Comparison of linear and angular changes assessed in digital dental models and cone-beam computed tomography

被引:7
|
作者
Massaro, Camila [1 ,2 ]
Losada, Carolina [3 ]
Cevidanes, Lucia [1 ]
Yatabe, Marilia [1 ]
Garib, Daniela [4 ]
Pereira Lauris, Jose Roberto [5 ]
Ioshida, Marcos [6 ]
Rey, Diego [7 ]
Antonia Alvarez, Maria [7 ]
Benavides, Erika [8 ]
Rios, Hector [8 ]
Fernando Aristizabal, Juan [3 ]
Ruellas, Antonio Carlos [1 ,9 ]
机构
[1] Univ Michigan, Sch Dent, Dept Orthodont & Pediat Dent, 1011 North Univ Ave, Ann Arbor, MI 48109 USA
[2] Univ Sao Paulo, Bauru Dent Sch, Dept Orthodont, Bauru, Brazil
[3] Univ Valle, Dept Orthodont, Cali, Colombia
[4] Univ Sao Paulo, Bauru Dent Sch & Hosp Rehabil Craniofacial Anomal, Dept Orthodont, Bauru, Brazil
[5] Univ Sao Paulo, Bauru Dent Sch, Dept Community Hlth, Bauru, Brazil
[6] Univ Michigan, Sch Dent, Dept Cariol Restorat Sci & Endodont, Ann Arbor, MI 48109 USA
[7] CES Univ, Dept Orthodont, Medellin, Colombia
[8] Univ Michigan, Sch Dent, Dept Periodont & Oral Med, Ann Arbor, MI 48109 USA
[9] Univ Fed Rio de Janeiro, Sch Dent, Dept Orthodont, Rio De Janeiro, Brazil
关键词
cone-beam computed tomography; dental models; orthodontic tooth movement; reproducibility of results; MESIODISTAL ROOT ANGULATION; PLASTER MODELS; ACCURACY; RELIABILITY; REPRODUCIBILITY; INCLINATION; VARIABILITY; RESORPTION; ANGLES; TOOTH;
D O I
10.1111/ocr.12352
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective To compare the three-dimensional (3D) linear displacements and the mesiodistal and buccolingual angulation changes after orthodontic treatment in digital dental models (DDMs) and 3D models derived from cone-beam computed tomography (CBCT). Settings and Sample Population Digital dental model and CBCT scans were selected from 24 adults who had undergone orthodontic treatment for mandibular anterior crowding. Material and Methods 3D linear displacements and changes in angular measurements (mesiodistal and buccolingual angulation) were assessed in pre- and post-treatment DDM and CBCT images using the software ITK-snap and 3D SlicerCMF. Intra- and inter-rater agreement of measurements in DDM and CBCT were tested using the intraclass correlation coefficient (ICC). DDM and CBCT measurements were compared using the Wilcoxon test (P < .05), ICC and Bland-Altman plots. Results Intra- and inter-rater agreement varied from good (ICC > 0.75) to excellent (ICC > 0.90) for both DDM and CBCT measurements. Although no significant difference between DDM and CBCT methods was observed for linear measurements of tooth movement, the angular assessments were different for most measurements. The agreement between measurements from both assessments varied from poor to excellent. Conclusions Longitudinal assessments of tooth movements including 3D linear displacements and mesiodistal and buccolingual angulation are reproducible when using both DDM and CBCT. Changes in angular measurements due to orthodontic treatment are discordant when measured in the digital models (clinical crown) and in the CBCT images (whole tooth).
引用
收藏
页码:118 / 128
页数:11
相关论文
共 50 条
  • [21] Growth changes in the anterior and middle cranial bases assessed with cone-beam computed tomography in adolescents
    Afrand, Mona
    Oh, Heesoo
    Flores-Mir, Carlos
    Lagravere-Vich, Manuel O.
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2017, 151 (02) : 342 - +
  • [22] The Diagnostic Yield of Dental Radiography and Cone-Beam Computed Tomography for the Identification of Dentoalveolar Lesions in Cats
    Heney, Colleen M.
    Arzi, Boaz
    Kass, Philip H.
    Hatcher, David C.
    Verstraete, Frank J. M.
    FRONTIERS IN VETERINARY SCIENCE, 2019, 6
  • [23] Cone-Beam Computed Tomography for the Evaluation of Dental Pulp Chamber Volume: Implications for Clinics and Teaching
    Llacer-Martinez, Maria
    Martin-Biedma, Benjamin
    Sanz, Maria T.
    Aura-Tormos, Juan I.
    Fos-Galve, Pablo
    Fernandez-Muniz, Zulima
    Vega, Jose A.
    Jovani-Sancho, Mar
    DENTISTRY JOURNAL, 2024, 12 (04)
  • [24] Reliability and validity of miniscrews as references in cone-beam computed tomography and intraoral scanner digital models: study on goat heads
    Jiang, Yiran
    Chen, Gui
    BMC ORAL HEALTH, 2019, 19 (01)
  • [25] Performance of cone-beam computed tomography filters for detection of temporomandibular joint osseous changes
    Verner, Francielle Silvestre
    Portella Guedes Visconti, Maria Augusta
    Junqueira, Rafael Binato
    Dias, Isabela Maddalena
    Ferreira, Luciano Ambrosio
    Devito, Karina Lopes
    ORAL RADIOLOGY, 2015, 31 (02) : 90 - 96
  • [26] Comparison of periodontal evaluation by cone-beam computed tomography, and clinical and intraoral radiographic examinations
    Zhang, Wenjian
    Rajani, Shazia
    Wang, Bing-Yan
    ORAL RADIOLOGY, 2018, 34 (03) : 208 - 218
  • [27] Operational principles for cone-beam computed tomography
    Hatcher, David C.
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2010, 141 (10) : 3S - 6S
  • [28] New evolution of cone-beam computed tomography in dentistry: Combining digital technologies
    Jain, Supreet
    Choudhary, Kartik
    Nagi, Ravleen
    Shukla, Stuti
    Kaur, Navneet
    Grover, Deepak
    IMAGING SCIENCE IN DENTISTRY, 2019, 49 (03) : 179 - 190
  • [29] Reliability of cone-beam computed tomography for temporomandibular joint analysis
    Gorucu-Coskuner, Hande
    Atik, Ezgi
    El, Hakan
    KOREAN JOURNAL OF ORTHODONTICS, 2019, 49 (02) : 81 - 88
  • [30] Comparison of cone-beam computed tomography with multislice computed tomography in detection of small osseous condylar defects
    Jones, Elizabeth M.
    Papio, Melissa
    Tee, Boon Ching
    Beck, Frank M.
    Fields, Henry W.
    Sun, Zongyang
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2016, 150 (01) : 130 - 139