Effects of personal particulate matter on peak expiratory flow rate of asthmatic children

被引:35
|
作者
Tang, Chin-Sheng
Chang, Li-Te
Lee, Hsien-Chi
Chan, Chang-Chuan
机构
[1] Fu Jen Catholic Univ, Coll Med, Dept Publ Hlth, Hsinchuang 24205, Taipei County, Taiwan
[2] Feng Chia Univ, Dept Environm Engn, Taichung 40724, Taiwan
[3] Natl Taiwan Univ, Coll Publ Hlth, Inst Occupat Med & Ind Hyg, Taipei 10764, Taiwan
关键词
particulate matter; coarse particle; peak expiratory flow rate; personal exposures; asthmatic children;
D O I
10.1016/j.scitotenv.2007.04.016
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Many researches have shown that the particulate matter (PM) of air pollution could affect the pulmonary functions, especially for susceptible groups such as asthmatic children, where PM might decrease the lung function to different extents. To assess the effects of PM on health, most studies use data from ambient air monitoring sites to represent personal exposure levels. However, the data gathered from these fixed sites might introduce certain statistical uncertainties. The objectives of this study are to evaluate the effects of various size ranges of PM on peak expiratory flow rate (PEFR) of asthmatic children, and to compare the model performance of using different PM measurements (personal exposures versus fixed-site monitoring) in evaluation. Thirty asthmatic children, aged 6 to 12 years, who live near the fixed monitoring site in Sin-Chung City, Taipei County, Taiwan, were recruited for the study. Personal exposures to PM1, PM2.5, and PM10 were measured continuously using a portable particle monitor (GRIMM Mode 1.108, Germany). In addition, an activity diary and questionnaires were used to investigate possible confounding factors in their home environments. The peak expiratory flow rate of each participant was monitored daily in the morning and in the evening for two weeks. Results showed several trends, although not necessarily statistically significant, between personal PM exposures and PEFR measurements in asthmatic children. In general, notable findings tend to implicate that not only fine particles (PM2.5) but also coarse particles (PM2.5-10) are likely to contribute to the exacerbation of asthmatic conditions. Stronger lagged effect and cumulative effect of PM on the decrements in morning PEER were also found in the study. Finally, results of linear mixed-effect model analysis suggested that personal PM data was more suitable for the assessment of change in children's PEFR than ambient monitoring data. (C) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:43 / 51
页数:9
相关论文
共 50 条
  • [21] A Curvilinear Nomogram of Peak Expiratory Flow Rate for the Young
    Wun, Y. T.
    Chan, Mark S. H.
    Wong, Nai Ming
    Kong, Albert Y. F.
    Lam, Tai Pong
    JOURNAL OF ASTHMA, 2013, 50 (01) : 39 - 44
  • [22] Peak expiratory flow (PEF) in monitoring children with asthma
    Cicak, B.
    Verona, E.
    Stefanovic, I. Mihatov
    PAEDIATRIA CROATICA, 2008, 52 (02) : 55 - 63
  • [23] Peak expiratory flow rate of rural school children from Wardha district, Maharashtra in India
    Taksande, Amar
    Jain, Manish
    Vilhekar, Krishna
    Chaturvedi, Pushpa
    WORLD JOURNAL OF PEDIATRICS, 2008, 4 (03) : 211 - 214
  • [24] The anthropometric determinants of peak expiratory flow rate among children in Dar Es Salaam, Tanzania
    Willbroad Kyejo
    Nancy Matillya
    Neelam Ismail
    Gloria Gachocha
    Hajaj Salum
    Rosebella Iseme
    Mariam Noorani
    BMC Pediatrics, 24
  • [25] The anthropometric determinants of peak expiratory flow rate among children in Dar Es Salaam, Tanzania
    Kyejo, Willbroad
    Matillya, Nancy
    Ismail, Neelam
    Gachocha, Gloria
    Salum, Hajaj
    Iseme, Rosebella
    Noorani, Mariam
    BMC PEDIATRICS, 2024, 24 (01)
  • [26] Peak expiratory flow rate of rural school children from Wardha district, Maharashtra in India
    Amar Taksande
    Manish Jain
    Krishna Vilhekar
    Pushpa Chaturvedi
    World Journal of Pediatrics, 2008, 4 : 211 - 214
  • [27] Annual Change of Peak Expiratory Flow Rate in Asthma and COPD
    Hong, Sung Chul
    Lee, Choi
    Han, Jang Soo
    Kim, Won Dong
    Lee, Kye Young
    Kim, Sun Jong
    Kim, Hee Joung
    Ha, Kyoung-Won
    Chon, Gyu Rak
    Yoo, Kwang Ha
    TUBERCULOSIS AND RESPIRATORY DISEASES, 2012, 72 (01) : 24 - 29
  • [28] Association between Peak Expiratory Flow Rate and Exposure Level to Indoor PM2.5 in Asthmatic Children, Using Data from the Escort Intervention Study
    Kim, Sungroul
    Lee, Jungeun
    Park, Sujung
    Rudasingwa, Guillaume
    Lee, Sangwoon
    Yu, Sol
    Lim, Dae Hyun
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (20) : 1 - 11
  • [29] The effect of a mechanical glottis on peak expiratory flow rate and time to peak flow during a peak expiratory flow manoeuvre: A study in normal subjects and patients with motor neurone disease
    Suleman, M
    Abaza, KT
    Gornall, C
    Kinnear, WJM
    Wills, JS
    Mahajan, RP
    ANAESTHESIA, 2004, 59 (09) : 872 - 875
  • [30] The standard range of peak expiratory flow rates of Korean children
    Seo, Won Hee
    Ahn, So Hyun
    Park, Su Hwa
    Kim, Jihyun
    Ahn, Kang Mo
    Ko, Bock Ja
    Lee, Sang Il
    ASIAN PACIFIC JOURNAL OF ALLERGY AND IMMUNOLOGY, 2011, 29 (02): : 143 - 149