Coma-corrected rapid single-particle cryo-EM data collection on the CRYO ARM 300

被引:18
|
作者
Efremov, Rouslan G. [1 ,2 ]
Stroobants, Annelore [1 ,2 ]
机构
[1] Vlaams Inst Biotechnol, Ctr Struct Biol, Pl Laan 2, B-1050 Brussels, Belgium
[2] Vrije Univ Brussel, Struct Biol Brussels, Pl Laan 2, B-1050 Brussels, Belgium
来源
ACTA CRYSTALLOGRAPHICA SECTION D-STRUCTURAL BIOLOGY | 2021年 / 77卷
关键词
single-particle cryo-EM; high throughput; high-resolution 3D reconstruction; ELECTRON; DEFOCUS;
D O I
10.1107/S2059798321002151
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Single-particle cryogenic electron microscopy has recently become a major method for determining the structures of proteins and protein complexes. This has markedly increased the demand for throughput of high-resolution electron microscopes, which are required to produce high-resolution images at high rates. An increase in data-collection throughput can be achieved by using large beam-image shifts combined with off-axis coma correction, enabling the acquisition of multiple images from a large area of the EM grid without moving the microscope stage. Here, the optical properties of the JEOL CRYO ARM 300 electron microscope equipped with a K3 camera were characterized under off-axis illumination conditions. It is shown that efficient coma correction can be achieved for beam-image shifts with an amplitude of at least 10 mu m, enabling a routine throughput for data collection of between 6000 and 9000 images per day. Use of the benchmark for the rapid data-collection procedure (with beam-image shifts of up to 7 mu m) on apoferritin resulted in a reconstruction at a resolution of 1.7 angstrom. This demonstrates that the rapid automated acquisition of high-resolution micrographs is possible using a CRYO ARM 300.
引用
收藏
页码:555 / 564
页数:10
相关论文
共 32 条
  • [1] Assessing the JEOL CRYO ARM 300 for high-throughput automated single-particle cryo-EM in a multiuser environment
    Fislage, Marcus
    Shkumatov, Alexander, V
    Stroobants, Annelore
    Efremov, Rouslan G.
    IUCRJ, 2020, 7 : 707 - 718
  • [2] A potential difference for single-particle cryo-EM
    Rosenthal, Peter B.
    IUCRJ, 2019, 6 : 988 - 989
  • [3] Single-particle cryo-EM: beyond the resolution
    Jean-Paul Armache
    Yifan Cheng
    NationalScienceReview, 2019, 6 (05) : 864 - 866
  • [4] goCTF: Geometrically optimized CTF determination for single-particle cryo-EM
    Su, Min
    JOURNAL OF STRUCTURAL BIOLOGY, 2019, 205 (01) : 22 - 29
  • [5] Joint Angular Refinement and Reconstruction for Single-Particle Cryo-EM
    Zehni, Mona
    Donati, Laurene
    Soubies, Emmanuel
    Zhao, Zhizhen
    Unser, Michael
    IEEE TRANSACTIONS ON IMAGE PROCESSING, 2020, 29 : 6151 - 6163
  • [6] Host Receptor Pili for Cryo-EM Single-Particle Reconstruction
    Meng, Ran
    BIO-PROTOCOL, 2024, 14 (20):
  • [7] Single-particle cryo-EM data acquisition by using direct electron detection camera
    Wu, Shenping
    Armache, Jean-Paul
    Cheng, Yifan
    MICROSCOPY, 2016, 65 (01) : 35 - 41
  • [8] A new cryo-EM system for single particle analysis
    Hamaguchi, Tasuku
    Maki-Yonekura, Saori
    Naitow, Hisashi
    Matsuura, Yoshinori
    Ishikawa, Tetsuya
    Yonekura, Koji
    JOURNAL OF STRUCTURAL BIOLOGY, 2019, 207 (01) : 40 - 48
  • [9] SIMPLE 3.0. Stream single-particle cryo-EM analysis in real time
    Caesar, Joseph
    Reboul, Cyril F.
    Machello, Chiara
    Kiesewetter, Simon
    Tang, Molly L.
    Deme, Justin C.
    Johnson, Steven
    Elmlund, Dominika
    Lea, Susan M.
    Elmlund, Hans
    JOURNAL OF STRUCTURAL BIOLOGY-X, 2020, 4
  • [10] Non-uniform Fourier transform based image classification in single-particle Cryo-EM
    Bai, Zijian
    Huang, Jian
    JOURNAL OF STRUCTURAL BIOLOGY-X, 2025, 11