Postabsorptive hyperglucagonemia in patients with type 2 diabetes mellitus analyzed with a novel enzyme-linked immunosorbent assay

被引:42
作者
Matsuo, Toshihiro [1 ]
Miyagawa, Jun-ichiro [1 ]
Kusunoki, Yoshiki [1 ]
Miuchi, Masayuki [1 ]
Ikawa, Takashi [1 ]
Akagami, Takafumi [1 ]
Tokuda, Masaru [1 ]
Katsuno, Tomoyuki [2 ]
Kushida, Akira [3 ]
Inagaki, Takashi [3 ]
Namba, Mitsuyoshi [1 ]
机构
[1] Hyogo Coll Med, Dept Internal Med, Div Endocrinol Diabet & Metab, Nishinomiya, Hyogo 6638501, Japan
[2] Hyogo Coll Med, Div Innovat Diabet Treatment, Nishinomiya, Hyogo 6638501, Japan
[3] Cosm Corp, Tokyo, Japan
关键词
Glucagon (1-29); Glucagon-like peptides; Type 2 diabetes mellitus; GLUCAGON-LIKE PEPTIDE-1; DEPENDENT INSULINOTROPIC POLYPEPTIDE; POSTPRANDIAL GLUCOSE; CELL FUNCTION; ORAL GLUCOSE; PLASMA; SECRETION; GLICENTIN; OXYNTOMODULIN; HYPERGLYCEMIA;
D O I
10.1111/jdi.12400
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims/introduction: The aims of the present study were to investigate the performance of a novel sandwich enzyme-linked immunosorbent assay (ELISA) for measuring glucagon (1-29) with monoclonal antibodies against both the C-and N-terminal regions of glucagon (1-29), and to analyze the differences in plasma levels and responses of glucagon (1-29) to oral glucose loading in normal glucose tolerance (NGT) subjects and patients with type 2 diabetes mellitus. Materials and Methods: The cross-reactivity against proglucagon fragments using the ELISA kit and two types of conventional radioimmunoassay (RIA) kits was evaluated. A 75-g oral glucose tolerance test was carried out with NGT subjects and patients with type 2 diabetes mellitus, and the glucagon (1-29) concentration was measured using three types of kit. Results: The ELISA kit clearly had the lowest cross-reactivity against miniglucagon (19-29) and glicentin (1-61). The oral glucose tolerance test was carried out with 30 NGT and 17 patients with type 2 diabetes mellitus. The glucagon (1-29) levels measured by the ELISA kit after glucose loading were significantly higher at all time-points in the type 2 diabetes mellitus group than in the NGT group. However, the glucagon (1-29) levels measured by one RIA kit were significantly higher in the NGT group, and those measured with the other RIA kit were approximately the same among the groups. Conclusions: The novel sandwich ELISA accurately determines plasma glucagon (1-29) concentrations with much less cross-reactivity against other proglucagon fragments than conventional RIA kits.
引用
收藏
页码:324 / 331
页数:8
相关论文
共 36 条
[1]   Hyperglucagonaemia analysed by glucagon sandwich ELISA: nonspecific interference or truly elevated levels? [J].
Albrechtsen, Nicolai J. Wewer ;
Hartmann, Bolette ;
Veedfald, Simon ;
Windelov, Johanne A. ;
Plamboeck, Astrid ;
Bojsen-Moller, Kirstine N. ;
Idorn, Thomas ;
Feldt-Rasmussen, Bo ;
Knop, Filip K. ;
Vilsboll, Tina ;
Madsbad, Sten ;
Deacon, Carolyn F. ;
Holst, Jens J. .
DIABETOLOGIA, 2014, 57 (09) :1919-1926
[2]   Glucagon responses to increasing oral loads of glucose and corresponding isoglycaemic intravenous glucose infusions in patients with type 2 diabetes and healthy individuals [J].
Bagger, Jonatan I. ;
Knop, Filip K. ;
Lund, Asger ;
Holst, Jens J. ;
Vilsboll, Tina .
DIABETOLOGIA, 2014, 57 (08) :1720-1725
[3]   Specificity and sensitivity of commercially available assays for glucagon and oxyntomodulin measurement in humans [J].
Bak, Monika J. ;
Albrechtsen, Nicolai Wewer ;
Pedersen, Jens ;
Hartmann, Bolette ;
Christensen, Mikkel ;
Vilsboll, Tina ;
Knop, Filip K. ;
Deacon, Carolyn F. ;
Dragsted, Lars O. ;
Holst, Jens J. .
EUROPEAN JOURNAL OF ENDOCRINOLOGY, 2014, 170 (04) :529-538
[4]   GLICENTIN-1-61 PROBABLY REPRESENTS A MAJOR FRACTION OF GLUCAGON-RELATED PEPTIDES IN PLASMA OF ANESTHETIZED UREMIC PIGS [J].
BALDISSERA, FGA ;
HOLST, JJ .
DIABETOLOGIA, 1986, 29 (07) :462-467
[5]   Pro-protein convertases in intermediary metabolism: islet hormones, brain/gut hormones and integrated physiology [J].
Bataille, Dominique .
JOURNAL OF MOLECULAR MEDICINE-JMM, 2007, 85 (07) :673-684
[6]   The forgotten members of the glucagon family [J].
Bataille, Dominique ;
Dalle, Stephane .
DIABETES RESEARCH AND CLINICAL PRACTICE, 2014, 106 (01) :1-10
[7]  
BLACHE P, 1990, J BIOL CHEM, V265, P21514
[8]   MINIGLUCAGON PRODUCTION FROM GLUCAGON - AN EXTRACELLULAR PROCESSING OF A HORMONE USED AS A PROHORMONE [J].
BLACHE, P ;
KERVRAN, A ;
LENGUYEN, D ;
BATAILLE, D .
BIOCHIMIE, 1994, 76 (3-4) :295-299
[9]   Elevated plasma glucose-dependent insulinotropic polypeptide associates with hyperinsulinemia in metabolic syndrome [J].
Calanna, Salvatore ;
Urbano, Francesca ;
Piro, Salvatore ;
Zagami, Rose Maria ;
Di Pino, Antonino ;
Spadaro, Luisa ;
Purrello, Francesco ;
Rabuazzo, Agata Maria .
EUROPEAN JOURNAL OF ENDOCRINOLOGY, 2012, 166 (05) :917-922
[10]   Glucose-Dependent Insulinotropic Polypeptide A Bifunctional Glucose-Dependent Regulator of Glucagon and Insulin Secretion in Humans [J].
Christensen, Mikkel ;
Vedtofte, Louise ;
Holst, Jens J. ;
Vilsboll, Tina ;
Knop, Filip K. .
DIABETES, 2011, 60 (12) :3103-3109