented with a composite bone cement, the surface heat generation monitored, and then tested biomechanically against their native contralateral control to determine fracture strength. Subsequently, thirteen reinforced and fractured femora were osteosynthetized by different implants and tested against their osteosynthetisized, non-augmented contralateral control. Findings: Cement could be injected easily, with a moderate temperature rise. A positive correlation between BMD and fracture load and a significant increase in fracture load (+43%) of the augmented femora compared to their native controls (6324N and 4430N, respectively) as well as a significant increase in energy-to-failure (+ 187%, 86 N m and 30 N m, respectively) was found. Osteosynthesis was possible in cement-augmented femora. Osteosynthetisized femora showed equivalent strength to the intact controls. Interpretation: Augmentation of the proximal femur with composite bone cement could be of use in prophylaxis of fractures in osteoporotic femurs. Osteosynthesis of the fractured augmented bones is a challenging procedure but has a good chance to restore strength. (C) 2006 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:755 / 764
页数:10
相关论文
共 62 条
[1]   A modified hip screw incorporating injected cement for the fixation of osteoporotic trochanteric fractures [J].
Augat, P ;
Rapp, S ;
Claes, L .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2002, 16 (05) :311-316
[2]   THE EFFECT OF ADJUNCTIVE METHYLMETHACRYLATE ON FAILURES OF FIXATION AND FUNCTION IN PATIENTS WITH INTERTROCHANTERIC FRACTURES AND OSTEOPOROSIS [J].
BARTUCCI, EJ ;
GONZALEZ, MH ;
COOPERMAN, DR ;
FREEDBERG, HI ;
BARMADA, R ;
LAROS, GS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1985, 67A (07) :1094-1107
[3]  
Berlemann U, 2002, UNFALLCHIRURG, V105, P1, DOI 10.1007/s113-002-8156-y
[4]  
Bonnaire FA, 2002, INJURY, V33, pS47
[5]   Norian SRS cement compared with conventional fixation in distal radial fractures - A randomized study [J].
Cassidy, C ;
Jupiter, JB ;
Cohen, M ;
Delli-Santi, M ;
Fennell, C ;
Leinberry, C ;
Husband, J ;
Ladd, A ;
Seitz, WR ;
Constanz, B .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (11) :2127-2137
[6]  
Cauley J. A., 2002, Journal of Musculoskeletal & Neuronal Interactions, V2, P220
[7]   Bone mineral density and the risk of incident nonspinal fractures in black and white women [J].
Cauley, JA ;
Lui, LY ;
Ensrud, KE ;
Zmuda, JM ;
Stone, KL ;
Hochberg, MC ;
Cummings, SR .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2005, 293 (17) :2102-2108
[8]  
CLAES L, 1995, UNFALLCHIRURG, V98, P118
[9]  
COBEY JC, 1976, CLIN ORTHOP RELAT R, P258
[10]   EFFECTS OF LOADING RATE ON STRENGTH OF THE PROXIMAL FEMUR [J].
COURTNEY, AC ;
WACHTEL, EF ;
MYERS, ER ;
HAYES, WC .
CALCIFIED TISSUE INTERNATIONAL, 1994, 55 (01) :53-58