Assessment of depth of myometrial invasion by endometrial carcinoma: comparison of T2-weighted SE and contrast-enhanced dynamic GRE MR imaging

被引:28
|
作者
Savci, G
Ozyaman, T
Tutar, M
Bilgin, T
Erol, O
Tuncel, E
机构
[1] Uludag Univ, Fac Med, Dept Radiol, TR-16059 Bursa, Turkey
[2] Uludag Univ, Fac Med, Dept Obstet & Gynecol, TR-16059 Bursa, Turkey
[3] Uludag Univ, Fac Med, Dept Pathol, TR-16059 Bursa, Turkey
关键词
magnetic resonance; contrast enhancement; rapid imaging; comparative studies;
D O I
10.1007/s003300050365
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A prospective study was undertaken to assess the value of both T2-weighted spin-echo (SE) and contrast-enhanced dynamic gradient-echo (GRE) sequences using MR imaging in differentiating the deep myometrial invasion from lower stages produced by endometrial carcinoma. For the correlation of MR findings with the histopathologic findings, patients who had no myomotrial invasion (stage 1 a) and patients in whom tumors were confined to the superficial myometrium (stage 1 b) at pathologic examination were combined as lower stages. Twenty patients with endometrial carcinoma were studied using both techniques. The absence of any detectable tumor (stage 1 a) or the presence of a tumor confined to inner half of myometrium (stage 1 b) and extention of tumor to the outer half of myometrium (stage 1 c) were used as the diagnostic criteria. In pathologic examination of excised specimens, deep myometrial invasion was detected in 9 of 20 patients. The sensitivity, specificity, accuracy positive predictive values (PPV) and negative predictive values (NPV) of T2-weighted SE in differentiating deep myometrial invasion from combined lower stages were 88, 91, 90, 88, and 91 %, respectively, whereas corresponding values for contrast-enhanced dynamic GRE sequences were 78, 100, 90, 100, and 85 %. Statistical difference between two sequences did not reach a significant level. We conclude that in cases of absence of visible junctional zone with SE sequence, contrast-enhanced dynamic GRE MR imaging may be helpful.
引用
收藏
页码:218 / 223
页数:6
相关论文
共 50 条
  • [1] Assessment of depth of myometrial invasion by endometrial carcinoma: comparison of T2-weighted SE and contrast-enhanced dynamic GRE MR imaging
    G. Savci
    T. Ozyaman
    M. Tutar
    T. Bilgin
    O. Erol
    E. Tuncel
    European Radiology, 1998, 8 : 218 - 223
  • [2] Comparison of T2-weighted imaging, diffusion-weighted imaging and contrast-enhanced T1-weighted MR imaging for evaluating perianal fistulas
    Baik, Jiyeon
    Kim, Seung Ho
    Lee, Yedaun
    Yoon, Jung-Hee
    CLINICAL IMAGING, 2017, 44 : 16 - 21
  • [3] Localization of prostate cancer using 3T MRI - Comparison of T2-weighted and dynamic contrast-enhanced imaging
    Kim, CK
    Park, BK
    Kim, B
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2006, 30 (01) : 7 - 11
  • [4] FOCAL LIVER-DISEASE - COMPARISON OF DYNAMIC CONTRAST-ENHANCED CT AND T2-WEIGHTED FAT-SUPPRESSED, FLASH, AND DYNAMIC GADOLINIUM-ENHANCED MR IMAGING AT 1.5T
    SEMELKA, RC
    SHOENUT, JP
    KROEKER, MA
    GREENBERG, HM
    SIMM, FC
    MINUK, GY
    KROEKER, RM
    MICFLIKIER, AB
    RADIOLOGY, 1992, 184 (03) : 687 - 694
  • [5] SOLITARY HEPATIC METASTASIS - COMPARISON OF DYNAMIC CONTRAST-ENHANCED CT AND MR-IMAGING WITH FAT-SUPPRESSED T2-WEIGHTED, BREATH-HOLD T1-WEIGHTED FLASH, AND DYNAMIC GADOLINIUM-ENHANCED FLASH SEQUENCES
    SEMELKA, RC
    SHOENUT, JP
    ASCHER, S
    KROEKER, MA
    GREENBERG, HM
    YAFFE, CS
    MICFLIKIER, AB
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (03): : 319 - 323
  • [6] BLADDER-TUMOR STAGING - COMPARISON OF CONTRAST-ENHANCED CT, T1-WEIGHTED AND T2-WEIGHTED MR-IMAGING, DYNAMIC GADOLINIUM-ENHANCED IMAGING, AND LATE GADOLINIUM-ENHANCED IMAGING
    KIM, BH
    SEMELKA, RC
    ASCHER, SM
    CHALPIN, DB
    CARROLL, PR
    HRICAK, H
    RADIOLOGY, 1994, 193 (01) : 239 - 245
  • [7] Myometrial invasion by endometrial carcinoma: evaluation with 3.0T MR imaging
    Kaneda, Sachi
    Fujii, Shinya
    Fukunaga, Takeru
    Kakite, Suguru
    Kaminou, Toshio
    Kigawa, Junzo
    Harada, Tasuku
    Ogawa, Toshihide
    ABDOMINAL IMAGING, 2011, 36 (05): : 612 - 618
  • [8] Dynamic contrast-enhanced subtraction versus T2-weighted spin-echo MR imaging in the follow-up of colorectal neoplasm: A prospective study of 41 patients
    Kinkel, K
    Tardivon, AA
    Soyer, P
    Spatz, A
    Lasser, P
    Rougier, P
    Vanel, D
    RADIOLOGY, 1996, 200 (02) : 453 - 458
  • [9] ABDOMINAL MR IMAGING - COMPARISON OF T2-WEIGHTED FAST AND CONVENTIONAL SPIN-ECHO, AND CONTRAST-ENHANCED FAST MULTIPLANAR SPOILED GRADIENT-RECALLED IMAGING
    LOW, RN
    FRANCIS, IR
    SIGETI, JS
    FOO, TKF
    RADIOLOGY, 1993, 186 (03) : 803 - 811
  • [10] ACUTE STROKE IN CATS - COMPARISON OF DYNAMIC SUSCEPTIBILITY-CONTRAST MR-IMAGING WITH T2-WEIGHTED AND DIFFUSION-WEIGHTED MR-IMAGING
    MAEDA, M
    ITOH, S
    IDE, H
    MATSUDA, T
    KOBAYASHI, H
    KUBOTA, T
    ISHII, Y
    RADIOLOGY, 1993, 189 (01) : 227 - 232