Simultaneous voltammetric determination of carbendazim and carbaryl in medicinal plant infusions with a boron-doped diamond electrode

被引:6
作者
Lima, Thays de Souza [1 ]
Simoes, Fabio Ruiz [2 ]
Codognoto, Lucia [1 ]
机构
[1] Univ Fed Sao Paulo, Inst Ciencias Ambientais Quim & Farmaceut, Dept Ciencias Exatas & Terra, Diadema, Brazil
[2] Univ Fed Sao Paulo, Dept Ciencias Mar, Santos, Brazil
基金
巴西圣保罗研究基金会;
关键词
Carbendazim; carbaryl; simultaneous determination; boron-doped diamond electrode; Mikania glomerata infusions; DIFFERENTIAL-PULSE VOLTAMMETRY; SQUARE-WAVE VOLTAMMETRY; TRADITIONAL CHINESE MEDICINE; TANDEM MASS-SPECTROMETRY; CARBON-PASTE ELECTRODE; NATURAL-WATERS; ELECTROANALYTICAL DETERMINATION; ELECTROCHEMICAL DETERMINATION; SENSITIVE DETERMINATION; MULTIRESIDUE METHOD;
D O I
10.1080/03067319.2017.1354992
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study is aimed to develop an electroanalytical methodology using a boron-doped diamond electrode to determine simultaneously and selectively carbendazim (CBZ) and carbaryl (CAR). In previous studies using cyclic voltammetry oxidation, peaks were observed at 1.03V (CBZ) and 1.44V (CAR), with characteristics of an irreversible process controlled by diffusion of species, with a supporting electrolyte of BR buffer (0.1mol L-1) and pH adjusted to 6.0. The differences between the potentials for both pesticides, about 400mV, indicate the possibility of selective determination of CBZ and CAR. The square-wave voltammetric parameters were optimised. The best separation conditions were pH 6.0, square-wave frequency of 100s(-1), pulse amplitude of 50mV and scan increment of 2.0mV. These parameters were used to obtain the calibration curves of CBZ and CAR. An analytical curve was constructed in the range concentration of CBZ of 1.3mg L-1 to 15.3mg L-1 and CAR of 1.0mg L-1 to 11.4mg L-1, respectively. The limits of detection (LOD) and limits of quantification (LOQ) for CBZ were 0.40mg L-1 and 1.30mg L-1, respectively. For CAR, the LOD and LOQ were 0.30mg L-1 and 1.00mg L-1, respectively. Sensitivity values were 0.78 and 2.60 mu A/mg L-1 for CBZ and CAR, respectively. The electroanalytical method was applied in Mikania glomerata infusions. The recovery values were 106.2% and 116.5% for CBZ and CAR, respectively. The results show that the developed method is suitable for application in medicinal plant samples.
引用
收藏
页码:768 / 782
页数:15
相关论文
共 50 条
  • [31] Voltammetric determination of leucovorin in pharmaceutical preparations using a boron-doped diamond electrode
    Selesovska, Renata
    Krankova, Barbora
    Stepankova, Michaela
    Martinkova, Pavlina
    Janikova, Lenka
    Chylkova, Jaromira
    Navratil, Tomas
    MONATSHEFTE FUR CHEMIE, 2018, 149 (09): : 1701 - 1708
  • [32] Voltammetric determination of caffeine in beverage samples on bare boron-doped diamond electrode
    Svorc, Lubomir
    Tomcik, Peter
    Svitkova, Jana
    Rievaj, Miroslav
    Bustin, Dusan
    FOOD CHEMISTRY, 2012, 135 (03) : 1198 - 1204
  • [33] Voltammetric determination of wedelolactone, an anti-HIV herbal drug, at boron-doped diamond electrode
    Saxena, Sachin
    Shrivastava, Ratnanjali
    Satsangee, Soami P.
    JOURNAL OF CHEMICAL SCIENCES, 2015, 127 (05) : 959 - 966
  • [34] Voltammetric Determination of Ethionamide in Pharmaceutical Formulations and Human Urine using a Boron-Doped Diamond Electrode
    Ferraz, Bruno R. L.
    Leite, Fernando R. F.
    Batista, Bruna L.
    Malagutti, Andrea R.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2016, 27 (04) : 677 - 684
  • [35] Electroanalytical application of a boron-doped diamond electrode: Improving the simultaneous voltammetric determination of amlodipine and valsartan in urine and combined dosage forms
    Mansano, Guilherme Roberto
    Aires Eisele, Ana Paula
    Dall'Antonia, Luiz Henrique
    Afonso, Sabrina
    Sartori, Elen Romao
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2015, 738 : 188 - 194
  • [36] Direct and simultaneous determination of phenol, hydroquinone and nitrophenol at boron-doped diamond film electrode
    Zhao Guo-Hua
    Tang Yi-Ting
    Liu Mei-Chuan
    Lei Yan-Zhu
    Xiao Xiao-E
    CHINESE JOURNAL OF CHEMISTRY, 2007, 25 (10) : 1445 - 1450
  • [37] SIMULTANEOUS VOLTAMMETRIC DETERMINATION OF AMLODIPINE BESYLATE AND HYDROCHLOROTHIAZIDE IN SYNTHETIC URINE SAMPLES USING A BORON-DOPED DIAMOND ELECTRODE
    Silva, Lais Pereira
    Lourencao, Bruna C.
    Fatibello-Filho, Orlando
    QUIMICA NOVA, 2015, 38 (06): : 801 - 806
  • [38] Imipramine sensing in pharmaceutical formulations using boron-doped diamond electrode
    Oliveira, Sameque N.
    Ribeiro, Francisco W. P.
    Sousa, Camila P.
    Soares, Janete Eliza S.
    Suffredini, Hugo B.
    Becker, Helena
    de Lima-Neto, Pedro
    Correia, Adriana N.
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 788 : 118 - 124
  • [39] Boron-doped Diamond Film Electrode as Voltammetric Sensor for Cetirizine
    Culkova, Eva
    Lukacova-Chomistekova, Zuzana
    Bellova, Renata
    Melichercikova, Danica
    Durdiak, Jaroslav
    Timko, Jaroslav
    Rievaj, Miroslav
    Tomcik, Peter
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (07): : 6358 - 6372
  • [40] β-Cyclodextrin and multiwalled carbon nanotubes modified boron-doped diamond electrode for voltammetric assay of carbendazim and its corrosion inhibition behavior on stainless steel
    Brycht, Mariola
    Vajdle, Olga
    Sipa, Karolina
    Robak, Justyna
    Rudnicki, Konrad
    Piechocka, Justyna
    Tasic, Ana
    Skrzypek, Sawomira
    Guzsvany, Valeria
    IONICS, 2018, 24 (03) : 923 - 934