Evaluation of chloride contamination in concrete using electromagnetic non-destructive testing methods

被引:30
作者
Derobert, Xavier [1 ]
Lataste, J. F. [2 ]
Balayssac, J. -P. [3 ]
Laurens, S. [3 ]
机构
[1] LUNAM Univ, IFSTTAR, CS4, F-44344 Bouguenais, France
[2] Univ Bordeaux, I2M, F-33400 Talence, France
[3] INSA UPS Genie Civil, LMDC, 135 Ave Rangueil, F-31077 Toulouse 04, France
关键词
Radar; Resistivity; Capacitance; Humidity; Concrete; Chloride; Measurement uncertainty; GROUND-PENETRATING RADAR; ELECTRICAL-RESISTIVITY; NDT METHODS; MOISTURE; INGRESS; DURABILITY; CORROSION; ZONE; WAVE;
D O I
10.1016/j.ndteint.2017.03.006
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
We present the results of the sensitivity of some electromagnetic non-destructive testing (NDT) methods to chloride contamination. The NDT methods are resistivity, using a quadripole probe, capacitive technique, with few sets of electrodes, and radar technique, using different bistatic configurations. A laboratory study was carried out involving three different concretes with different water to cement ratios. The concretes were conditioned with different degrees of NaCl saturation by means of three solutions containing 0 g/L, 30 g/l or 120 g/l. The solution was homogenized in the concrete by using a specific procedure. Results show that the EM techniques are very sensitive to the chloride content and saturation rate and, on a second level, to the porosity. Multi-linear regression processing was performed to estimate the level of sensitivity of the NDT measurements to the three indicators. Values of ten ND observables are presented and discussed. At last, the uncertainties of the regression models are studied on a real structure in a tidal zone.
引用
收藏
页码:19 / 29
页数:11
相关论文
共 29 条
[1]   Chloride ion penetration in concrete: The reaction factor in the electrical resistivity model [J].
Andrade, Carmen ;
d'Andrea, Renata ;
Rebolledo, Nuria .
CEMENT & CONCRETE COMPOSITES, 2014, 47 :41-46
[2]   Description of the general outlines of the French project SENSO - Quality assessment and limits of different NDT methods [J].
Balayssac, J. -P. ;
Laurens, S. ;
Arliguie, G. ;
Breysse, D. ;
Garnier, V. ;
Derobert, X. ;
Piwakowski, B. .
CONSTRUCTION AND BUILDING MATERIALS, 2012, 35 :131-138
[3]  
Balayssac JP, 2010, 2 INT C MEDACHS 10 P
[4]   AgNO3 spray tests:: advantages, weaknesses, and various applications to quantify chloride ingress into concrete.: part 1:: Non-steady-state diffusion tests and exposure to natural conditions [J].
Baroghel-Bouny, Veronique ;
Belin, Patrick ;
Maultzsch, Matthias ;
Henry, Dominique .
MATERIALS AND STRUCTURES, 2007, 40 (08) :759-781
[5]   Temperature influence on electromagnetic measurements of concrete moisture [J].
Chataigner, Sylvain ;
Saussol, Jean-Luc ;
Derobert, Xavier ;
Villain, Geraldine ;
Aubagnac, Christophe .
EUROPEAN JOURNAL OF ENVIRONMENTAL AND CIVIL ENGINEERING, 2015, 19 (04) :482-495
[6]  
Derobert X, 2009, 7 INT S NDT CE P NAN
[7]  
Derobert X, 2008, 1 INT C MEDACHS 08 P
[8]   Use of capacitive and GPR techniques for the non-destructive evaluation of cover concrete [J].
Derobert, Xavier ;
Iaquinta, Jean ;
Klysz, Gilles ;
Balayssac, Jean-Paul .
NDT & E INTERNATIONAL, 2008, 41 (01) :44-52
[9]   Detection of chlorides and moisture in concrete structures with ground penetrating radar [J].
Hugenschmidt, Johannes ;
Loser, Roman .
MATERIALS AND STRUCTURES, 2008, 41 (04) :785-792
[10]   The resistivity of pore water solution - A decisive parameter of rebar corrosion and repair methods [J].
Hunkeler, F .
CONSTRUCTION AND BUILDING MATERIALS, 1996, 10 (05) :381-389