Transbronchial lung biopsy - Can specimen quality be predicted at the time of biopsy?

被引:37
作者
Curley, FJ
Johal, JS
Burke, ME
Fraire, AE
机构
[1] Univ Massachusetts, Sch Med, Div Pulm Allergy & Crit Care Med, Worcester, MA USA
[2] Univ Massachusetts, Sch Med, Dept Pathol, Worcester, MA 01605 USA
关键词
alveolar count; bronchoscopy; interstitial fibrosis; lung biopsy;
D O I
10.1378/chest.113.4.1037
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Study objectives: To determine the bronchoscopist's ability to predict specimen quality at the time of transbronchial biopsy and to determine the influence of biopsy specimen size and alveolar content on diagnostic value. Design: Prospective, blinded, observational analysis. Setting: Tertiary care academic hospital-based pulmonary practice. Patients: Forty-three adult patients who underwent transbronchial lung biopsy. Interventions: Each of 170 biopsy specimens was rated as to likelihood of containing diagnostic tissue, size and ability to float, tissue types present, number of alveoli, and pathologic diagnosis. Results: Fifteen percent of biopsy specimens were small and 40% were large. Seventy-six percent of specimens floated; 81.8% of the 170 biopsy specimens contained abnormal lung tissue; and 14.7% of individual specimens were diagnostic. Fifty-two percent of specimens contained >20 alveoli. Larger biopsy specimens were more likely to contain diagnostic tissue (r=0.29, p=0.001). Cup forceps retrieved smaller pieces of tissue (p=0.007) and were less likely to obtain diagnostic tissue (p=0.06). Physician ratings of specimen quality (mean+/-SD) did not differ between specimens containing normal and abnormal tissue (5.98+/-2.3 vs 5.46+/-5.5; p=0.24) or between specimens containing diagnostic vs nondiagnostic tissue (5.56+/-2.5 vs 6.25+/-2.1; p=0.14). Specimens that floated were no more likely to be diagnostic or abnormal than specimens that sank (p<0.05). Diagnosis when established was made by the first biopsy specimen in 53.3% and the second in 33.3% Conclusions: Physician estimate of biopsy specimen quality and the float sign are not helpful in predicting that the biopsy specimen contains abnormal or diagnostic tissue. Diagnostic biopsy specimen will likely be obtained if the size of the specimen fills the forceps, 2 to 4 biopsies are performed, and toothed forceps are used.
引用
收藏
页码:1037 / 1041
页数:5
相关论文
共 8 条
  • [1] EVALUATION OF THE FLOAT SIGN FOR DETERMINING ADEQUACY OF SPECIMENS OBTAINED WITH TRANSBRONCHIAL BIOPSY
    ANDERS, GT
    LINVILLE, KC
    JOHNSON, JE
    BLANTON, HM
    [J]. AMERICAN REVIEW OF RESPIRATORY DISEASE, 1991, 144 (06): : 1406 - 1407
  • [2] TRANSBRONCHIAL LUNG-BIOPSY - HISTOPATHOLOGIC AND MORPHOMETRIC ASSESSMENT OF DIAGNOSTIC UTILITY
    FRAIRE, AE
    COOPER, SP
    GREENBERG, SD
    ROWLAND, LP
    LANGSTON, C
    [J]. CHEST, 1992, 102 (03) : 748 - 752
  • [3] INTERPRETATION AND SIGNIFICANCE OF PATHOLOGIC FINDINGS IN TRANS-BRONCHIAL LUNG-BIOPSY
    KATZENSTEIN, ALA
    ASKIN, FB
    [J]. AMERICAN JOURNAL OF SURGICAL PATHOLOGY, 1980, 4 (03) : 223 - 234
  • [4] LEVIN DC, 1974, AM REV RESPIR DIS, V110, P4
  • [5] POE RH, 1979, AM REV RESPIR DIS, V119, P25
  • [6] DIAGNOSTIC-ACCURACY OF MULTIPLE BIOPSIES FROM FLEXIBLE FIBEROPTIC BRONCHOSCOPY - A COMPARISON OF CENTRAL VERSUS PERIPHERAL CARCINOMA
    POPOVICH, J
    KVALE, PA
    EICHENHORN, MS
    RADKE, JR
    OHORODNIK, JM
    FINE, G
    [J]. AMERICAN REVIEW OF RESPIRATORY DISEASE, 1982, 125 (05): : 521 - 523
  • [7] BRONCHOSCOPY IN NORTH-AMERICA - THE ACCP SURVEY
    PRAKASH, UBS
    OFFORD, KP
    STUBBS, SE
    [J]. CHEST, 1991, 100 (06) : 1668 - 1675
  • [8] TRANS-BRONCHOSCOPIC LUNG-BIOPSY IN SARCOIDOSIS - OPTIMAL NUMBER AND SITES FOR DIAGNOSIS
    ROETHE, RA
    FULLER, PB
    BYRD, RB
    HAFERMANN, DR
    [J]. CHEST, 1980, 77 (03) : 400 - 402