Automated detection of small pulmonary nodules in whole lung CT scans

被引:26
作者
Enquobahrie, Andinet A.
Reeves, Anthony P.
Yankelevitz, David F.
Henschke, Claudia I.
机构
[1] Cornell Univ, Sch Elect & Comp Engn, Ithaca, NY 14850 USA
[2] Cornell Univ, Weill Med Coll, Dept Radiol, New York, NY 10021 USA
关键词
CT; pulmonary nodules; compute-aided detection (CAD); segmentation; classification; lung cancer screening;
D O I
10.1016/j.acra.2007.01.029
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. The objective of this work was to develop and evaluate a robust algorithm that automatically detects small solid pulmonary nodules in whole lung helical CT scans from a lung cancer screening study. Materials and Methods. We developed a three-stage detection algorithm for both isolated and attached nodules. The algorithm consisted of nodule search space demarcation, nodule candidates' generation, and a sequential elimination of false positives. Isolated nodules are nodules that are surrounded by lung parenchyma, whereas attached nodules are connected to large, dense structures such as pleural and/or mediastinal surface. Two large well-documented whole lung CT scan databases (Databases A and B) were created to train and test the detection algorithm. Database A contains 250 sequentially selected scans with 2.5-mm slice thickness that were obtained at Weill Medical College of Cornell University. With equipment upgrade at this college, a second database, Database B, was created containing 250 scans with a 1.25-mm slice thickness. A total of 395 and 482 nodules were identified in Databases A and B, respectively. In both databases, the majority of the nodules were isolated, comprising 72.1% and 82.3% of nodules in Databases A and B, respectively. Results. The detection algorithm was trained and tested on both Databases A and B. For isolated nodules with sizes 4 mm or larger, the algorithm achieved 94.0% sensitivity and 7.1 false positives per case (FPPC) for Database A (2.5 mm). Similarly, the algorithm achieved 91% sensitivity and 6.9 FPPC for Database B (1.25 mm). The algorithm achieved 92% sensitivity with 17.4 FPPC and 89% sensitivity with 5.5 FFPC for attached nodules with sizes 3 mm or larger in the Database A (2.5 mm) and Database B (1.25 mm), respectively. Conclusion. The developed algorithm achieved practical performance for automated detection of both isolated and the more challenging attached nodules. The automated system will be a useful tool to assist radiologists in identifying nodules from whole lung CT scans in a clinical setting.
引用
收藏
页码:579 / 593
页数:15
相关论文
共 18 条
  • [1] *AM CANC SOC, 2000, CANC FACTS FIG 2006
  • [2] Computerized scheme for automated detection of lung nodules in low-dose computed tomography images for lung cancer screening
    Arimura, H
    Katsuragawa, S
    Suzuki, K
    Li, F
    Shiraishi, J
    Sone, S
    Doi, K
    [J]. ACADEMIC RADIOLOGY, 2004, 11 (06) : 617 - 629
  • [3] Three-dimensional approach to lung nodule detection in helical CT
    Armato, SG
    Giger, ML
    Blackburn, JT
    Doi, K
    MacMahon, H
    [J]. MEDICAL IMAGING 1999: IMAGE PROCESSING, PTS 1 AND 2, 1999, 3661 : 553 - 559
  • [4] Patient-specific models for lung nodule detection and surveillance in CT images
    Brown, MS
    McNitt-Gray, MF
    Goldin, JG
    Suh, RD
    Sayre, JW
    Aberle, DR
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (12) : 1242 - 1250
  • [5] GROUND-GLASS OPACITY OF THE LUNG PARENCHYMA - A GUIDE TO ANALYSIS WITH HIGH-RESOLUTION CT
    ENGELER, CE
    TASHJIAN, JH
    TRENKNER, SW
    WALSH, JW
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (02) : 249 - 251
  • [6] Recognition method of lung nodules using blood vessel extraction techniques and 3D object models
    Fukano, G
    Takizawa, H
    Shigemoto, K
    Yamamoto, S
    Matsumoto, T
    Tateno, Y
    Iinuma, T
    [J]. MEDICAL IMAGING 2003: IMAGE PROCESSING, PTS 1-3, 2003, 5032 : 190 - 198
  • [7] Computerized lung nodule detection on thoracic CT images: combined rule-based and statistical classifier for false positive reduction
    Gurcan, MN
    Petrick, N
    Sahiner, B
    Chan, HP
    Cascade, PN
    Kazerooni, EA
    Hadjiiski, LM
    [J]. MEDICAL IMAGING: 2001: IMAGE PROCESSING, PTS 1-3, 2001, 4322 : 686 - 692
  • [8] CT screening for lung cancer - Assessing a regimen's diagnostic performance
    Henschke, CI
    Yankelevitz, DF
    Smith, JP
    Libby, D
    Pasmantier, M
    McCauley, D
    McGuinness, G
    Naidich, DP
    Farooqi, A
    Vasquez, M
    Miettinen, OS
    [J]. CLINICAL IMAGING, 2004, 28 (05) : 317 - 321
  • [9] CT screening for lung cancer: Frequency and significance of part-solid and nonsolid nodules
    Henschke, CI
    Yankelevitz, DF
    Mirtcheva, R
    McGuinness, G
    McCauley, D
    Miettinen, OS
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 178 (05) : 1053 - 1057
  • [10] Early Lung Cancer Action Project: overall design and findings from baseline screening
    Henschke, CI
    McCauley, DI
    Yankelevitz, DF
    Naidich, DP
    McGuinness, G
    Miettinen, OS
    Libby, DM
    Pasmantier, MW
    Koizumi, J
    Altorki, NK
    Smith, JP
    [J]. LANCET, 1999, 354 (9173) : 99 - 105