Short intra-aortic balloon pump in a swine model of myocardial ischaemia: a proof-of-concept study

被引:3
作者
Gelsomino, Sandro [1 ,2 ]
Lozekoot, Pieter W. J. [1 ]
Lorusso, Roberto [1 ]
de Jong, Monique M. J. [1 ]
Parise, Orlando [1 ]
Matteucci, Francesco [1 ]
Luca, Fabiana [1 ,2 ]
La Meir, Mark [1 ,3 ]
Gensini, Gian Franco [2 ]
Maessen, Jos G. [1 ]
机构
[1] Maastricht Univ, Med Ctr, NL-6200 MD Maastricht, Netherlands
[2] Careggi Univ Hosp, Florence, Italy
[3] Univ Hosp, Dept Cardiothorac Surg, Brussels, Belgium
关键词
Ischaemia; Myocardial infarction; Intra-aortic counterpulsation; CARDIAC CONTRACTILE EFFICIENCY; CORONARY BLOOD-FLOW; PORCINE MODEL; COMPLICATIONS; COUNTERPULSATION; RISK;
D O I
10.1093/ejcts/ezv271
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This proof-of-concept study examined the haemodynamic performance as well as the coronary and visceral organ perfusion using a new short balloon for intra-aortic counterpulsation (IABP) in a swine model of myocardial ischaemia. Eighteen healthy pigs underwent 120-min ligation of the left anterior descending coronary artery followed by 6 h of reperfusion, and they were randomly assigned into 3 groups undergoing IABP implantation with a 35-ml short balloon (n = 6), a 40-ml short balloon (n = 6) or no IABP implantation (controls, n = 6). Haemodynamics, and visceral and coronary flows were measured at baseline (t(0)), at 2 h of ischaemia (t(1)) and every hour thereafter until 6 h of reperfusion (from t(R1) to t(R6)), respectively. Mesenteric and renal flows increased significantly at t(R1) only in the IABP groups (all, P < 0.001) and were significantly higher than controls throughout the reperfusion periods (P < 0.001). Coronary systolic and diastolic blood flows increased only at t(R1) in the IABP groups (all, P < 0.001) but were higher than controls at t(R1)-t(R6). The IABP was associated with enhanced haemodynamics compared with controls. No difference was detected using different balloon volumes (all, P > 0.05). The new short balloon significantly increased visceral flow, enhanced haemodynamics and improved coronary circulation during reperfusion following myocardial ischaemia in our experimental model.
引用
收藏
页码:901 / 909
页数:9
相关论文
共 19 条
[1]   Vascular complications of the intraaortic balloon pump in patients undergoing open heart operations: 15-year experience [J].
Arafa, OE ;
Pedersen, TH ;
Svennevig, JL ;
Fosse, E ;
Geiran, OR .
ANNALS OF THORACIC SURGERY, 1999, 67 (03) :645-651
[2]   In-hospital complications of percutaneous intraaortic balloon counterpulsation [J].
Arceo, A ;
Urban, P ;
Dorsaz, PA ;
Chatelain, P ;
Verin, V ;
Suilen, C ;
Rombaut, E ;
Chevrolet, JC .
ANGIOLOGY, 2003, 54 (05) :577-585
[3]   The intraaortic balloon pump in cardiac surgery [J].
Baskett, RJF ;
Ghali, WA ;
Maitland, A ;
Hirsch, GM .
ANNALS OF THORACIC SURGERY, 2002, 74 (04) :1276-1287
[4]   Increase in coronary blood flow by intra-aortic balloon counterpulsation in a porcine model of myocardial reperfusion [J].
Bonios, Michael J. ;
Pierrakos, Charalampos N. ;
Argiriou, Michael ;
Dalianis, Argirios ;
Terrovitis, John V. ;
Dolou, Paraskevi ;
Drakos, Stavros G. ;
Koudoumas, Dimitrios ;
Charitos, Christos E. ;
Anastasiou-Nana, Maria I. .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2010, 138 (03) :253-260
[5]   Potential Risk for Intra-Aortic Balloon-Induced Obstruction to the Celiac Axis or the Renal Artery in the Asian Population [J].
Byon, H-J ;
Kim, H. ;
Kim, H-C ;
Kim, J-T ;
Kim, H-S ;
Lee, S-C ;
Kim, C. S. .
THORACIC AND CARDIOVASCULAR SURGEON, 2011, 59 (02) :99-102
[6]   Trends in intraaortic balloon counterpulsation complications and outcomes in cardiac surgery [J].
Christenson, JT ;
Cohen, M ;
Ferguson, JJ ;
Freedman, RJ ;
Miller, MF ;
Ohman, M ;
Reddy, RC ;
Stone, GW ;
Urban, PM .
ANNALS OF THORACIC SURGERY, 2002, 74 (04) :1086-1090
[7]   Complications related to intra-aortic balloon pump in cardiac surgery: A decade later [J].
Elahi, MM ;
Chetty, GK ;
Kirke, R ;
Azeem, T ;
Hartshorne, R ;
Spyt, TJ .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2005, 29 (06) :591-594
[8]   Effects of 1:1, 1:2 or 1:3 intra-aortic balloon counterpulsation/heart support on coronary haemodynamics and cardiac contractile efficiency in an animal model of myocardial ischaemia/reperfusion [J].
Gelsomino, Sandro ;
Renzulli, Attilio ;
Rubino, Antonino S. ;
Romano, Salvatore Mario ;
Luca, Fabiana ;
Valente, Serafina ;
Gensini, Gian Franco ;
Lorusso, Roberto .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2012, 42 (02) :325-332
[9]   Increased Coronary Blood Flow and Cardiac Contractile Efficiency With Intraaortic Balloon Counterpulsation in a Porcine Model of Myocardial Ischemia-Reperfusion Injury [J].
Gelsomino, Sandro ;
Luca, Fabiana ;
Renzulli, Attilio ;
Rubino, Antonino S. ;
Romano, Salvatore Mario ;
van der Veen, Frederik H. ;
Carella, Rocco ;
Maessen, Joseph G. ;
Gensini, Gian Franco ;
Lorusso, Roberto .
ASAIO JOURNAL, 2011, 57 (05) :375-381
[10]  
HARVEY JC, 1981, CIRCULATION, V64, P114