An isotope dilution liquid chromatography-tandem mass spectrometry candidate reference measurement procedure for aldosterone measurement in human plasma

被引:6
|
作者
Zhang, Qiaoxuan [1 ,2 ]
Han, Liqiao [1 ]
Zheng, Songbai [3 ]
Ouyang, Fen [1 ]
Wu, Xiaobin [1 ]
Yan, Jun [1 ]
Zhan, Min [1 ]
Ke, Peifeng [1 ]
Zhuang, Junhua [1 ]
Huang, Xianzhang [1 ]
机构
[1] Guangzhou Univ Chinese Med, Affiliated Hosp 2, Dept Lab Med, Guangzhou 510120, Guangdong, Peoples R China
[2] Guangzhou Univ Chinese Med, Clin Med Coll 2, Guangzhou 510120, Guangdong, Peoples R China
[3] Fujian Huayin Med Lab Ctr, Xiamen 361101, Fujian, Peoples R China
关键词
Aldosterone; Reference measurement procedure; Tandem mass spectrometry; Clinical laboratory measurements;
D O I
10.1007/s00216-021-03405-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Accurate quantitation of aldosterone is clinically important in standardized testing for primary aldosteronism. The results are often variable when performed by clinical immunoassays. To standardize and ensure the accuracy of clinical systems, reference measurement procedures (RMPs) with higher metrological order are required. A simple and reliable isotope dilution LC-IDMS/MS-based measurement procedure for human plasma aldosterone has been developed. This method involved plasma spiked with a deuterium-labelled internal standard, equilibrated for 0.5 h, and extracted by liquid-liquid extraction (LLE) without derivatization. Aldosterone and its structural analogues were baseline separated with a C18-packed UHPLC column with gradient elution within 7 min. The signal intensity variability and measurement imprecision were reduced by bracketing calibration during plasma aldosterone value assignment. The limit of detection (LoD) was 19.4 pmol/L with a signal-to-noise ratio (S/N) > 3. The lowest limit of quantification (LLoQ) was 27.7 pmol/L (S/N > 10 and CV < 10.0%). LLE was performed with 1 mL of n-hexane/ethyl acetate (3:2, v/v), and the extraction recovery was determined to be 92.15 +/- 3.54%. The imprecisions were <= 3.18% for samples at 124.8, 867.0, and 2628.5 pmol/L. The recoveries were 98.11-101.61%. The relative bias between this candidate RMP and the established RMP was 2.76-1.89%. The linearity response ranged from 27.7 to 2774.4 pmol/L with R-2 = 0.999. The method performance met the requirements of RMPs (<= 5% total CV and <= 3% bias). Furthermore, the developed method was applied to evaluate immunoassays through 41 patient sample comparisons. The calibration and measurement capability (CMC) of this method were also evaluated by measuring these samples. The candidate RMP can serve as an accurate reference baseline for routine methods and can be used for value assignment for reference materials.
引用
收藏
页码:4471 / 4481
页数:11
相关论文
共 50 条
  • [41] Development of a matrix-based candidate reference material for human glycated albumin using isotope-dilution liquid chromatography/tandem mass spectrometry
    Zhang, Rui
    Zhao, Rui
    Ren, Wenhua
    Wang, Mo
    Fan, Gaowei
    Shi, Jie
    Song, Yichuan
    Zhou, Xiaojie
    Wang, Qingtao
    ANALYTICA CHIMICA ACTA, 2023, 1239
  • [42] Identification, Measurement, and Assessment of the Clinical Utility of Human Pancreatic Polypeptide by Liquid Chromatography-Tandem Mass Spectrometry
    Maus, Anthony
    Fatica, Erica M.
    Taylor, Robert
    Larson, Bethany J.
    Algeciras-Schimnich, Alicia
    Singh, Ravinder J.
    Grebe, Stefan K.
    JOURNAL OF PROTEOME RESEARCH, 2023, 22 (04) : 1322 - 1330
  • [43] Developing a reference measurement procedure for free glycerol in human serum by two-step gas chromatography-isotope dilution mass spectrometry
    Chen, Yizhao
    Teo, Hui Ling
    Liu, Qinde
    Lee, Tong Kooi
    CLINICAL BIOCHEMISTRY, 2015, 48 (13-14) : 897 - 903
  • [44] Quantitation of plasma metanephrines using isotope dilution liquid chromatography tandem mass spectrometry (ID-LC/MS/MS): a candidate reference measurement procedure and its application to evaluating routine ID-LC/MS/MS methods
    Liu, Zhenni
    Liu, Qingxiang
    Deng, Yuhang
    Zhao, Haijian
    Zeng, Jie
    Zhang, Tianjiao
    Zhang, Jiangtao
    Wang, Jing
    Zhou, Weiyan
    Zhang, Chuanbao
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (30) : 7509 - 7520
  • [45] Quantitation of plasma metanephrines using isotope dilution liquid chromatography tandem mass spectrometry (ID-LC/MS/MS): a candidate reference measurement procedure and its application to evaluating routine ID-LC/MS/MS methods
    Zhenni Liu
    Qingxiang Liu
    Yuhang Deng
    Haijian Zhao
    Jie Zeng
    Tianjiao Zhang
    Jiangtao Zhang
    Jing Wang
    Weiyan Zhou
    Chuanbao Zhang
    Analytical and Bioanalytical Chemistry, 2021, 413 : 7509 - 7520
  • [46] Measurement of Cortisol in Human Serum by Isotope Dilution Liquid Chromatography/Mass Spectrometry and a Comparison through a Proficiency Testing
    Lee, Hwashim
    Shin, Hyesun
    Park, Sangryoul
    Park, Chang Joon
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2010, 31 (05) : 1149 - 1154
  • [47] Quantification of monofluoroacetate and monochloroacetate in human urine by isotope dilution liquid chromatography tandem mass spectrometry
    Hamelin, Elizabeth I.
    Mawhinney, Douglas B.
    Parry, Ritchard
    Kobelski, Robert J.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (15-16): : 1045 - 1050
  • [48] Quantitation of navtemadlin in human plasma and brain tissue by liquid chromatography-tandem mass spectrometry
    Kagan, Amanda B.
    Anders, Nicole M.
    Hemingway, Avelina
    Lee, Eudocia Q.
    Kelly, Kevin R.
    Lee, Hans C.
    Xu-Welliver, Meng
    Piekarz, Richard
    Rudek, Michelle A.
    BIOMEDICAL CHROMATOGRAPHY, 2022, 36 (11)
  • [49] Quantification of Human Plasma-Busulfan Concentration by Liquid Chromatography-Tandem Mass Spectrometry
    Moon, Soo Young
    Lim, Min Kyoo
    Hong, Susie
    Jeon, Yongbum
    Han, Minje
    Song, Sang Hoon
    Lim, Kyoung Soo
    Yu, Kyung-Sang
    Jang, In-Jin
    Lee, Ji Won
    Kang, Hyoung Jin
    Song, Junghan
    ANNALS OF LABORATORY MEDICINE, 2014, 34 (01) : 7 - 14
  • [50] Enantioselective assay of nimodipine in human plasma using liquid chromatography-tandem mass spectrometry
    Isse, Fadumo Ahmed
    Le, Tyson
    Mahmoud, Sherif Hanafy
    BIOMEDICAL CHROMATOGRAPHY, 2021, 35 (02)