Physiological Control Law for Rotary Blood Pumps with Full-State Feedback Method

被引:5
作者
Bakouri, Mohsen [1 ,2 ]
机构
[1] Majmaah Univ, Coll Appl Med Sci, Dept Med Equipment Technol, Majmaah City 11952, Saudi Arabia
[2] Sebha Univ, Coll Arts, Dept Phys, Traghen City 71340, Libya
来源
APPLIED SCIENCES-BASEL | 2019年 / 9卷 / 21期
关键词
heart failure; cardiac assist devices; full state feedback; cardiovascular system; pulsatility index; STARLING-LIKE CONTROLLER; HEART-FAILURE; ASSIST; FLOW; SYSTEM; PULSATILITY; MODEL;
D O I
10.3390/app9214593
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
One concern about pulsatile rotary blood pumps is their physiological controller reactions when "venous return" changes. When a patient rises from a supine to a standing position, the blood volume in the leg veins is raised, owing to vasodilation, thus venous returns to the right atrium, and consequently, the left atrium is reduced. In this work, a physiological control law using a full-state feedback control method was developed in order to drive mechanical circulatory support. This strategy was used as a validated state-space pump model, to implement the controller and regulate the desired reference flow. The control law was assessed using a software model of the hemodynamical cardiovascular system interacting with the left ventricular assist device in different physiological conditions ranging from rest to exercise scenarios. Under these scenarios, heart failure disease was simulated by changing the hemodynamic parameters of the total blood volume, heart rate, cardiac contractility, and systemic peripheral resistance. The results were numerically observed during the postural changes. The rate of change in the physiological variables showed that the proposed control law can regulate the desired reference pump flow with minimal error within the acceptable clinical range in order to prevent suction and over perfusion.
引用
收藏
页数:16
相关论文
共 36 条
[1]   Developments in control systems for rotary left ventricular assist devices for heart failure patients: a review [J].
AlOmari, Abdul-Hakeem H. ;
Savkin, Andrey V. ;
Stevens, Michael ;
Mason, David G. ;
Timms, Daniel L. ;
Salamonsen, Robert F. ;
Lovell, Nigel H. .
PHYSIOLOGICAL MEASUREMENT, 2013, 34 (01) :R1-R27
[2]  
Araki K, 1998, ASAIO J, V44, pM708, DOI 10.1097/00002480-199809000-00082
[3]  
BAKOURI M, 2015, ASIA CONTROL CONF AS, P1
[4]   Nonlinear modelling and control of left ventricular assist device [J].
Bakouri, M. A. ;
Savkin, A. V. ;
Alomari, A. H. .
ELECTRONICS LETTERS, 2015, 51 (08) :614-615
[5]  
Bakouri M, 2019, 2019 18TH EUROPEAN CONTROL CONFERENCE (ECC), P221, DOI [10.23919/ECC.2019.8795740, 10.23919/ecc.2019.8795740]
[6]   Evaluation of an advanced model reference sliding mode control method for cardiac assist device using a numerical model [J].
Bakouri, Mohsen .
IET SYSTEMS BIOLOGY, 2018, 12 (02) :68-72
[7]   A Sliding Mode-Based Starling-Like Controller for Implantable Rotary Blood Pumps [J].
Bakouri, Mohsen A. ;
Salamonsen, Robert F. ;
Savkin, Andrey V. ;
AlOmari, Abdul-Hakeem H. ;
Lim, Einly ;
Lovell, Nigel H. .
ARTIFICIAL ORGANS, 2014, 38 (07) :587-593
[8]   Hierarchical control of heart-assist devices [J].
Boston, JR ;
Antaki, JF ;
Simaan, MA .
IEEE ROBOTICS & AUTOMATION MAGAZINE, 2003, 10 (01) :54-64
[9]   Physiologic outcome of varying speed rotary blood pump support algorithms: a review study [J].
Bozkurt, Selim .
AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2016, 39 (01) :13-28
[10]   The evolution of mechanical circulatory support (MCS): a new wave of developments in MCS and heart failure treatment [J].
Chatterjee, Anamika ;
Schmitto, Jan D. .
JOURNAL OF THORACIC DISEASE, 2018, 10 :S1688-S1691