Multi-institutional Feasibility Study of a Fast Patient Localization Method in Total Marrow Irradiation With Helical Tomotherapy: A Global Health Initiative by the International Consortium of Total Marrow Irradiation

被引:12
作者
Takahashi, Yutaka [1 ]
Vagge, Stefano [8 ,9 ]
Agostinelli, Stefano [8 ,9 ]
Han, Eunyoung [10 ]
Matulewicz, Lukasz [11 ,12 ]
Schubert, Kai [13 ]
Chityala, Ravishankar [2 ,3 ]
Ratanatharathorn, Vaneerat [10 ]
Tournel, Koen [14 ]
Penagaricano, Jose A. [10 ]
Florian, Sterzing [13 ]
Mahe, Marc-Andre [15 ]
Verneris, Michael R. [4 ,5 ,6 ]
Weisdorf, Daniel J. [7 ]
Corvo, Renzo [8 ,9 ]
Dusenbery, Kathryn E. [2 ]
Storme, Guy [14 ]
Hui, Susanta K. [1 ,2 ]
机构
[1] Univ Minnesota, Masonic Canc Ctr, Minneapolis, MN 55455 USA
[2] Univ Minnesota, Dept Therapeut Radiol, Minneapolis, MN 55455 USA
[3] Univ Minnesota, Minnesota Super Comp Inst, Minneapolis, MN 55455 USA
[4] Univ Minnesota, Div Hematol, Dept Pediat, Minneapolis, MN 55455 USA
[5] Univ Minnesota, Div Oncol, Dept Pediat, Minneapolis, MN 55455 USA
[6] Univ Minnesota, Div Bone Marrow Transplantat, Dept Pediat, Minneapolis, MN 55455 USA
[7] Univ Minnesota, Dept Med, Minneapolis, MN 55455 USA
[8] Natl Inst Canc Res, Dept Radiat Oncol, Genoa, Italy
[9] Univ Genoa, Genoa, Italy
[10] Univ Arkansas Med Sci, Dept Radiat Oncol, Little Rock, AR 72205 USA
[11] Maria Sklodowska Curie Mem Canc Ctr, Dept Radiat Oncol, Gliwice, Poland
[12] Inst Oncol, Gliwice, Poland
[13] Heidelberg Univ, Dept Radiat Oncol, Heidelberg, Germany
[14] Univ Ziekenhuis Brussel, Dept Radiotherapy, Brussels, Belgium
[15] Integrated Ctr Oncol Rene Gauducheau, Dept Radiat Oncol, St Herblain, France
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2015年 / 91卷 / 01期
关键词
TOTAL-BODY IRRADIATION; GUIDED TOTAL-MARROW; HEMATOPOIETIC-CELL TRANSPLANTATION; BONE-MARROW; MULTIPLE-MYELOMA; RANDOMIZED-TRIAL; LEUKEMIA; EXPERIENCE; REGIMENS; PHASE;
D O I
10.1016/j.ijrobp.2014.09.014
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To develop, characterize, and implement a fast patient localization method for total marrow irradiation. Methods and Materials: Topographic images were acquired using megavoltage computed tomography (MVCT) detector data by delivering static orthogonal beams while the couch traversed through the gantry. Geometric and detector response corrections were performed to generate a megavoltage topogram (MVtopo). We also generated kilovoltage topograms (kVtopo) from the projection data of 3-dimensional CT images to reproduce the same geometry as helical tomotherapy. The MVtopo imaging dose and the optimal image acquisition parameters were investigated. A multi-institutional phantom study was performed to verify the image registration uncertainty. Forty-five MVtopo images were acquired and analyzed with in-house image registration software. Results: The smallest jaw size (front and backup jaws of 0) provided the best image contrast and longitudinal resolution. Couch velocity did not affect the image quality or geometric accuracy. The MVtopo dose was less than the MVCT dose. The image registration uncertainty from the multi-institutional study was within 2.8 mm. In patient localization, the differences in calculated couch shift between the registration with MVtopo-kVtopo and MVCT-kVCT images in lateral, cranialecaudal, and vertical directions were 2.2 +/- 1.7 mm, 2.6 +/- 1.4 mm, and 2.7 +/- 1.1 mm, respectively. The imaging time in MVtopo acquisition at the couch speed of 3 cm/s was <1 minute, compared with >= 15 minutes in MVCT for all patients. Conclusion: Whole-body MVtopo imaging could be an effective alternative to time-consuming MVCT for total marrow irradiation patient localization. (C) 2015 Elsevier Inc.
引用
收藏
页码:30 / 38
页数:9
相关论文
共 26 条
  • [1] Relapse alter allogeneic bone marrow transplantation for refractory anemia is increased by shielding lungs and liver during total body irradiation
    Anderson, JE
    Appelbaum, FR
    Schoch, G
    Barnett, T
    Chauncey, TR
    Flowers, MED
    Storb, R
    [J]. BIOLOGY OF BLOOD AND MARROW TRANSPLANTATION, 2001, 7 (03) : 163 - 170
  • [2] Imaging system QA of a medical accelerator, Novalis Tx, for IGRT per TG 142: our 1 year experience
    Chang, Zheng
    Bowsher, James
    Cai, Jing
    Yoo, Sua
    Wang, Zhiheng
    Adamson, Justus
    Ren, Lei
    Yin, Fang-Fang
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2012, 13 (04): : 113 - 140
  • [3] Long-term follow-up of a randomized trial of two irradiation regimens for patients receiving allogeneic marrow transplants during first remission of acute myeloid leukemia
    Clift, RA
    Buckner, CD
    Appelbaum, FR
    Sullivan, KM
    Storb, R
    Thomas, ED
    [J]. BLOOD, 1998, 92 (04) : 1455 - 1456
  • [4] CLIFT RA, 1991, BLOOD, V77, P1660
  • [5] Helical tomotherapy targeting total bone marrow after total body irradiation for patients with relapsed acute leukemia undergoing an allogeneic stem cell transplant
    Corvo, Renzo
    Zeverino, Michele
    Vagge, Stefano
    Agostinelli, Stefano
    Barra, Salvina
    Taccini, Gianni
    Van Lint, Maria Teresa
    Frassoni, Francesco
    Bacigalupo, Andrea
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 98 (03) : 382 - 386
  • [6] A new conditioning regimen involving total marrow irradiation, busulfan and cyclophosphamide followed by autologous PBSCT in patients with advanced multiple myeloma
    Einsele, H
    Bamberg, M
    Budach, W
    Schmidberger, H
    Hess, CF
    Wörmann, B
    Meisner, C
    Straka, C
    Hebart, H
    Trümper, L
    Kröger, N
    Zander, AR
    Hegewisch-Becker, S
    Hossfeld, DK
    Schmidt, H
    Müller, P
    Schlimok, G
    Hertenstein, B
    Peest, D
    Metzner, B
    Frickhofen, N
    Kanz, L
    Bensinger, WI
    [J]. BONE MARROW TRANSPLANTATION, 2003, 32 (06) : 593 - 599
  • [7] Autologous stem cell transplantation for high-risk Ewing's sarcoma and other pediatric solid tumors
    Fraser, CJ
    Weigel, BJ
    Perentesis, JP
    Dusenbery, KE
    DeFor, TE
    Baker, KS
    Verneris, MR
    [J]. BONE MARROW TRANSPLANTATION, 2006, 37 (02) : 175 - 181
  • [8] Total body irradiation - Report on a meeting organized by the BIR Oncology Committee, held at The Royal Institute of British Architects, London, 28 November 1996
    Gilson, D
    Taylor, RE
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1997, 70 (840) : 1201 - 1203
  • [9] Herman M G, 2000, J Appl Clin Med Phys, V1, P38, DOI 10.1120/1.308249
  • [10] Hui SK, 2012, STRAHLENTHER ONKOL, V188, P346, DOI 10.1007/s00066-011-0066-z