Comparison of Indoor Air Quality for Air-Conditioned and Naturally Ventilated Office Spaces in Urban Area

被引:10
作者
Jain, Supreme [1 ]
Garg, Divyam [1 ]
Goel, Anubha [1 ,2 ]
机构
[1] Indian Inst Technol, Dept Civil Engn, Kanpur, Uttar Pradesh, India
[2] Indian Inst Technol, Ctr Environm Sci & Engn, Kanpur, Uttar Pradesh, India
来源
INDOOR ENVIRONMENTAL QUALITY, ACIEQ | 2020年 / 60卷
关键词
IAQ; Office microenvironment; Particles; Ventilation; Activity level; PARTICULATE MATTER; EXPOSURE; PARTICLES; CHILDREN; COARSE; PM;
D O I
10.1007/978-981-15-1334-3_1
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Indoor air quality (IAQ) is affected by indoor pollution sources that release gases or particles into the air and depending on ventilation conditions, outdoor ambient air quality can also be contributing factor. Inadequate ventilation by limiting inflow-outflow of pollutants, proximity to field or busy road can increase indoor pollutant levels. For this study, two offices, one with natural ventilation and other with central AC system, within residential campus of IIT Kanpur were selected. Air quality in offices with varying ventilation conditions was monitored simultaneously indoor and outdoor. The aim was to compare the data for the two locations and elicit influence of ventilation conditions on indoor pollutant levels. Size segregated mass concentration of ambient aerosols and particle number concentration (PNC) were determined for indoor using cascade impactor, MOUDI and OPC, respectively. Outdoor coarse particle concentration (PM10) was determined using HVS sampler. The PM concentration was found to be highest in naturally ventilated office. As per the recently released ISHRAE standards for indoor environment (ISHRAE Standard-10001:2016), minimum acceptable limits for Class C are PM10 < 100 mu g/m(3) and PM2.5 < 25 mu g/m(3). Levels of particles recorded in these office spaces were 4-6 times higher than ISHRAE acceptable limits for PM2.5 and PM10, respectively. Particle number concentration (PNC) was also higher in naturally ventilated office space as concentration was more than 400,000 particles/cm(3) (<1 mu m) as compared to airconditioned office space (160,000 particles/cm(3)). The I/O ratio for PM10 was found to be 0.64 and 2.93 for Office 1 and Office 2, respectively.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 50 条
  • [11] Indoor air quality in naturally ventilated dwellings in Spain
    Garcia-Ortega, Sonia
    Linares-Alemparte, Pilar
    INFORMES DE LA CONSTRUCCION, 2023, 75 (572)
  • [12] Indoor air quality in an air-conditioned building in new Delhi and its relationship to ambient air quality
    Prasad, RK
    Uma, R
    Kansal, A
    Gupta, S
    Kumar, P
    Saksena, S
    INDOOR AND BUILT ENVIRONMENT, 2002, 11 (06) : 334 - 339
  • [13] Effect of natural ventilation and manual airing on indoor air quality in naturally ventilated Italian classrooms
    Stabile, Luca
    Dell'Isola, Marco
    Frattolillo, Andrea
    Massimo, Angelamaria
    Russi, Aldo
    BUILDING AND ENVIRONMENT, 2016, 98 : 180 - 189
  • [14] Feasibility study of an express assessment protocol for the indoor air quality of air-conditioned offices
    Hui, P. S.
    Wong, L. T.
    Mui, K. W.
    INDOOR AND BUILT ENVIRONMENT, 2006, 15 (04) : 373 - 378
  • [15] The Impact of Traffic-Related Air Pollutants on the Indoor Air Quality of a Naturally Ventilated Building
    Tong, Zheming
    Chen, Yujiao
    Malkawi, Ali
    2017 ASHRAE WINTER CONFERENCE PAPERS, 2017,
  • [16] Microbial Air Quality in Air-conditioned Passenger Cars
    Golofit-Szymczak, Malgorzata
    Stobnicka-Kupiec, Agata
    ROCZNIK OCHRONA SRODOWISKA, 2018, 20 : 1564 - 1582
  • [17] Radon and its decay products in an air-conditioned auditorium in correlation with indoor air parameters
    Polednik, Bernard
    Kozak, Krzysztof
    Mazur, Jadwiga
    Dudzinska, Marzenna
    Grzadziel, Dominik
    INDOOR AND BUILT ENVIRONMENT, 2017, 26 (05) : 621 - 630
  • [18] Ventilation characteristics of an air-conditioned office building in Singapore
    Sekhar, SC
    Tham, KW
    Cheong, D
    BUILDING AND ENVIRONMENT, 2002, 37 (03) : 241 - 255
  • [19] Effects of Partition on Thermal Comfort, Indoor Air Quality, Energy Consumption, and Perception in Air-Conditioned Buildings
    Aryal, Pradip
    Leephakpreeda, Thananchai
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2016, 138 (05):
  • [20] Indoor and outdoor particles in an air-conditioned building during and after the 2013 haze in Singapore
    Chen, Ailu
    Cao, Qingliang
    Zhou, Jin
    Yang, Bin
    Chang, Victor W. -C.
    Nazaroff, William W.
    BUILDING AND ENVIRONMENT, 2016, 99 : 73 - 81