Simultaneous voltammetric determination of carbendazim and carbaryl in medicinal plant infusions with a boron-doped diamond electrode

被引:6
作者
Lima, Thays de Souza [1 ]
Simoes, Fabio Ruiz [2 ]
Codognoto, Lucia [1 ]
机构
[1] Univ Fed Sao Paulo, Inst Ciencias Ambientais Quim & Farmaceut, Dept Ciencias Exatas & Terra, Diadema, Brazil
[2] Univ Fed Sao Paulo, Dept Ciencias Mar, Santos, Brazil
基金
巴西圣保罗研究基金会;
关键词
Carbendazim; carbaryl; simultaneous determination; boron-doped diamond electrode; Mikania glomerata infusions; DIFFERENTIAL-PULSE VOLTAMMETRY; SQUARE-WAVE VOLTAMMETRY; TRADITIONAL CHINESE MEDICINE; TANDEM MASS-SPECTROMETRY; CARBON-PASTE ELECTRODE; NATURAL-WATERS; ELECTROANALYTICAL DETERMINATION; ELECTROCHEMICAL DETERMINATION; SENSITIVE DETERMINATION; MULTIRESIDUE METHOD;
D O I
10.1080/03067319.2017.1354992
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study is aimed to develop an electroanalytical methodology using a boron-doped diamond electrode to determine simultaneously and selectively carbendazim (CBZ) and carbaryl (CAR). In previous studies using cyclic voltammetry oxidation, peaks were observed at 1.03V (CBZ) and 1.44V (CAR), with characteristics of an irreversible process controlled by diffusion of species, with a supporting electrolyte of BR buffer (0.1mol L-1) and pH adjusted to 6.0. The differences between the potentials for both pesticides, about 400mV, indicate the possibility of selective determination of CBZ and CAR. The square-wave voltammetric parameters were optimised. The best separation conditions were pH 6.0, square-wave frequency of 100s(-1), pulse amplitude of 50mV and scan increment of 2.0mV. These parameters were used to obtain the calibration curves of CBZ and CAR. An analytical curve was constructed in the range concentration of CBZ of 1.3mg L-1 to 15.3mg L-1 and CAR of 1.0mg L-1 to 11.4mg L-1, respectively. The limits of detection (LOD) and limits of quantification (LOQ) for CBZ were 0.40mg L-1 and 1.30mg L-1, respectively. For CAR, the LOD and LOQ were 0.30mg L-1 and 1.00mg L-1, respectively. Sensitivity values were 0.78 and 2.60 mu A/mg L-1 for CBZ and CAR, respectively. The electroanalytical method was applied in Mikania glomerata infusions. The recovery values were 106.2% and 116.5% for CBZ and CAR, respectively. The results show that the developed method is suitable for application in medicinal plant samples.
引用
收藏
页码:768 / 782
页数:15
相关论文
共 50 条
  • [41] Voltammetric Determination of Amino Derivatives of Naphthalene Using Boron-Doped Diamond Film Electrode
    Zavazalova, Jaroslava
    Dejmkova, Hana
    Barek, Jiri
    Peckova, Karolina
    XXXII. MODERNI ELEKTROCHEMICKE METODY, 2012, : 159 - 162
  • [42] Voltammetric determination of plant hormone indole-3-butyric acid in acidic media employing boron-doped diamond electrode
    Chylkova, Jaromira
    Janikova, Lenka
    Sedlak, Milos
    Vana, Jiri
    Selesovska, Renata
    MONATSHEFTE FUR CHEMIE, 2019, 150 (03): : 443 - 449
  • [43] Voltammetric determination of harmaline in natural food products using boron-doped diamond electrode
    Svorc, L'ubomir
    Cinkova, Kristina
    Samphao, Anchalee
    Stankovic, Dalibor M.
    Mehmeti, Eda
    Kalcher, Kurt
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2015, 744 : 37 - 44
  • [44] VOLTAMMETRIC DETERMINATION OF CARCINOGENIC DERIVATIVES OF PYRENE USING A BORON-DOPED DIAMOND FILM ELECTRODE
    Yosypchuk, Oksana
    Barek, Jiri
    Vyskocil, Vlastimil
    ANALYTICAL LETTERS, 2012, 45 (5-6) : 449 - 459
  • [45] Boron-doped Diamond Electrodes for Voltammetric Determination of Benzophenone-3
    Zavazalova, Jaroslava
    Prochazkova, Katerina
    Schwarzova-Peckova, Karolina
    ANALYTICAL LETTERS, 2016, 49 (01) : 80 - 91
  • [46] Sensitive square-wave voltammetric determination of tadalafil (Cialis®) in pharmaceutical samples using a cathodically pretreated boron-doped diamond electrode
    Sartori, Elen Romao
    Clausen, Debora Nobile
    Ruiz Pires, Igor Matheus
    Rossi Salamanca-Neto, Carlos Alberto
    DIAMOND AND RELATED MATERIALS, 2017, 77 : 153 - 158
  • [47] Voltammetric Determination of Antidepressant Imipramine in Pharmaceutical Preparations Using Boron-Doped Diamond Electrode
    Cinkova, Kristina
    Matokarova, Martina
    Salusova, Ivana
    Plankova, Alexandra
    Brtkova, Barbora
    Borovska, Katarina
    Marton, Marian
    Vojs, Marian
    Svorc, L'ubomir
    CHEMICKE LISTY, 2017, 111 (06): : 392 - 397
  • [48] Voltammetric determination of mixtures of caffeine and chlorogenic acid in beverage samples using a boron-doped diamond electrode
    Yardim, Yavuz
    Keskin, Ertugrul
    Senturk, Zuhre
    TALANTA, 2013, 116 : 1010 - 1017
  • [49] Square-Wave Adsorptive Stripping Voltammetric Determination of Hesperidin Using a Boron-Doped Diamond Electrode
    Yigit, Aydin
    Yardim, Yavuz
    Senturk, Zuhre
    JOURNAL OF ANALYTICAL CHEMISTRY, 2020, 75 (05) : 653 - 661
  • [50] Sensitive voltammetric method for rapid determination of pyridine herbicide triclopyr on bare boron-doped diamond electrode
    Janikova-Bandzuchova, Lenka
    Selesovska, Renata
    Schwarzova-Peckova, Karolina
    Chylkova, Jaromira
    ELECTROCHIMICA ACTA, 2015, 154 : 421 - 429