Simultaneous voltammetric determination of carbendazim and carbaryl in medicinal plant infusions with a boron-doped diamond electrode

被引:6
作者
Lima, Thays de Souza [1 ]
Simoes, Fabio Ruiz [2 ]
Codognoto, Lucia [1 ]
机构
[1] Univ Fed Sao Paulo, Inst Ciencias Ambientais Quim & Farmaceut, Dept Ciencias Exatas & Terra, Diadema, Brazil
[2] Univ Fed Sao Paulo, Dept Ciencias Mar, Santos, Brazil
基金
巴西圣保罗研究基金会;
关键词
Carbendazim; carbaryl; simultaneous determination; boron-doped diamond electrode; Mikania glomerata infusions; DIFFERENTIAL-PULSE VOLTAMMETRY; SQUARE-WAVE VOLTAMMETRY; TRADITIONAL CHINESE MEDICINE; TANDEM MASS-SPECTROMETRY; CARBON-PASTE ELECTRODE; NATURAL-WATERS; ELECTROANALYTICAL DETERMINATION; ELECTROCHEMICAL DETERMINATION; SENSITIVE DETERMINATION; MULTIRESIDUE METHOD;
D O I
10.1080/03067319.2017.1354992
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study is aimed to develop an electroanalytical methodology using a boron-doped diamond electrode to determine simultaneously and selectively carbendazim (CBZ) and carbaryl (CAR). In previous studies using cyclic voltammetry oxidation, peaks were observed at 1.03V (CBZ) and 1.44V (CAR), with characteristics of an irreversible process controlled by diffusion of species, with a supporting electrolyte of BR buffer (0.1mol L-1) and pH adjusted to 6.0. The differences between the potentials for both pesticides, about 400mV, indicate the possibility of selective determination of CBZ and CAR. The square-wave voltammetric parameters were optimised. The best separation conditions were pH 6.0, square-wave frequency of 100s(-1), pulse amplitude of 50mV and scan increment of 2.0mV. These parameters were used to obtain the calibration curves of CBZ and CAR. An analytical curve was constructed in the range concentration of CBZ of 1.3mg L-1 to 15.3mg L-1 and CAR of 1.0mg L-1 to 11.4mg L-1, respectively. The limits of detection (LOD) and limits of quantification (LOQ) for CBZ were 0.40mg L-1 and 1.30mg L-1, respectively. For CAR, the LOD and LOQ were 0.30mg L-1 and 1.00mg L-1, respectively. Sensitivity values were 0.78 and 2.60 mu A/mg L-1 for CBZ and CAR, respectively. The electroanalytical method was applied in Mikania glomerata infusions. The recovery values were 106.2% and 116.5% for CBZ and CAR, respectively. The results show that the developed method is suitable for application in medicinal plant samples.
引用
收藏
页码:768 / 782
页数:15
相关论文
共 50 条
  • [21] Voltammetric determination of sodium cyclamate in dietary products using a boron-doped diamond electrode
    Medeiros, Roberta Antigo
    de Carvalho, Adriana Evaristo
    Rocha-Filho, Romeu C.
    Fatibello-Filho, Orlando
    QUIMICA NOVA, 2008, 31 (06): : 1405 - 1409
  • [22] Simultaneous voltammetric determination of synthetic colorants in food using a cathodically pretreated boron-doped diamond electrode
    Medeiros, Roberta A.
    Lourencao, Bruna C.
    Rocha-Filho, Romeu C.
    Fatibello-Filho, Orlando
    TALANTA, 2012, 97 : 291 - 297
  • [23] Simultaneous voltammetric determination of paracetamol and ascorbic acid using a boron-doped diamond electrode modified with Nafion and lead films
    Tyszczuk-Rotko, Katarzyna
    Beczkowska, Ilona
    Wojciak-Kosior, Magdalena
    Sowa, Ireneusz
    TALANTA, 2014, 129 : 384 - 391
  • [24] Electrochemical determination of bisphenol A using a boron-doped diamond electrode
    Pereira, Gabriel F.
    Andrade, Leonardo S.
    Rocha-Filho, Romeu C.
    Bocchi, Nerilso
    Biaggio, Sonia R.
    ELECTROCHIMICA ACTA, 2012, 82 : 3 - 8
  • [25] Simultaneous Differential Pulse Voltammetric Determination of Ascorbic Acid and Caffeine in Pharmaceutical Formulations Using a Boron-Doped Diamond Electrode
    Lourencao, Bruna Claudia
    Medeiros, Roberta Antigo
    Rocha-Filho, Romeu C.
    Fatibello-Filho, Orlando
    ELECTROANALYSIS, 2010, 22 (15) : 1717 - 1723
  • [26] Simultaneous Voltammetric Determination of Benzene, Toluene and Xylenes (BTX) in Water Using a Cathodically Pre-treated Boron-doped Diamond Electrode
    de Freitas Junior, Geraldo Garcia
    Florencio, Tayla M.
    Mendonca, Ricardo J.
    Salazar-Banda, Giancarlo R.
    Oliveira, Robson T. S.
    ELECTROANALYSIS, 2019, 31 (03) : 554 - 559
  • [27] Simultaneous Voltammetric Determination of Antihypertensive Drugs Amlodipine and Atenolol in Pharmaceuticals Using a Cathodically Pretreated Boron-Doped Diamond Electrode
    Moraes, Jaqueline T.
    Eisele, Ana P. P.
    Salamanca-Neto, Carlos A. R.
    Scremin, Jessica
    Sartori, Elen R.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2016, 27 (07) : 1264 - 1272
  • [28] Voltammetric determination of leucovorin in pharmaceutical preparations using a boron-doped diamond electrode
    Renáta Šelešovská
    Barbora Kränková
    Michaela Štěpánková
    Pavlína Martinková
    Lenka Janíková
    Jaromíra Chýlková
    Tomáš Navrátil
    Monatshefte für Chemie - Chemical Monthly, 2018, 149 : 1701 - 1708
  • [29] Voltammetric Determination of Caffeine in Commercial Beverages on Bare Boron-Doped Diamond Electrode
    Svorc, Lubomir
    Svitkova, Jana
    Tomcik, Peter
    Rievaj, Miroslav
    Bustin, Dusan
    XXXII. MODERNI ELEKTROCHEMICKE METODY, 2012, : 138 - 142
  • [30] Comparison of the paracetamol electrochemical determination using boron-doped diamond electrode and boron-doped carbon nanowalls
    Niedzialkowski, P.
    Cebula, Z.
    Malinowska, N.
    Bialobrzeska, W.
    Sobaszek, M.
    Ficek, M.
    Bogdanowicz, R.
    Anand, J. Sein
    Ossowski, T.
    BIOSENSORS & BIOELECTRONICS, 2019, 126 : 308 - 314