LigaSure versus clamp-and-tie in thyroidectomy: a single-center experience

被引:18
作者
Cakabay, Bahri [1 ]
Sevinc, Mert Mahsuni [1 ]
Gomceli, Ismail [1 ]
Yenidogan, Erdinc [1 ]
Ulku, Abdullah [1 ]
Koc, Semsettin [1 ]
机构
[1] Diyarbakir Educ & Res Hosp, Dept Surg, Diyarbakir, Turkey
关键词
clamp-and-tie; LigaSure; suture ligation; thyroidectomy; ULTRASONICALLY ACTIVATED SHEARS; RANDOMIZED CLINICAL-TRIAL; VESSEL SEALING SYSTEM; HARMONIC SCALPEL; SURGERY; DIATHERMY; DISSECTOR;
D O I
10.1007/s12325-009-0078-6
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
LigaSure (ValleyLab, CO, USA) is a bipolar diathermy system that seals vessels with reduced thermal spread. The device has been used successfully in abdominal surgery and has been introduced as a new method for hemostasis during thyroidectomy. This study compares the efficacy and advantages of LigaSure, when used for thyroidectomy in benign nodular thyroid disease, with the conventional clamp-and-tie technique. Between December 2003 and December 2008, 410 patients underwent thyroid surgery (333 with the conventional clamp-and-tie technique and 77 with LigaSure). Nine patients did not sign the ethical approval document and so were excluded from the study; the results of 68 LigaSure patients were evaluated. The main outcomes measured were age, sex, operating time, postoperative hypocalcemia, recurrent laryngeal nerve palsy, and drain use. Statistical analysis consisted of the chi-squared test and Student's t-test. The mean operating time was significantly shorter in the LigaSure group by 24.1 +/- 1.7 minutes for a total thyroidectomy (P < 0.0001) and 7.6 +/- 0.1 minutes for one side total plus other side sub- total thyroidectomy (P < 0.0001). Bleeding during surgery was significantly lower in the LigaSure group (P < 0.0001). There were no significant differences between the study groups in terms of postoperative hypoparathyroidism, recurrent laryngeal nerve palsy, and postthyroidectomy hemorrhage. The LigaSure vessel sealer is a safe, effective alternative for thyroid surgery that reduces the overall operating time. However, its higher cost is a significant handicap for its use in surgery in developing countries.
引用
收藏
页码:1035 / 1041
页数:7
相关论文
共 19 条
[1]  
Defechereux T, 2003, ACTA CHIR BELG, V103, P274
[2]   The use of a vessel sealing system in thyroid surgery [J].
Dilek, ON ;
Yilmaz, S ;
Degirmenci, B ;
Sahin, DA ;
Akbulut, G ;
Dilek, FH .
ACTA CHIRURGICA BELGICA, 2005, 105 (04) :369-372
[3]   Randomized clinical trial of LigasureTM versus conventional diathermy for day-case haemorrhoidectomy [J].
Jayne, DG ;
Botterill, I ;
Ambrose, NS ;
Brennan, TG ;
Guillou, PJ ;
O'Riordain, DS .
BRITISH JOURNAL OF SURGERY, 2002, 89 (04) :428-432
[4]   Use of Ligasure in thyroidectomy procedures: Results of a prospective comparative study [J].
Kirdak, T ;
Korun, N ;
Ozguc, H .
WORLD JOURNAL OF SURGERY, 2005, 29 (06) :771-774
[5]   Use of a diathermy system in thyroid surgery [J].
Kiriakopoulos, A ;
Dimitrios, T ;
Dimitrios, L .
ARCHIVES OF SURGERY, 2004, 139 (09) :997-1000
[6]   A double-blind, randomized trial comparing Ligasure™ and Harmonic Scalpel™ hemorrhoidectomy [J].
Kwok, SY ;
Chung, CC ;
Tsui, KK ;
Li, MKW .
DISEASES OF THE COLON & RECTUM, 2005, 48 (02) :344-348
[7]   The use of Ligasure Vessel Sealing System in thyroid surgery [J].
Lachanas, VA ;
Prokopakis, EP ;
Mpenakis, AA ;
Karatzanis, AD ;
Velegrakis, GA .
OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2005, 132 (03) :487-489
[8]   Randomized clinical trial of Ligasure™ versus conventional surgery for extended gastric cancer resection [J].
Lee, WJ ;
Chen, TC ;
Lai, IR ;
Wang, W ;
Huang, MT .
BRITISH JOURNAL OF SURGERY, 2003, 90 (12) :1493-1496
[9]   Randomized trial of suture versus electrosurgical bipolar vessel sealing in vaginal hysterectomy [J].
Levy, B ;
Emery, L .
OBSTETRICS AND GYNECOLOGY, 2003, 102 (01) :147-151
[10]   Evaluation of the Ultracision® ultrasonic dissector in thyroid surgery.: A prospective randomized study [J].
Meurisse, M ;
Defechereux, T ;
Maweja, S ;
Degauque, C ;
Vandelaer, M ;
Hamoir, E .
ANNALES DE CHIRURGIE, 2000, 125 (05) :468-472