Determination of phytic acid and its degradation products by ion-pair chromatography (IPC) coupled to inductively coupled plasma-sector field-mass spectrometry (ICP-SF-MS)

被引:29
|
作者
Helfrich, A [1 ]
Bettmer, J [1 ]
机构
[1] Univ Mainz, Inst Inorgan Chem & Analyt Chem, D-55009 Mainz, Germany
关键词
D O I
10.1039/b406916a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We developed a method for the determination of phytic acid (IP6) and its degradation products (IP1-IP5) by ion-pair chromatography coupled to a double focussing inductively coupled plasma-sector field-mass spectrometer (ICP-SF-MS). For the detection of the phosphorus species a mass resolution (m/Deltam) of 4000 was needed in order to separate the P-31(+) signal from the interfering clusterions. The separation of the six phosphorus species was enabled by a gradient elution using tetrabutylammonium hydroxide (TBA) as ion-pair reagent. Calibration data were reported and a detection limit of 230 ng g(-1) for IP6 could be obtained. The method was. rstly proved for a hydrolyzate of commercially available phytic acid and then applied to various real samples like nuts, cereals, legumes, beer etc. In all samples different pattern of inositol phosphates could be detected. The compositional comparison of inositol phosphates in a malt and a beer sample showed that during the brewing process IP6 is completely degraded to IP2 and IP3.
引用
收藏
页码:1330 / 1334
页数:5
相关论文
共 50 条
  • [21] Simultaneous determination of chromium speciation in cosmetics using reversed-phase ion-pair chromatography-inductively coupled plasma mass spectrometry
    Pang Yanhua
    Liu Mingyang
    Liu Shuyan
    Dong Zhenlin
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2011, 29 (10) : 1027 - 1030
  • [22] Determination of iodine species in seaweed and seawater samples using ion-pair reversed phase high performance liquid chromatography coupled with inductively coupled plasma mass spectrometry
    Han, Xu
    Cao, Lianghui
    Cheng, Heyong
    Liu, Jinhua
    Xu, Zigang
    ANALYTICAL METHODS, 2012, 4 (10) : 3471 - 3477
  • [23] Determination of interactions between antibody biotherapeutics and copper by size exclusion chromatography (SEC) coupled with inductively coupled plasma mass spectrometry (ICP/MS)
    Luo, Yanxin
    Ronk, Michael
    Joubert, Marisa K.
    Semin, David
    Nashed-Samuel, Yasser
    ANALYTICA CHIMICA ACTA, 2019, 1079 : 252 - 259
  • [24] Determination of 239Pu in urine by sector field inductively coupled plasma mass spectrometry (SF-ICP-MS) using an automated offline sample preparation technique
    Xiao, Ge
    Jones, Robert L.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2021, 328 (01) : 277 - 287
  • [25] Determination of 239Pu in urine by sector field inductively coupled plasma mass spectrometry (SF-ICP-MS) using an automated offline sample preparation technique
    Ge Xiao
    Robert L. Jones
    Journal of Radioanalytical and Nuclear Chemistry, 2021, 328 : 277 - 287
  • [26] Determination of trace elements in human milk by inductively coupled plasma sector field mass spectrometry (ICP-SFMS)
    Prohaska, T
    Köllensperger, G
    Krachler, M
    De Winne, K
    Stingeder, G
    Moens, L
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2000, 15 (04) : 335 - 340
  • [27] Cadmium, chromium, lead, manganese and nickel concentrations in blood of women in non-polluted areas in Japan, as determined by inductively coupled plasma-sector field-mass spectrometry
    Masayuki Ikeda
    Fumiko Ohashi
    Yoshinari Fukui
    Sonoko Sakuragi
    Jiro Moriguchi
    International Archives of Occupational and Environmental Health, 2011, 84 : 139 - 150
  • [28] Speciation analysis of urine iodine by ion-pair reversed-phase liquid chromatography and inductively coupled plasma mass spectrometry
    Han, Chao
    Sun, Jiannan
    Cheng, Heyong
    Liu, Jinhua
    Xu, Zigang
    ANALYTICAL METHODS, 2014, 6 (14) : 5369 - 5375
  • [29] Cadmium, chromium, lead, manganese and nickel concentrations in blood of women in non-polluted areas in Japan, as determined by inductively coupled plasma-sector field-mass spectrometry
    Ikeda, Masayuki
    Ohashi, Fumiko
    Fukui, Yoshinari
    Sakuragi, Sonoko
    Moriguchi, Jiro
    INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, 2011, 84 (02) : 139 - 150
  • [30] Reversed-phase ion-pair chromatography with inductively coupled plasma-mass spectrometry detection for the determination of organo-tin compounds in waters
    Fairman, B
    Catterick, T
    Wheals, B
    Polinina, E
    JOURNAL OF CHROMATOGRAPHY A, 1997, 758 (01) : 85 - 92