Visual grading characteristics (VGC) analysis:: a non-parametric rank-invariant statistical method for image quality evaluation

被引:223
作者
Bath, M.
Mansson, L. G.
机构
[1] Sahlgrens Univ Hosp, Dept Med Phys & Biomed Engn, SE-41301 Gothenburg, Sweden
[2] Univ Gothenburg, Dept Radiat Phys, SE-41301 Gothenburg, Sweden
关键词
D O I
10.1259/bjr/35012658
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Visual grading of the reproduction of important anatomical structures is often used to determine clinical image quality in radiography. However, many visual grading methods incorrectly use statistical methods that require data belonging to an interval scale. The rating data from the observers in a visual grading study with multiple ratings is ordinal, meaning that non-parametric rank-invariant statistical methods are required. This paper describes such a method for determining the difference in image quality between two modalities called visual grading characteristics (VGC) analysis. In a VGC study, the task of the observer is to rate his confidence about the fulfilment of image quality criteria. The rating data for the two modalities are then analysed in a manner similar to that used in receiver operating characteristics (ROC) analysis. The resulting measure of image quality is the VGC curve, which - for all possible thresholds of the observer for a fulfilled criterion - describes the relationship between the proportions of fulfilled image criteria for the two compared modalities. The area under the VGC curve is proposed as a single measure of the difference in image quality between two compared modalities. It is also described how VGC analysis can be applied to data from an absolute visual grading analysis study.
引用
收藏
页码:169 / 176
页数:8
相关论文
共 36 条
  • [21] MANSSON LG, 1994, THESIS GOTEBORG U GO
  • [22] METZ CE, 1986, INVEST RADIOL, V21, P720, DOI 10.1097/00004424-198609000-00009
  • [23] Evaluation of the Commission of the European Communities quality criteria for the paediatric lateral spine
    Offiah, AC
    Hall, CM
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2003, 76 (912) : 885 - 890
  • [24] Demonstration of correlations between clinical and physical image quality measures in chest and lumbar spine screen-film radiography
    Sandborg, M
    Tingberg, A
    Dance, DR
    Lanhede, B
    Almén, A
    McVey, G
    Sund, P
    Kheddache, S
    Besjakov, J
    Mattsson, S
    Månsson, LG
    Carlsson, GA
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2001, 74 (882) : 520 - 528
  • [25] Comparison of model predictions of image quality with results of clinical trials in chest and lumbar spine screen-film imaging
    Sandborg, M
    McVey, G
    Dance, DR
    Carlsson, GA
    [J]. RADIATION PROTECTION DOSIMETRY, 2000, 90 (1-2) : 173 - 176
  • [26] Sonn U, 1997, SCAND J REHABIL MED, V29, P233
  • [27] Comparison of visual grading analysis and determination of detective quantum efficiency for evaluating system performance in digital chest radiography
    Sund, P
    Båth, M
    Kheddache, S
    Månsson, LG
    [J]. EUROPEAN RADIOLOGY, 2004, 14 (01) : 48 - 58
  • [28] Sund P, 2000, PROC SPIE, V3981, P251, DOI 10.1117/12.383116
  • [29] ASSESSING DIAGNOSTIC TECHNOLOGIES - REPLY
    SWETS, JA
    PICKETT, RM
    [J]. SCIENCE, 1980, 207 (4438) : 1416 - 1416
  • [30] SWETS JA, 1982, EVALUATION DIAGNOST