Micellar liquid chromatography (MLC) has been used primarily for the separation of neutral analytes of varying polarities, most commonly phenols and polyaromatic hydrocarbons, but does not seem to have been used to study aromatic hydroxy acids in detail. We have studied the separation of hydroxybenzoic acid mixtures, including monohydroxybenzoic and dihydroxybenzoic acid positional isomers by MLC. Sodium dodecylsulfate (SDS) is investigated as the modifying surfactant on a C18 ultra-high performance liquid chromatography (UHPLC) column (100 x 2.1 mm, 1.8 mu m). The addition of only SDS (no organic solvent) to the mobile phase reduced the influence of hydrophobic interactions while improving the retention times, resolution, and peak shapes, even at concentrations below the critical micellization concentration (CMC). The UHPLC separation of 7 hydroxybenzoic acids, including 6 dihydroxybenzoic acid positional isomers and one trihydroxybenzoic acid, is achieved with high efficiency using 0.1% SDS in 1.84 mM sulfuric acid (pH 2.43) mobile phase, in less than 6 min with a flow rate of 0.3 mL min(-1), and in less than four min with a flow rate of 0.7 mL min(-1). Six monohydroxybenzoic acid isomers are also effectively separated by MLC, using a 0.5% SDS mobile phase modifier, in less than 20 min with a flow rate of 0.3 mL min(-1), and in less than 14 min with a flow rate of 0.7 mL min(-1). The 3 phthalic acid isomers could be separated using a similar mobile phase and flow rates in less than 6 and 4 min. Solute micelle equilibrium constants and partition coefficients are calculated for 6 monohydroxybenzoic acids based on a plot of MLC retention factor vs. mobile phase micelle concentration. All aromatic acid isomers studied can be classified as binding solutes in the MLC retention mechanism. Less effective separations are observed with shorter chain surfactants, leading to higher retention times and poor peak shapes. It is concluded that increasing chain length led to more efficient MLC separations, and SDS is the preferred modifying surfactant for the examined separation. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:150 / 159
页数:10
相关论文
共 38 条
[31]   Phenolic acids in foods: An overview of analytical methodology [J].
Robbins, RJ .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2003, 51 (10) :2866-2887
[32]   Reversed-phase liquid chromatography with mixed micellar mobile phases of Brij-35 and sodium dodecyl sulphate: a method for the analysis of basic compounds [J].
Ruiz-Angel, M. J. ;
Peris-Garcia, E. ;
Garcia-Alvarez-Coque, M. C. .
GREEN CHEMISTRY, 2015, 17 (06) :3561-3570
[33]   Performance of different C18 columns in reversed-phase liquid chromatography with hydro-organic and micellar-organic mobile phases [J].
Ruiz-Angel, M. J. ;
Pous-Torres, S. ;
Carda-Broch, S. ;
Garcia-Alvarez-Coque, M. C. .
JOURNAL OF CHROMATOGRAPHY A, 2014, 1344 :76-82
[34]   Submicellar and micellar reversed-phase liquid chromatographic modes applied to the separation of β-blockers [J].
Ruiz-Angel, M. J. ;
Torres-Lapasio, J. R. ;
Garcia-Alvarez-Coque, M. C. ;
Carda-Broch, S. .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (15) :3199-3209
[35]   Retention mechanisms in micellar liquid chromatography [J].
Ruiz-Angel, M. J. ;
Carda-Broch, S. ;
Torres-Lapasio, J. R. ;
Garcia-Alvarez-Coque, M. C. .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (10) :1798-1814
[36]   Analysis of phenolic compounds by high performance liquid chromatography and ultra performance liquid chromatography [J].
Spacil, Zdenek ;
Novakova, Lucie ;
Solich, Petr .
TALANTA, 2008, 76 (01) :189-199
[37]   DETERMINATION OF SUN-SCREEN AGENTS IN COSMETIC PRODUCTS BY MICELLAR LIQUID-CHROMATOGRAPHY [J].
TOMASELLA, FP ;
PAN, ZT ;
LOVE, LJC .
JOURNAL OF CHROMATOGRAPHY, 1991, 587 (02) :325-328
[38]   EFFECTS OF RESTRICTED MASS-TRANSFER ON THE EFFICIENCY OF MICELLAR CHROMATOGRAPHY [J].
YARMCHUK, P ;
WEINBERGER, R ;
HIRSCH, RF ;
LOVE, LJC .
JOURNAL OF CHROMATOGRAPHY, 1984, 283 (JAN) :47-60