MEMS sensor array-based electronic nose for breath analysis-a simulation study

被引:13
作者
Gupta, Anurag [1 ]
Singh, T. Sonamani [1 ]
Yadava, R. D. S. [1 ]
机构
[1] Banaras Hindu Univ, Inst Sci, Dept Phys, Sensors & Signal Proc Lab, Varanasi 221005, Uttar Pradesh, India
关键词
breath analysis; electronic nose; MEMS sensor array; sensor functionalization; oxidative stress; hypoxia; diabetes; VOLATILE ORGANIC-COMPOUNDS; LIPID-PEROXIDATION; EXHALED BREATH; CLINICAL-DIAGNOSIS; POLYMER SELECTION; OXIDATIVE STRESS; ETHANE; MARKERS; BIOMARKERS; RESONANCE;
D O I
10.1088/1752-7163/aad5f1
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The paper presents a simulation study of breath analysis based on theoretical models of microelectromechanical structure (MEMS) cantilever sensor array. The purpose of this study is to suggest a methodology for the development of MEMS electronic nose (e-nose) for monitoring disease-specific volatiles in exhaled breath. Oxidative stress and diabetes are taken as case studies for the assessment of e-nose designs. The detection of ethane for general oxidative stress, isoprene for hypoxia, and acetone for diabetes are considered for targeted detection. A number of volatiles concurrently present in the exhaled breath are taken as interferents. The MEMS cantilevers are coated with volatile-selective polymers and are analyzed in both the static and dynamic modes. The sensor array is defined by polymer selections based on three data mining methods: principal component analysis (PCA), fuzzy c-means clustering (FCM), and fuzzy subtractive clustering (FSC). This utilizes vapor/polymer partition coefficients as a database. Analyses are carried out to find optimal combinations of the polymer selection method and cantilever sensing mode. Virtual breath analysis experiments are analyzed by PCA for target discrimination. It is found that no single combination works best in all conditions. The acetone (diabetes) detection is best in both sensing modes with the polymers selected by FSC; the isoprene (hypoxia) is detectable only in static sensing mode with polymers selected by FCM clustering; and the ethane (oxidative stress) detection is possible by all sensing modes and polymer selections, provided the breath samples are preconcentrated. This study suggests that it is difficult to realize a single general-purpose MEMS breath analyzer. The dedicated analyzers for specific disease indications can however be made with an optimal combination of sensing mode and polymer coatings.
引用
收藏
页数:17
相关论文
共 55 条
  • [2] Antioxidant vitamin supplementation in Crohn's disease decreases oxidative stress: A randomized controlled trial
    Aghdassi, E
    Wendland, BE
    Steinhart, AH
    Wolman, SL
    Jeejeebhoy, K
    Allard, JP
    [J]. AMERICAN JOURNAL OF GASTROENTEROLOGY, 2003, 98 (02) : 348 - 353
  • [3] The human volatilome: volatile organic compounds (VOCs) in exhaled breath, skin emanations, urine, feces and saliva
    Amann, Anton
    Costello, Ben de Lacy
    Miekisch, Wolfram
    Schubert, Jochen
    Buszewski, Boguslaw
    Pleil, Joachim
    Ratcliffe, Norman
    Risby, Terence
    [J]. JOURNAL OF BREATH RESEARCH, 2014, 8 (03)
  • [4] Analysis of Exhaled Breath for Disease Detection
    Amann, Anton
    Miekisch, Wolfram
    Schubert, Jochen
    Buszewski, Boguslaw
    Ligor, Tomasz
    Jezierski, Tadeusz
    Pleil, Joachim
    Risby, Terence
    [J]. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY, VOL 7, 2014, 7 : 455 - 482
  • [5] Volatile organic compounds in the exhaled breath of young patients with cystic fibrosis
    Barker, M
    Hengst, M
    Schmid, J
    Buers, HJ
    Mittermaier, B
    Klemp, D
    Koppman, R
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2006, 27 (05) : 929 - 936
  • [6] Exhaled Nitric Oxide in Pulmonary Diseases A Comprehensive Review
    Barnes, Peter J.
    Dweik, Raed A.
    Gelb, Arthur F.
    Gibson, Peter G.
    George, Steven C.
    Grasemann, Hartmut
    Pavord, Ian D.
    Ratjen, Felix
    Silkoff, Philip E.
    Taylor, D. Robin
    Zamel, Noe
    [J]. CHEST, 2010, 138 (03) : 682 - 692
  • [7] Current evidence and future research needs for FeNO measurement in respiratory diseases
    Bjermer, Leif
    Alving, Kjell
    Diamant, Zuzana
    Magnussen, Helgo
    Pavord, Ian
    Piacentini, Giorgio
    Price, David
    Roche, Nicolas
    Sastre, Joaquin
    Thomas, Mike
    Usmani, Omar
    [J]. RESPIRATORY MEDICINE, 2014, 108 (06) : 830 - 841
  • [8] The versatile use of exhaled volatile organic compounds in human health and disease
    Boots, Agnes W.
    van Berkel, Joep J. B. N.
    Dallinga, Jan W.
    Smolinska, Agnieszka
    Wouters, Emile F.
    van Schooten, Frederik J.
    [J]. JOURNAL OF BREATH RESEARCH, 2012, 6 (02)
  • [9] Human exhaled air analytics: Biomarkers of diseases
    Buszewski, Boguslaw
    Kesy, Martyna
    Ligor, Tomasz
    Amann, Anton
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2007, 21 (06) : 553 - 566
  • [10] Buszewski B, 2013, VOLATILE BIOMARKERS: NON-INVASIVE DIAGNOSIS IN PHYSIOLOGY AND MEDICINE, P177, DOI 10.1016/B978-0-44-462613-4.00010-6