Metal artifacts correction in cone-beam CT bone imaging

被引:0
作者
Zhang, Yan [1 ,2 ]
Ning, Ruola [1 ,2 ]
Conover, David [1 ]
机构
[1] Univ Rochester, Dept Imaging Sci, Rochester, NY 14620 USA
[2] Univ Rochester, Dept Elect & Comp Engn, Rochester, NY 14620 USA
来源
MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3 | 2007年 / 6510卷
关键词
cone-beam CT; metal artifacts; beam-hardening; bone imaging;
D O I
10.1117/12.710165
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Cone-beam CT (CBCT) technique is needed by orthopaedists in their new studies([1,2]) to monitor bone volume growth and blood vessel growth of structural bone grafts used in reconstruction surgery. However, titanium plate and screws, which are commonly used to connect bone grafts to host bones, can cause severe streaking artifacts and shading artifact in the reconstructed images due to their high attenuation of x-rays. These metal artifacts will distort the information of the bone and cause difficulties when measuring bone volume growth and the inside; blood vessel growth. To solve this problem and help orthopaedists quantitatively record the growth of bone grafts we present a three-dimensional metal artifact correction technique to correct the streaking artifacts generated by titanium implants. In this project not only the artifacts need to be corrected but also the correct information of the bone is required in the image for the quantitative measurements. Both phantom studies and animal studies were conducted to test this correction method. Images without metal correction and images with metal correction were compared together, as well as the reference bone images acquired without metal. It's shown the streaking and shading artifacts were greatly reduced after metal correction. The accuracy of bone volume measurements was also greatly increased by 79% for phantom studies and 53% for animal studies.
引用
收藏
页数:9
相关论文
共 10 条
[1]   BEAM HARDENING IN X-RAY RECONSTRUCTIVE TOMOGRAPHY [J].
BROOKS, RA ;
DICHIRO, G .
PHYSICS IN MEDICINE AND BIOLOGY, 1976, 21 (03) :390-398
[2]  
CHEN LM, 2003, P SPIE MED IMAGING, V4684, P841
[3]   AN ALGORITHM FOR THE REDUCTION OF METAL CLIP ARTIFACTS IN CT RECONSTRUCTIONS [J].
GLOVER, GH ;
PELC, NJ .
MEDICAL PHYSICS, 1981, 8 (06) :799-807
[4]   An iterative approach to the beam hardening correction in cone beam CT [J].
Hsieh, J ;
Molthen, RC ;
Dawson, CA ;
Johnson, RH .
MEDICAL PHYSICS, 2000, 27 (01) :23-29
[5]  
Hsieh J., 2003, Computed tomography: principles, design, artifacts, and recent advances
[6]   Remodeling of cortical bone allografts mediated by adherent rAAV-RANKL and VEGF gene therapy [J].
Ito, H ;
Koefoed, M ;
Tiyapatanaputi, P ;
Gromov, K ;
Goater, JJ ;
Carmouche, J ;
Zhang, XP ;
Rubery, PT ;
Rabinowitz, J ;
Samulski, RJ ;
Nakamura, T ;
Soballe, K ;
O'Keefe, RJ ;
Boyce, BF ;
Schwarz, EM .
NATURE MEDICINE, 2005, 11 (03) :291-297
[7]   METHOD FOR CORRECTING BONE INDUCED ARTIFACTS IN COMPUTED TOMOGRAPHY SCANNERS [J].
JOSEPH, PM ;
SPITAL, RD .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1978, 2 (01) :100-108
[8]  
KIJEWSKI P K, 1978, Medical Physics (Woodbury), V5, P209, DOI 10.1118/1.594429
[9]   Biological effects of rAAV-caAlk2 coating on structural allograft healing [J].
Koefoed, M ;
Ito, H ;
Gromov, K ;
Reynolds, DG ;
Awad, HA ;
Rubery, PT ;
Ulrich-Vinther, M ;
Soballe, K ;
Guldberg, RE ;
Lin, ASP ;
O'Keefe, RJ ;
Zhang, XP ;
Schwarz, EM .
MOLECULAR THERAPY, 2005, 12 (02) :212-218
[10]   EVALUATION OF CT TECHNIQUES FOR REDUCING ARTIFACTS IN THE PRESENCE OF METALLIC ORTHOPEDIC IMPLANTS [J].
ROBERTSON, DD ;
WEISS, PJ ;
FISHMAN, EK ;
MAGID, D ;
WALKER, PS .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1988, 12 (02) :236-241