Reduced graphene oxide supported MXene based metal oxide ternary composite electrodes for non-enzymatic glucose sensor applications

被引:15
|
作者
Gopal, Tamil Selvi [1 ]
Alzahrani, Khalid E. [2 ,3 ]
Assaifan, Abdulaziz K. [2 ]
Albrithen, Hamad [2 ,3 ]
Alodhayb, Abdullah [2 ,3 ]
Muthuramamoorthy, Muthumareeswaran [2 ]
Pandiaraj, Saravanan [4 ]
Grace, Andrews Nirmala [1 ]
机构
[1] Vellore Inst Technol, Ctr Nanotechnol Res, Vellore, Tamil Nadu, India
[2] King Saud Univ, King Abdullah Inst Nanotechnol, Biol & Environm Sensing Res Unit, POB 2455, Riyadh 11451, Saudi Arabia
[3] King Saud Univ, Coll Sci, Dept Phys & Astron, Riyadh 11451, Saudi Arabia
[4] King Saud Univ, Dept Selfdev Skills, CFY Deanship, Riyadh, Saudi Arabia
关键词
SUPERCAPACITOR; ARCHITECTURES; ARRAYS;
D O I
10.1038/s41598-022-24700-w
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Diagnosis and monitoring of glucose level in human blood has become a prime necessity to avoid health risk and to cater this, a sensor's performance with wide linearity range and high sensitivity is required. This work reports the use of ternary composite viz. MG-Cu2O (rGO supported MXene sheet with Cu2O) for non-enzymatic sensing of glucose. It has been prepared by co-precipitation method and characterized with X-ray powder diffraction, Ultraviolet-visible absorption spectroscopy (UV-Vis), Raman spectroscopy, Field emission scanning electron microscopy, High resolution transmission electron microscopy and Selected area diffraction. These analyses show a cubic structure with spherical shaped Cu2O grown on the MG sheet. Further, the electrocatalytic activity was carried out with MG-Cu2O sensing element by cyclic voltammetry and chronoamperometry technique and compared with M-Cu2O (MXene with Cu2O) composite without graphene oxide. Of these, MG-Cu2O composite was having the high defect density with lower crystalline size of Cu2O, which might enhance the conductivity thereby increasing the electrocatalytic activity towards the oxidation of glucose as compared to M-Cu2O. The prepared MG-Cu2O composite shows a sensitivity of 126.6 mu AmM-1 cm(-2) with a wide linear range of 0.01to 30 mM, good selectivity, good stability over 30 days and shows a low Relative Standard Deviation (RSD) of 1.7% value towards the sensing of glucose level in human serum. Thus, the aforementioned finding indicates that the prepared sensing electrode is a well suitable candidate for the sensing of glucose level for real time applications.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Copper/reduced graphene oxide film modified electrode for non-enzymatic glucose sensing application
    Sopit Phetsang
    Pinit Kidkhunthod
    Narong Chanlek
    Jaroon Jakmunee
    Pitchaya Mungkornasawakul
    Kontad Ounnunkad
    Scientific Reports, 11
  • [42] Non-enzymatic electronic detection of glucose using aminophenylboronic acid functionalized reduced graphene oxide
    Vasu, K. S.
    Sridevi, S.
    Sampath, S.
    Sood, A. K.
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 221 : 1209 - 1214
  • [43] Nanostructured nickel oxide electrodes for non-enzymatic electrochemical glucose sensing
    Natasha Singer
    Rajesh G. Pillai
    Aliesha I. D. Johnson
    Kenneth D. Harris
    Abebaw B. Jemere
    Microchimica Acta, 2020, 187
  • [44] Nanostructured nickel oxide electrodes for non-enzymatic electrochemical glucose sensing
    Singer, Natasha
    Pillai, Rajesh G.
    Johnson, Aliesha I. D.
    Harris, Kenneth D.
    Jemere, Abebaw B.
    MICROCHIMICA ACTA, 2020, 187 (04)
  • [45] A non-enzymatic amperometric hydrogen peroxide sensor based on iron nanoparticles decorated reduced graphene oxide nanocomposite
    Amanulla, Baishnisha
    Palanisamy, Selvakumar
    Chen, Shen-Ming
    Velusamy, Vijayalakshmi
    Chiu, Te-Wei
    Chen, Tse-Wei
    Ramaraj, Sayee Kannan
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2017, 487 : 370 - 377
  • [46] Copper Oxide Decorated Zinc Oxide Nanostructures for the Production of a Non-Enzymatic Glucose Sensor
    Cheng, Chung-En
    Tangsuwanjinda, Sripansuang
    Cheng, Hsin-Ming
    Lee, Po-Han
    COATINGS, 2021, 11 (08)
  • [47] Highly sensitive and reusable Cu+2/polyaniline/reduced graphene oxide nanocomposite ink-based non-enzymatic glucose sensor
    Anand, Vijay Kumar
    Bukke, Archana
    Bhatt, Kapil
    Kumar, Sandeep
    Sharma, Sandeep
    Goyal, Rakesh
    Virdi, G. S.
    APPLIED PHYSICS A-MATERIALS SCIENCE & PROCESSING, 2020, 126 (07):
  • [48] Novel One Pot Synthesis of Alkaline-reduced Iron Oxide/graphene Nanocomposites for Amperometric Non-enzymatic Glucose Sensor
    Suyanta
    Yazid, Siti Nur Akmar Mohd
    Isa, Illyas Md
    Hashim, Norhayati
    Ahmad, Mohamad Syahrizal
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (09): : 9200 - 9213
  • [49] Pt-CuO nanoparticles decorated reduced graphene oxide for the fabrication of highly sensitive non-enzymatic disposable glucose sensor
    Dhara, Keerthy
    Stanley, John
    Ramachandran, T.
    Nair, Bipin G.
    Babu, Satheesh T. G.
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 195 : 197 - 205
  • [50] Highly sensitive and reusable Cu+2/polyaniline/reduced graphene oxide nanocomposite ink-based non-enzymatic glucose sensor
    Vijay Kumar Anand
    Archana Bukke
    Kapil Bhatt
    Sandeep Kumar
    Sandeep Sharma
    Rakesh Goyal
    G. S. Virdi
    Applied Physics A, 2020, 126