Evaluating Estrogen Receptor Immunohistochemistry on Cell Blocks From Breast Cancer Patients in a Low-Resource Setting

被引:6
作者
Kimambo, Asteria H. [1 ]
Vuhahula, Edda A. [1 ]
Mwakigonja, Amos R. [1 ]
Ljung, Britt-Marie [2 ]
Li Zhang [3 ,4 ,5 ]
Van Loon, Katherine [4 ,5 ]
Ng, Dianna L. [2 ,5 ,6 ]
机构
[1] Muhimbili Univ Hlth & Allied Sci, Dept Pathol, Dar Es Salaam, Tanzania
[2] Univ Calif San Francisco, Dept Pathol, San Francisco Med Ctr, San Francisco, CA 94143 USA
[3] Univ Calif San Francisco, Dept Epidemiol & Biostat, San Francisco Med Ctr, San Francisco, CA 94143 USA
[4] Univ Calif San Francisco, Dept Med, San Francisco Med Ctr, Div Hematol & Oncol, San Francisco, CA 94143 USA
[5] Univ Calif San Francisco, Helen Diller Family Comprehens Canc Ctr, San Francisco Med Ctr, San Francisco, CA 94143 USA
[6] Mem Sloan Kettering Canc Ctr, Dept Pathol, 1275 York Ave, New York, NY 10065 USA
关键词
NEEDLE-ASPIRATION BIOPSY; PROGESTERONE-RECEPTORS; CLINICAL ONCOLOGY/COLLEGE; AMERICAN SOCIETY; EXPRESSION; CARCINOMAS; FORMALIN; RECOMMENDATIONS; SURVIVAL; CORE;
D O I
10.5858/arpa.2020-0086-OA
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Context.-Breast cancer biomarker assessment is critical in determining treatment and prognosis. In Tanzania, immunohistochemistry (IHC) is limited to surgical specimens and core biopsies. However, performing IHC on fine-needle aspiration biopsy cell blocks would offer numerous advantages. Objective.-To compare the performance between estrogen receptor (ER) IHC performed at Muhimbili National Hospital (MNH) in Tanzania and ER IHC performed at University of California, San Francisco (UCSF), to demonstrate feasibility of performing IHC using cell blocks in Tanzania. Design.-Patients with breast masses were recruited prospectively from the fine-needle aspiration biopsy clinic at MNH. Estrogen receptor IHC results on cell blocks, performed at both MNH and UCSF, and corresponding tissue blocks, performed at MNH, were compared to determine concordance. Results.-Eighty-six cell blocks were evaluated by ER IHC at MNH, with 41 of 86 (47.7%) positive and 45 of 86 (52.3%) negative. Among 65 UCSF and MNH cell block pairs, overall ER IHC concordance was 93.8% (61 of 65) and positive concordance was 93.5% (29 of 31) (kappa = 0.88, P > .99). Among 43 paired UCSF cell blocks and MNH tissue blocks, overall ER IHC concordance was 88.3% (38 of 43) and positive concordance was 90.5% (19 of 21) (kappa = 0.77, P > .99). We compared 62 MNH cell block and tissue block pairs. Overall ER IHC concordance was 90.3% and positive concordance was 87.9% (kappa = 0.81, P = .69). Conclusions.-Pairwise comparisons between ER IHC at MNH, on cell blocks and tissue blocks, with ER IHC at UCSF on cell blocks showed excellent concordance. We demonstrate that ER IHCon fine-needle aspiration biopsy specimens can be implemented in resource-constrained settings.
引用
收藏
页码:834 / 841
页数:8
相关论文
共 40 条
  • [1] Abe O, 2005, LANCET, V366, P2087, DOI 10.1016/s0140-6736(05)66544-0
  • [2] Improvement of pathology in sub-Saharan Africa
    Adesina, Adekunle
    Chumba, David
    Nelson, Ann M.
    Orem, Jackson
    Roberts, Drucilla J.
    Wabinga, Henry
    Wilson, Michael
    Rebbeck, Timothy R.
    [J]. LANCET ONCOLOGY, 2013, 14 (04) : E152 - E157
  • [3] Aisagbonhi O, 2018, AM J CLIN PATHOL, V150, P137, DOI [10.1093/ajcp/aqy031, 10.1093/AJCP/AQY031]
  • [4] Differences in biological features of breast cancer between Caucasian (Italian) and African (Tanzanian) populations
    Amadori, D.
    Serra, P.
    Bravaccini, S.
    Farolfi, A.
    Puccetti, M.
    Carretta, E.
    Medri, L.
    Nanni, O.
    Tumedei, M. M.
    Kahima, J.
    Masalu, N.
    [J]. BREAST CANCER RESEARCH AND TREATMENT, 2014, 145 (01) : 177 - 183
  • [5] Amin MB, 2017, AJCC cancer staging manual, Veighth
  • [6] A Superior Method for Cell Block Preparation for Fine-Needle Aspiration Biopsies
    Balassanian, Ronald
    Wool, Geoffrey D.
    Ono, Jill C.
    Olejnik-Nave, Jolanta
    Mah, Molinda M.
    Sweeney, Brenda J.
    Liberman, Hava
    Ljung, Britt-Marie
    Pitman, Martha B.
    [J]. CANCER CYTOPATHOLOGY, 2016, 124 (07) : 508 - 518
  • [7] Fine needle aspirate cell blocks are reliable for detection of hormone receptors and HER-2 by immunohistochemistry in breast carcinoma
    Bueno Angela, S. P.
    Viero, R. M.
    Soares, C. T.
    [J]. CYTOPATHOLOGY, 2013, 24 (01) : 26 - 32
  • [8] Burson Ashley M, 2010, Breast Dis, V31, P33, DOI 10.3233/BD-2009-0296
  • [9] Trends in 5-year survival rates among breast cancer patients by hormone receptor status and stage
    Chen, Lu
    Linden, Hannah M.
    Anderson, Benjamin O.
    Li, Christopher I.
    [J]. BREAST CANCER RESEARCH AND TREATMENT, 2014, 147 (03) : 609 - 616
  • [10] The state of cell block variation and satisfaction in the era of molecular diagnostics and personalized medicine
    Crapanzano, John P.
    Heymann, Jonas J.
    Monaco, Sara
    Nassar, Aziza
    Saqi, Anjali
    [J]. CYTOJOURNAL, 2014, 11