Remarkable removal of beta-2-microglobulin by on-line hemodiafiltration

被引:64
|
作者
Lornoy, W
Becaus, I
Billiouw, JM
Sierens, L
van Malderen, P
机构
[1] OL Vrouwziekenhuis, Renal Unit, B-9300 Aalst, Belgium
[2] OL Vrouwziekenhuis, Cent Lab, B-9300 Aalst, Belgium
关键词
beta-2-microglobulin; hemodiafiltration; dialysis-related amyloidosis; high-flux hemodialysis membranes;
D O I
10.1159/000013317
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Eight chronic, anuric hemodialysis patients were randomly treated with a high-flux polysulphone dialyzer (F80), using 6 different modes: conventional bicarbonate hemodialysis (HD), hemodiafiltration (HDF) with a replacement solution at 40, 60, 80 or 100 ml/min in postdilution and 80 ml/min in predilution. The differences in beta(2)-microglobulin (beta 2M) reduction ratio and clearance were evaluated statistically by analysis of variance (ANOVA). Both studies revealed no significant difference between HD and HDF40 in postdilution, but an increasing significant difference from HDF60 to HDF100 in postdilution and with HDF80 in predilution. The mean reduction ratio ranged from 49.7 (HD) to 72.7% (HDF 100 ml/min), showing an overall statistically significant difference (p = 0.0000). For the clearance, the range was between 63.8 (HD) and 116.8 ml/min (HDF 100 ml/min) (p = 0.0000). beta 2M in the effluent dialysate with HDF100 ml/min reached up to a mean of 258 mg/session. Concerning small molecules (BUN, creatinine and P), there was a statistically significant different clearance for creatinine and especially for P with HDF 100 ml/min. Conclusion: HDF with an on-line replacement solution at 100 ml/min and a high-flux and biocompatible polysulphone membrane represents a new tool for enhanced removal of beta 2M. Besides a significant increase in creatinine and especially in phosphorus clearance is noted.
引用
收藏
页码:105 / 108
页数:4
相关论文
共 50 条
  • [1] Long-term on-line hemodiafiltration reduces predialysis beta-2-microglobulin levels in chronic hemodialysis patients
    Lin, CL
    Yang, CW
    Chiang, CC
    Chang, CT
    Huang, CC
    BLOOD PURIFICATION, 2001, 19 (03) : 301 - 307
  • [2] The removal of beta-2-microglobulin by an immunoadsorption wall
    Yang, TH
    Lee, CJ
    Chu, IM
    Hwang, JC
    Yang, TL
    ARTIFICIAL ORGANS, 1999, 23 (02) : 131 - 138
  • [3] HIGH-FLUX SYNTHETIC VERSUS CELLULOSIC MEMBRANES FOR BETA-2-MICROGLOBULIN REMOVAL DURING HEMODIALYSIS, HEMODIAFILTRATION AND HEMOFILTRATION
    FLOEGE, J
    GRANOLLERAS, C
    DESCHODT, G
    HECK, M
    BAUDIN, G
    BRANGER, B
    TOURNIER, O
    REINHARD, B
    EISENBACH, GM
    SMEBY, LC
    KOCH, KM
    SHALDON, S
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 1989, 4 (07) : 653 - 657
  • [4] Clinical usefulness of frequent short-time hemodiafiltration: Trial for the effective removal of beta-2-microglobulin
    Kubo, S
    Date, H
    NEPHRON, 1996, 72 (01): : 93 - 97
  • [5] THE EFFECTS OF REPROCESSING HIGH-FLUX POLYSULFONE DIALYZERS WITH PEROXYACETIC ACID ON BETA-2-MICROGLOBULIN REMOVAL IN HEMODIAFILTRATION
    KERR, PG
    ARGILES, A
    CANAUD, B
    FLAVIER, JL
    MION, C
    AMERICAN JOURNAL OF KIDNEY DISEASES, 1992, 19 (05) : 433 - 438
  • [6] In Vitro Removal of Beta-2-Microglobulin From Uremic Blood With an Immunoadsorption Wall
    Yang, Tsung-Hua
    Lin, Bo-Jhou
    Ma, Yi-Ling
    Chou, Kang-Ju
    ARTIFICIAL ORGANS, 2012, 36 (01) : 78 - 86
  • [7] Assessment of the stability of an immunoadsorbent for the extracorporeal removal of beta-2-microglobulin from blood
    Daniels, CM
    Woolverton, EM
    Sprague, SM
    Ameer, GA
    BLOOD PURIFICATION, 2005, 23 (04) : 287 - 297
  • [8] On-line hemodiafiltration
    Ward, RA
    NIEREN-UND HOCHDRUCKKRANKHEITEN, 1999, 28 (01) : 18 - 24
  • [9] Interaction of β2-microglobulin mechanisms of convection, diffusion and adsorption in on-line hemodiafiltration
    García, H
    Hernández-Jaras, J
    Maduell, F
    Yago, M
    Calvo, C
    Ferrero, JA
    NEFROLOGIA, 2000, 20 (01): : 59 - 65
  • [10] BETA-2-MICROGLOBULIN IN POSTMENOPAUSAL OSTEOPOROSIS
    RICO, H
    RIPOLL, E
    REVILLA, M
    RELEA, P
    VILLA, LF
    CALCIFIED TISSUE INTERNATIONAL, 1993, 53 (02) : 78 - 80