Hybrid membrane processes for the treatment of surface water and mitigation of membrane fouling

被引:27
作者
Zouboulis, A. [1 ]
Zamboulis, D. [1 ]
Szymanska, K. [1 ]
机构
[1] Aristotle Univ Thessaloniki, Dept Chem, Div Chem Technol, GR-54124 Thessaloniki, Greece
关键词
Ceramic membrane filtration; Ozonation; Ozonation coupled with hydrogen peroxide; Hybrid process; Surface water treatment; NATURAL ORGANIC-MATTER; DRINKING-WATER; PERMEATE FLUX; HUMIC ACIDS; OZONATION; FILTRATION; OZONE; ULTRAFILTRATION; OXIDATION; DECOMPOSITION;
D O I
10.1016/j.seppur.2014.09.023
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Membrane-based processes are well recognized treatment methods for waters and wastewaters of different origin. However, the biggest drawback connected with membranes' filtration is their severe fouling, which deteriorates the process effectiveness. Combining membrane filtration with another water/wastewater treatment method in a hybrid process is a promising way of improving the overall membrane operation. In this study an approach of combining ceramic membrane filtration with chemical oxidation processes, i.e. ozonation and ozonation combined with hydrogen peroxide, is presented. A flat sheet ceramic microfiltration membrane of a submerged type has been used in the experimental unit. Ozone oxygen gas mixture was introduced to the system by appropriate ceramic gas spargers and two flow rates of the gas mixture were tested: 0.1 L/min and 0.2 L/min with corresponding ozone dosages of 2.5 and 5.0 mg O-3/min of ozone addition, respectively. The water treated in this experimental system was a simulated (contaminated) surface water with Total Organic Carbon (TOC) content of 8 (+/- 0.3) mg/L and turbidity of 20 (+/- 0.5) NTU. The collected permeates were evaluated for selected pollution parameters, such as turbidity, TOC, UV254 absorbance and SUVA values. HPLC analysis has been performed for the calculation of molecular weights of products in the permeates obtained during hybrid processes. The fouling of membrane was evaluated by the calculation of Fouling Index (FI) and monitoring changes in the Trans Membrane Pressure during membrane operation. The obtained results indicated that the membrane fouling was mitigated during the hybrid processes, increasing the overall efficiency of membrane microfiltration for the treatment of contaminated surface water. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:43 / 52
页数:10
相关论文
共 50 条
  • [41] Ceramic membrane based hybrid process for the upgrade of rural water treatment plants: A pilot study
    Chen, Li
    Li, Jiabin
    Fu, Wanyi
    Zhang, Xihui
    WATER ENVIRONMENT RESEARCH, 2021, 93 (01) : 75 - 83
  • [42] PVDF@CoFe2O4 nanoconfined catalytic membrane for natural surface water treatment: Efficient NOM degradation and membrane fouling mitigation
    Qiu, Liping
    Meng, Fanduo
    Qiu, Qi
    Kang, Xinwei
    Gong, Shuai
    Zhang, Fengxia
    Xu, Jingtao
    Wang, Feihong
    Wu, Daoji
    Zhu, Xuewu
    JOURNAL OF WATER PROCESS ENGINEERING, 2025, 70
  • [43] Membrane fouling in photocatalytic membrane reactors (PMRs) for water and wastewater treatment: A critical review
    Zhang, Wenxiang
    Ding, Luhui
    Luo, Jianquan
    Jaffrin, Michel Y.
    Tang, Bing
    CHEMICAL ENGINEERING JOURNAL, 2016, 302 : 446 - 458
  • [44] Gradient purification of surface water and ultrafiltration membrane fouling mitigation based on Fe(VI) multifunctional integration characteristics: Is a sedimentation unit necessary?
    Chen, Kunyu
    Wang, Jie
    Huang, Xiaojiang
    Mu, Ruimin
    Luo, Congwei
    Wu, Daoji
    Liu, Jing
    Lu, Jinsuo
    Cheng, Xiaoxiang
    WATER RESEARCH, 2025, 280
  • [45] Membrane technology for surface water treatment: advancement from microfiltration to membrane bioreactor
    Li, Lu
    Visvanathan, Chettiyappan
    REVIEWS IN ENVIRONMENTAL SCIENCE AND BIO-TECHNOLOGY, 2017, 16 (04) : 737 - 760
  • [46] Effect of pre-ozonation on nanofiltration membrane fouling during water reuse applications
    Vatankhah, Hooman
    Murray, Conner C.
    Brannum, Jacob W.
    Vanneste, Johan
    Bellona, Christopher
    SEPARATION AND PURIFICATION TECHNOLOGY, 2018, 205 : 203 - 211
  • [47] Influence of the background water matrix on the hybrid ceramic MF/O3 system and correlation between pollutants rejection and membrane fouling
    Szymanska, Katarzyna
    Zouboulis, Anastasios I.
    Zamboulis, Dimitrios
    JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2016, 91 (04) : 958 - 966
  • [48] Recent Mitigation Strategies on Membrane Fouling for Oily Wastewater Treatment
    Zulkefli, Nur Fatihah
    Alias, Nur Hashimah
    Jamaluddin, Nur Shafiqah
    Abdullah, Norfadhilatuladha
    Abdul Manaf, Shareena Fairuz
    Othman, Nur Hidayati
    Marpani, Fauziah
    Mat-Shayuti, Muhammad Shafiq
    Kusworo, Tutuk Djoko
    MEMBRANES, 2022, 12 (01)
  • [49] A review on the applicability of integrated/hybrid membrane processes in water treatment and desalination plants
    Ang, Wei Lun
    Mohammad, Abdul Wahab
    Hilal, Nidal
    Leo, Choe Peng
    DESALINATION, 2015, 363 : 2 - 18
  • [50] Hybrid ion exchange - Pressure driven membrane processes in water treatment: A review
    Al Abdulgader, Hasan
    Kochkodan, Victor
    Hilal, Nidal
    SEPARATION AND PURIFICATION TECHNOLOGY, 2013, 116 : 253 - 264