An isotope dilution liquid chromatography-tandem mass spectrometry candidate reference measurement procedure for aldosterone measurement in human plasma

被引:6
|
作者
Zhang, Qiaoxuan [1 ,2 ]
Han, Liqiao [1 ]
Zheng, Songbai [3 ]
Ouyang, Fen [1 ]
Wu, Xiaobin [1 ]
Yan, Jun [1 ]
Zhan, Min [1 ]
Ke, Peifeng [1 ]
Zhuang, Junhua [1 ]
Huang, Xianzhang [1 ]
机构
[1] Guangzhou Univ Chinese Med, Affiliated Hosp 2, Dept Lab Med, Guangzhou 510120, Guangdong, Peoples R China
[2] Guangzhou Univ Chinese Med, Clin Med Coll 2, Guangzhou 510120, Guangdong, Peoples R China
[3] Fujian Huayin Med Lab Ctr, Xiamen 361101, Fujian, Peoples R China
关键词
Aldosterone; Reference measurement procedure; Tandem mass spectrometry; Clinical laboratory measurements;
D O I
10.1007/s00216-021-03405-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Accurate quantitation of aldosterone is clinically important in standardized testing for primary aldosteronism. The results are often variable when performed by clinical immunoassays. To standardize and ensure the accuracy of clinical systems, reference measurement procedures (RMPs) with higher metrological order are required. A simple and reliable isotope dilution LC-IDMS/MS-based measurement procedure for human plasma aldosterone has been developed. This method involved plasma spiked with a deuterium-labelled internal standard, equilibrated for 0.5 h, and extracted by liquid-liquid extraction (LLE) without derivatization. Aldosterone and its structural analogues were baseline separated with a C18-packed UHPLC column with gradient elution within 7 min. The signal intensity variability and measurement imprecision were reduced by bracketing calibration during plasma aldosterone value assignment. The limit of detection (LoD) was 19.4 pmol/L with a signal-to-noise ratio (S/N) > 3. The lowest limit of quantification (LLoQ) was 27.7 pmol/L (S/N > 10 and CV < 10.0%). LLE was performed with 1 mL of n-hexane/ethyl acetate (3:2, v/v), and the extraction recovery was determined to be 92.15 +/- 3.54%. The imprecisions were <= 3.18% for samples at 124.8, 867.0, and 2628.5 pmol/L. The recoveries were 98.11-101.61%. The relative bias between this candidate RMP and the established RMP was 2.76-1.89%. The linearity response ranged from 27.7 to 2774.4 pmol/L with R-2 = 0.999. The method performance met the requirements of RMPs (<= 5% total CV and <= 3% bias). Furthermore, the developed method was applied to evaluate immunoassays through 41 patient sample comparisons. The calibration and measurement capability (CMC) of this method were also evaluated by measuring these samples. The candidate RMP can serve as an accurate reference baseline for routine methods and can be used for value assignment for reference materials.
引用
收藏
页码:4471 / 4481
页数:11
相关论文
共 50 条
  • [31] Developing an ultra-performance liquid chromatography-tandem mass spectrometry for detecting aldosterone in human plasma
    Lin, Wenbin
    Yao, Zhenrong
    Li, Yuzhe
    Liao, Zhihao
    Xiao, Jiahao
    Chen, Yonghong
    Feng, Pinning
    Gan, Wenjia
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2021, 35 (11)
  • [32] Measurement of human serum unconjugated estriol without derivatization using liquid chromatography-tandem mass spectrometry candidate reference method and compared with two immunoassays
    Xianzhang Huang
    Qiaoxuan Zhang
    Songbai Zheng
    Jianbing Wang
    Liqiao Han
    Haibiao Lin
    Peifeng Ke
    Junhua Zhuang
    Zhimin (Tim) Cao
    Analytical and Bioanalytical Chemistry, 2018, 410 : 6257 - 6267
  • [33] Measurement of human serum unconjugated estriol without derivatization using liquid chromatography-tandem mass spectrometry candidate reference method and compared with two immunoassays
    Huang, Xianzhang
    Zhang, Qiaoxuan
    Zheng, Songbai
    Wang, Jianbing
    Han, Liqiao
    Lin, Haibiao
    Ke, Peifeng
    Zhuang, Junhua
    Cao, Zhimin
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2018, 410 (24) : 6257 - 6267
  • [34] Quantitation of terameprocol in human plasma by liquid chromatography-tandem mass spectrometry
    Anders, Nicole M.
    Romo, Carlos G.
    Hemingway, Avelina
    Ahluwalia, Manmeet S.
    Rudek, Michelle A.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2022, 209
  • [35] Measurement of estradiol, estrone, and testosterone in postmenopausal human serum by isotope dilution liquid chromatography tandem mass spectrometry without derivatization
    Wooding, Kerry M.
    Hankin, Joseph A.
    Johnson, Chris A.
    Chosich, Justin D.
    Baek, Sung W.
    Bradford, Andrew P.
    Murphy, Robert C.
    Santoro, Nanette
    STEROIDS, 2015, 96 : 89 - 94
  • [36] Quantification of micafungin in human plasma by liquid chromatography-tandem mass spectrometry
    Cangemi, Giuliana
    Barco, Sebastiano
    Bandettini, Roberto
    Castagnola, Elio
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2014, 406 (06) : 1795 - 1798
  • [37] Quantification of micafungin in human plasma by liquid chromatography-tandem mass spectrometry
    Giuliana Cangemi
    Sebastiano Barco
    Roberto Bandettini
    Elio Castagnola
    Analytical and Bioanalytical Chemistry, 2014, 406 : 1795 - 1798
  • [38] Chinese normotensive and essential hypertensive reference intervals for plasma aldosterone and renin activity by liquid chromatography-tandem mass spectrometry
    Cheng, Jenny Yeuk-Ki
    Wong, Felix Chi-Kin
    Chow, Edith Wing-Kar
    Lau, Wendy Wan-Hang
    Cheung, Kitty Kit-Ting
    Cheng, Timothy Hua-Tse
    Tsui, Teresa Kam-Chi
    Chan, Alan Shek-Lun
    Lo, Clara Wai-Shan
    Ho, Chung-Shun
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2022, 60 (10) : 1640 - 1647
  • [39] Simple and accurate candidate reference measurement procedure for total testosterone in human serum by one-step liquid-liquid extraction coupled with isotope dilution mass spectrometry
    Chen, Yizhao
    Teo, Hui Ling
    Liu, Hong
    Loh, Tze Ping
    Liu, Qinde
    Teo, Tang Lin
    Lee, Tong Kooi
    Sethi, Sunil Kumar
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2019, 411 (28) : 7519 - 7528
  • [40] Simple and accurate candidate reference measurement procedure for total testosterone in human serum by one-step liquid-liquid extraction coupled with isotope dilution mass spectrometry
    Yizhao Chen
    Hui Ling Teo
    Hong Liu
    Tze Ping Loh
    Qinde Liu
    Tang Lin Teo
    Tong Kooi Lee
    Sunil Kumar Sethi
    Analytical and Bioanalytical Chemistry, 2019, 411 : 7519 - 7528