摘要
Indoor air quality (IAQ) is affected by indoor pollution sources that release gases or particles into the air and depending on ventilation conditions, outdoor ambient air quality can also be contributing factor. Inadequate ventilation by limiting inflow-outflow of pollutants, proximity to field or busy road can increase indoor pollutant levels. For this study, two offices, one with natural ventilation and other with central AC system, within residential campus of IIT Kanpur were selected. Air quality in offices with varying ventilation conditions was monitored simultaneously indoor and outdoor. The aim was to compare the data for the two locations and elicit influence of ventilation conditions on indoor pollutant levels. Size segregated mass concentration of ambient aerosols and particle number concentration (PNC) were determined for indoor using cascade impactor, MOUDI and OPC, respectively. Outdoor coarse particle concentration (PM10) was determined using HVS sampler. The PM concentration was found to be highest in naturally ventilated office. As per the recently released ISHRAE standards for indoor environment (ISHRAE Standard-10001:2016), minimum acceptable limits for Class C are PM10 < 100 mu g/m(3) and PM2.5 < 25 mu g/m(3). Levels of particles recorded in these office spaces were 4-6 times higher than ISHRAE acceptable limits for PM2.5 and PM10, respectively. Particle number concentration (PNC) was also higher in naturally ventilated office space as concentration was more than 400,000 particles/cm(3) (<1 mu m) as compared to airconditioned office space (160,000 particles/cm(3)). The I/O ratio for PM10 was found to be 0.64 and 2.93 for Office 1 and Office 2, respectively.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 50 条
[31]   Indoor air quality differences between urban and rural preschools in Korea [J].
Yoon, Chungsik ;
Lee, Kiyoung ;
Park, Donguk .
ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2011, 18 (03) :333-345
[32]   Indoor air quality modeling for PM10, PM2.5, and PM1.0 in naturally ventilated classrooms of an urban Indian school building [J].
Goyal, Radha ;
Khare, Mukesh .
ENVIRONMENTAL MONITORING AND ASSESSMENT, 2011, 176 (1-4) :501-516
[33]   How teacher behaviors and perceptions, air change rates, and portable air purifiers affect indoor air quality in naturally ventilated schools [J].
Xia, Tian ;
Raneses, Julia ;
Schmiesing, Brixon ;
Garcia, Raquel ;
Walding, Alison ;
Demajo, Richardo ;
Schulz, Amy ;
Batterman, Stuart A. .
FRONTIERS IN PUBLIC HEALTH, 2024, 12
[34]   INDOOR AIR QUALITY ASSESSMENT IN SPACES DESIGNED FOR OFFICE ACTIVITIES: PAHs AND PHENOLS [J].
Bucur, E. ;
Vasile, A. ;
Petrescu, M. ;
Danet, A. .
JOURNAL OF ENVIRONMENTAL PROTECTION AND ECOLOGY, 2016, 17 (01) :9-17
[35]   KEY FACTORS DETERMINING INDOOR AIR PM10 CONCENTRATIONS IN NATURALLY VENTILATED PRIMARY SCHOOLS IN BELGRADE, SERBIA [J].
Matic, Branislava ;
Rakic, Uros ;
Jovanovic, Verica ;
Dejanovic, Snezana ;
Djonovic, Nela .
ZDRAVSTVENO VARSTVO, 2017, 56 (04) :227-235
[36]   A seasonal assessment of indoor air quality and thermal performance in naturally ventilated airtight energy-efficient dwellings [J].
Alhindawi, Ibrahim ;
Mcgrath, James A. ;
Sood, Divyanshu ;
O'Donnell, James ;
Byrne, Miriam A. .
BUILDING AND ENVIRONMENT, 2025, 276
[37]   Indoor air quality analysis in naturally ventilated university training laboratories: a health risk assessment [J].
Sesena, Susana ;
Rodriguez, Ana M. ;
Palop, M. Llanos .
AIR QUALITY ATMOSPHERE AND HEALTH, 2022, 15 (10) :1817-1837
[38]   Indoor air quality assessment of particulate matter levels in urban homes in India [J].
Vijay, Prince ;
Sahota, Vinayak ;
Singh, Rajdeep ;
Dubey, Shreya ;
Borse, Sonali ;
Phuleria, Harish C. .
ATMOSPHERIC POLLUTION RESEARCH, 2025, 16 (08)
[39]   Human personal air pollution clouds in a naturally ventilated office during the COVID-19 pandemic [J].
Yang, Shen ;
Muthalagu, Akila ;
Serrano, Viviana Gonzalez ;
Licina, Dusan .
BUILDING AND ENVIRONMENT, 2023, 236
[40]   Assessment of indoor air quality in office buildings across Europe - The OFFICAIR study [J].
Mandin, Corinne ;
Trantallidi, Marilena ;
Cattaneo, Andrea ;
Canha, Nuno ;
Mihucz, Victor G. ;
Szigeti, Tamas ;
Mabilia, Rosanna ;
Perreca, Erica ;
Spinazze, Andrea ;
Fossati, Serena ;
De Kluizenaar, Yvonne ;
Cornelissen, Eric ;
Sakellaris, Ioannis ;
Saraga, Dikaia ;
Hanninen, Otto ;
Fernandes, Eduardo De Oliveira ;
Ventura, Gabriela ;
Wolkoff, Peder ;
Carrer, Paolo ;
Bartzis, John .
SCIENCE OF THE TOTAL ENVIRONMENT, 2017, 579 :169-178