An ultralow stress Ta4B absorber for x-ray masks

被引:10
作者
Shoki, T
Ohkubo, R
Sakurai, T
Kawahara, T
Annaka, N
Yabe, H
Aya, S
机构
[1] HOYA Corp, R&D Ctr, Tokyo 196, Japan
[2] HOYA Corp, Electroopt Co, Yamanashi 40916, Japan
[3] Mitsubishi Elect Co, Adv Technol R&D Ctr, Amagasaki, Hyogo 661, Japan
来源
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS | 1997年 / 36卷 / 12B期
关键词
X-ray mask; absorber; Ta4B; stress; stress uniformity; annealing; etching;
D O I
10.1143/JJAP.36.7586
中图分类号
O59 [应用物理学];
学科分类号
摘要
The stress controllability, stress uniformity, stress stability and dry etching characteristics of Ta4B films deposited by an in-line type sputtering system were investigated in detail. Low average stress Ta4B films within +/-10 MPa have been fabricated on polished SIC films that demonstrate excellent reproducibility by step annealing. Stress uniformity of the film showed an approximate range of 7 MPa on a Si wafer in a 30 mm square area when the deposition conditions were modified. The Ta4B him demonstrated long-term stress stability and excellent resistance to the acid and water used in the cleaning process. The Ta4B film also ensures fine pattern formations below 0.2 mu m.
引用
收藏
页码:7586 / 7590
页数:5
相关论文
共 50 条
  • [31] Electron beam writing techniques for fabricating highly accurate X-ray masks
    Kise, K
    Aya, S
    Yabe, H
    Marumoto, K
    Hifumi, T
    Matsui, Y
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 1995, 34 (12B): : 6738 - 6742
  • [32] Advanced refractory-metal and process technology for the fabrication of x-ray masks
    Brooks, CJ
    Racette, KC
    Lercel, MJ
    Powers, LA
    Benoit, DE
    EMERGING LITHOGRAPHIC TECHNOLOGIES III, PTS 1 AND 2, 1999, 3676 : 14 - 23
  • [33] Portable X-ray apparatus for stress measurements
    Monin, VI
    Assis, JT
    Pereira, FR
    Gurova, T
    Teodósio, J
    THERMEC'2003, PTS 1-5, 2003, 426-4 : 4531 - 4534
  • [34] Stress strain tensors with their application to X-ray stress measurement
    Kurita, Masanori
    Zairyo/Journal of the Society of Materials Science, Japan, 2015, 64 (12) : 1003 - 1009
  • [35] Overlay and critical dimension control in 100-nm ULSI processes using TaBN x-ray masks and XRA x-ray stepper
    Fujii, K
    Tanaka, Y
    Iwamoto, T
    Tsuboi, S
    Sumitani, H
    Taguchi, T
    Suzuki, K
    Matsui, Y
    EMERGING LITHOGRAPHIC TECHNOLOGIES V, 2001, 4343 : 155 - 163
  • [36] Planar Technology for NDT-Ge X-Ray Microcalorimeters: Absorber Fabrication
    Lo Cicero, U.
    Arnone, C.
    Barbera, M.
    Collura, A.
    Lullo, G.
    Perinati, E.
    Varisco, S.
    LOW TEMPERATURE DETECTORS LTD 13, 2009, 1185 : 112 - +
  • [37] A tunable wedge-shaped absorber for hard X-ray synchrotron applications
    Krywka, C.
    Brix, M.
    Mueller, M.
    JOURNAL OF SYNCHROTRON RADIATION, 2014, 21 : 811 - 814
  • [38] Self-supporting tantalum masks for deep X-ray lithography with synchrotron radiation
    Litvina, SV
    Kanaev, VG
    Larionova, EG
    Glazunova, NV
    Gromova, LP
    Yurchenko, VI
    Timchenko, NA
    Mezentseva, LA
    Nazmov, VP
    Pindyurin, VF
    EMERGING LITHOGRAPHIC TECHNOLOGIES III, PTS 1 AND 2, 1999, 3676 : 426 - 428
  • [39] Monte Carlo study of backscattered electron signals from microstructures of x-ray masks
    Yasuda, M
    Fujii, K
    Kawata, H
    Murata, K
    OPTIK, 2001, 112 (08): : 321 - 328
  • [40] X-ray stress measurement of carbide in tool steel
    Gotoh, M
    Hirose, H
    Sasaki, T
    RESIDUAL STRESSES VII, PROCEEDINGS, 2005, 490-491 : 281 - 286