Evaluation of a new polymeric stationary phase with reversed-phase properties for high temperature liquid chromatography

被引:14
作者
Vanhoenacker, Gerd [1 ]
Pereira, Alberto Dos Santos [1 ]
Kotsuka, Takashi [2 ]
Cabooter, Deirdre [3 ]
Desmet, Gert [3 ]
Sandra, Pat [1 ,4 ]
机构
[1] Res Inst Chromatog, B-8500 Kortrijk, Belgium
[2] Showa Denko Co Ltd, Kawasaki Ku, Kanagawa 2100867, Japan
[3] Vrije Univ Brussel, Dept Chem Engn, B-1050 Brussels, Belgium
[4] Univ Ghent, Pfizer Analyt Res Ctr, B-9000 Ghent, Belgium
关键词
Polymeric stationary phase; High temperature; Liquid chromatography; ELEVATED-TEMPERATURE; SMALL MOLECULES; PURE WATER; STABILITY; COLUMN; PERFORMANCE; HPLC; TECHNOLOGY; PRINCIPLES;
D O I
10.1016/j.chroma.2009.09.070
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The performance of a polymeric stationary phase with reversed-phase properties (ET-RP1) was evaluated for LC separations at elevated temperature. The most significant observation was that the reduced plate height (h) decreased from 3.4 at 25 degrees C (optimal flow 0.5 mL/min) to 2.4 at 150 degrees C (optimal flow 2.5 mL/min) which is comparable to the efficiency obtained with silica-based reversed-phase columns of 4.6 mm ID operated at 0.8 mL/min. The phase showed no deterioration after long use at 150 C within the pH range 1-9. Catalytic activity originating from the stationary phase material, e.g. as experienced on zirconium columns operated at elevated temperature, was absent. The performance of ET-RP1 is illustrated with the analysis of some pharmaceutical samples by LC and LC-MS. Operation at elevated temperature also allows to reduce the amount of organic modifier or to replace acetonitrile and methanol by the biodegradable ethanol. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:3217 / 3222
页数:6
相关论文
共 22 条
[1]  
[Anonymous], UNPUB
[2]   High temperature liquid chromatography with monolithic capillary columns and pure water eluent [J].
Causon, Tim J. ;
Shellie, Robert A. ;
Hilder, Emily F. .
ANALYST, 2009, 134 (03) :440-442
[3]   Review on the chemical and thermal stability of stationary phases for reversed-phase liquid chromatography [J].
Claessens, HA ;
van Straten, MA .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1060 (1-2) :23-41
[4]   Zirconia stationary phases for extreme separations [J].
Dunlap, CJ ;
McNeff, CV ;
Stoll, D ;
Carr, PW .
ANALYTICAL CHEMISTRY, 2001, 73 (21) :598A-607A
[5]   Influence of the stationary phase on the stability of thalidomide and comparison of different methods for the quantification of thalidomide in tablets using high-temperature liquid chromatography [J].
Giegold, Sascha ;
Holzhauser, Maren ;
Kiffmeyer, Thekla ;
Tuerk, Jochen ;
Teutenberg, Thorsten ;
Rosenhagen, Maike ;
Hennies, Dorothea ;
Hoppe-Tichy, Torsten ;
Wenclawiak, Bernd .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 46 (04) :625-630
[6]   Effect of temperature in reversed phase liquid chromatography [J].
Guillarme, D ;
Heinisch, S ;
Rocca, JL .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1052 (1-2) :39-51
[7]   Liquid chromatography at elevated temperatures with pure water as the mobile phase [J].
Hartonen, Kari ;
Riekkola, Marja-Liisa .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2008, 27 (01) :1-14
[8]   Sense and nonsense of high-temperature liquid chromatography [J].
Heinisch, Sabine ;
Rocca, Jean-Louis .
JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (04) :642-658
[9]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF SUBSTITUTED PARA-BENZOQUINONES AND PARA-HYDROQUINONES .1. INTERPLAY OF ON-COLUMN REDOX REACTION AND THE CHROMATOGRAPHIC RETENTION PROCESS [J].
HUANG, JX ;
STUART, JD ;
MELANDER, WR ;
HORVATH, C .
JOURNAL OF CHROMATOGRAPHY, 1984, 316 (DEC) :151-161
[10]  
Majors RE, 2000, LC GC N AM, V18, P1214