Simultaneous voltammetric determination of carbendazim and carbaryl in medicinal plant infusions with a boron-doped diamond electrode

被引:6
作者
Lima, Thays de Souza [1 ]
Simoes, Fabio Ruiz [2 ]
Codognoto, Lucia [1 ]
机构
[1] Univ Fed Sao Paulo, Inst Ciencias Ambientais Quim & Farmaceut, Dept Ciencias Exatas & Terra, Diadema, Brazil
[2] Univ Fed Sao Paulo, Dept Ciencias Mar, Santos, Brazil
基金
巴西圣保罗研究基金会;
关键词
Carbendazim; carbaryl; simultaneous determination; boron-doped diamond electrode; Mikania glomerata infusions; DIFFERENTIAL-PULSE VOLTAMMETRY; SQUARE-WAVE VOLTAMMETRY; TRADITIONAL CHINESE MEDICINE; TANDEM MASS-SPECTROMETRY; CARBON-PASTE ELECTRODE; NATURAL-WATERS; ELECTROANALYTICAL DETERMINATION; ELECTROCHEMICAL DETERMINATION; SENSITIVE DETERMINATION; MULTIRESIDUE METHOD;
D O I
10.1080/03067319.2017.1354992
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This study is aimed to develop an electroanalytical methodology using a boron-doped diamond electrode to determine simultaneously and selectively carbendazim (CBZ) and carbaryl (CAR). In previous studies using cyclic voltammetry oxidation, peaks were observed at 1.03V (CBZ) and 1.44V (CAR), with characteristics of an irreversible process controlled by diffusion of species, with a supporting electrolyte of BR buffer (0.1mol L-1) and pH adjusted to 6.0. The differences between the potentials for both pesticides, about 400mV, indicate the possibility of selective determination of CBZ and CAR. The square-wave voltammetric parameters were optimised. The best separation conditions were pH 6.0, square-wave frequency of 100s(-1), pulse amplitude of 50mV and scan increment of 2.0mV. These parameters were used to obtain the calibration curves of CBZ and CAR. An analytical curve was constructed in the range concentration of CBZ of 1.3mg L-1 to 15.3mg L-1 and CAR of 1.0mg L-1 to 11.4mg L-1, respectively. The limits of detection (LOD) and limits of quantification (LOQ) for CBZ were 0.40mg L-1 and 1.30mg L-1, respectively. For CAR, the LOD and LOQ were 0.30mg L-1 and 1.00mg L-1, respectively. Sensitivity values were 0.78 and 2.60 mu A/mg L-1 for CBZ and CAR, respectively. The electroanalytical method was applied in Mikania glomerata infusions. The recovery values were 106.2% and 116.5% for CBZ and CAR, respectively. The results show that the developed method is suitable for application in medicinal plant samples.
引用
收藏
页码:768 / 782
页数:15
相关论文
共 50 条
  • [1] Simultaneous voltammetric determination of phenolic antioxidants in food using a boron-doped diamond electrode
    Medeiros, Roberta Antigo
    Rocha-Filho, Romeu C.
    Fatibello-Filho, Orlando
    FOOD CHEMISTRY, 2010, 123 (03) : 886 - 891
  • [2] Simultaneous Voltammetric Detection of Carbaryl and Paraquat Pesticides on Graphene-Modified Boron-Doped Diamond Electrode
    Pop, Aniela
    Manea, Florica
    Flueras, Adriana
    Schoonman, Joop
    SENSORS, 2017, 17 (09):
  • [3] Voltammetric Method for the Simultaneous Determination of Melatonin and Pyridoxine in Dietary Supplements Using a Cathodically Pretreated Boron-doped Diamond Electrode
    Alpar, Nurcan
    Pinar, Pinar Talay
    Yardim, Yavuz
    Senturk, Zuehre
    ELECTROANALYSIS, 2017, 29 (07) : 1691 - 1699
  • [4] Simultaneous Differential Pulse Voltammetric Determination of Sulfamethoxazole and Trimethoprim on a Boron-Doped Diamond Electrode
    Andrade, Leonardo S.
    Rocha-Filho, Romeu C.
    Cass, Quezia B.
    Fatibello-Filho, Orlando
    ELECTROANALYSIS, 2009, 21 (13) : 1475 - 1480
  • [5] Voltammetric determination of erythromycin in water samples using a boron-doped diamond electrode
    Radicova, Monika
    Behul, Miroslav
    Vojs, Marian
    Bodor, Robert
    Stanova, Andrea Vojs
    PHYSICA STATUS SOLIDI B-BASIC SOLID STATE PHYSICS, 2015, 252 (11): : 2608 - 2613
  • [6] Simultaneous voltammetric determination of paracetamol and caffeine in pharmaceutical formulations using a boron-doped diamond electrode
    Lourencao, Bruna Claudia
    Medeiros, Roberta Antigo
    Rocha-Filho, Romeu C.
    Mazo, Luiz Henrique
    Fatibello-Filho, Orlando
    TALANTA, 2009, 78 (03) : 748 - 752
  • [7] Voltammetric Determination of Benzophenone-3 at Boron-Doped Diamond Electrode
    Zavazalova, Jaroslava
    Prochazkova, Katerina
    Nezbedova, Michaela
    Peckova, Karolina
    XXXIV. MODERNI ELEKTROCHEMICKE METODY, 2014, : 242 - 245
  • [8] Voltammetric and amperometric determination of metoclopramide on boron-doped diamond film electrode
    Dejmkova, Hana
    Dag, Candan
    Barek, Jiri
    Zima, Jiri
    CENTRAL EUROPEAN JOURNAL OF CHEMISTRY, 2012, 10 (04): : 1310 - 1317
  • [9] Simple and rapid voltammetric determination of cephalosporin drug cefixime on boron-doped diamond electrode
    Keskin, Ertugrul
    Allahverdiyeva, Shabnam
    Seker, Hamza
    Yardim, Yavuz
    MONATSHEFTE FUR CHEMIE, 2019, 150 (11): : 1895 - 1902
  • [10] Simultaneous square-wave voltammetric determination of aspartame and cyclamate using a boron-doped diamond electrode
    Medeiros, Roberta Antigo
    de Carvalho, Adriana Evaristo
    Rocha-Filho, Romeu C.
    Fatibello-Filho, Orlando
    TALANTA, 2008, 76 (03) : 685 - 689