Comparison of linear and angular changes assessed in digital dental models and cone-beam computed tomography

被引:8
作者
Massaro, Camila [1 ,2 ]
Losada, Carolina [3 ]
Cevidanes, Lucia [1 ]
Yatabe, Marilia [1 ]
Garib, Daniela [4 ]
Pereira Lauris, Jose Roberto [5 ]
Ioshida, Marcos [6 ]
Rey, Diego [7 ]
Antonia Alvarez, Maria [7 ]
Benavides, Erika [8 ]
Rios, Hector [8 ]
Fernando Aristizabal, Juan [3 ]
Ruellas, Antonio Carlos [1 ,9 ]
机构
[1] Univ Michigan, Sch Dent, Dept Orthodont & Pediat Dent, 1011 North Univ Ave, Ann Arbor, MI 48109 USA
[2] Univ Sao Paulo, Bauru Dent Sch, Dept Orthodont, Bauru, Brazil
[3] Univ Valle, Dept Orthodont, Cali, Colombia
[4] Univ Sao Paulo, Bauru Dent Sch & Hosp Rehabil Craniofacial Anomal, Dept Orthodont, Bauru, Brazil
[5] Univ Sao Paulo, Bauru Dent Sch, Dept Community Hlth, Bauru, Brazil
[6] Univ Michigan, Sch Dent, Dept Cariol Restorat Sci & Endodont, Ann Arbor, MI 48109 USA
[7] CES Univ, Dept Orthodont, Medellin, Colombia
[8] Univ Michigan, Sch Dent, Dept Periodont & Oral Med, Ann Arbor, MI 48109 USA
[9] Univ Fed Rio de Janeiro, Sch Dent, Dept Orthodont, Rio De Janeiro, Brazil
关键词
cone-beam computed tomography; dental models; orthodontic tooth movement; reproducibility of results; MESIODISTAL ROOT ANGULATION; PLASTER MODELS; ACCURACY; RELIABILITY; REPRODUCIBILITY; INCLINATION; VARIABILITY; RESORPTION; ANGLES; TOOTH;
D O I
10.1111/ocr.12352
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective To compare the three-dimensional (3D) linear displacements and the mesiodistal and buccolingual angulation changes after orthodontic treatment in digital dental models (DDMs) and 3D models derived from cone-beam computed tomography (CBCT). Settings and Sample Population Digital dental model and CBCT scans were selected from 24 adults who had undergone orthodontic treatment for mandibular anterior crowding. Material and Methods 3D linear displacements and changes in angular measurements (mesiodistal and buccolingual angulation) were assessed in pre- and post-treatment DDM and CBCT images using the software ITK-snap and 3D SlicerCMF. Intra- and inter-rater agreement of measurements in DDM and CBCT were tested using the intraclass correlation coefficient (ICC). DDM and CBCT measurements were compared using the Wilcoxon test (P < .05), ICC and Bland-Altman plots. Results Intra- and inter-rater agreement varied from good (ICC > 0.75) to excellent (ICC > 0.90) for both DDM and CBCT measurements. Although no significant difference between DDM and CBCT methods was observed for linear measurements of tooth movement, the angular assessments were different for most measurements. The agreement between measurements from both assessments varied from poor to excellent. Conclusions Longitudinal assessments of tooth movements including 3D linear displacements and mesiodistal and buccolingual angulation are reproducible when using both DDM and CBCT. Changes in angular measurements due to orthodontic treatment are discordant when measured in the digital models (clinical crown) and in the CBCT images (whole tooth).
引用
收藏
页码:118 / 128
页数:11
相关论文
共 40 条
[1]  
Andrews L F, 1976, J Clin Orthod, V10, P174
[2]   6 KEYS TO NORMAL OCCLUSION [J].
ANDREWS, LF .
AMERICAN JOURNAL OF ORTHODONTICS, 1972, 62 (03) :296-&
[3]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[4]   Comparison of mesiodistal root angulation with posttreatment panoramic radiographs and cone-beam computed tomography [J].
Bouwens, Daniel G. ;
Cevidanes, Lucia ;
Ludlow, John B. ;
Phillips, Ceib .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2011, 139 (01) :126-132
[5]   VARIABILITY IN 3 MORPHOLOGIC FEATURES OF THE PERMANENT MAXILLARY CENTRAL INCISOR [J].
BRYANT, RM ;
SADOWSKY, PL ;
HAZELRIG, JB .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1984, 86 (01) :25-32
[6]   CROWN-ROOT ANGLES OF UPPER CENTRAL INCISORS [J].
CARLSSON, R ;
RONNERMAN, A .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1973, 64 (02) :147-154
[7]  
Castro IO, 2018, J OROFAC ORTHOP, V79, P227, DOI 10.1007/s00056-018-0136-2
[8]   Dental models made with an intraoral scanner: A validation study [J].
Cuperus, Anne Margreet R. ;
Harms, Marit C. ;
Rangel, Frits A. ;
Bronkhorst, Ewald M. ;
Schols, Jan G. J. H. ;
Breuning, K. Hero .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2012, 142 (03) :308-313
[9]   Observer reliability of three-dimensional cephalometric landmark identification on cone-beam computerized tomography [J].
de Oliveira, Ana Emilia F. ;
Cevidanes, Lucia Helena S. ;
Phillips, Ceib ;
Motta, Alexandre ;
Burke, Brandon ;
Tyndall, Donald .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 107 (02) :256-265
[10]   3D Mandibular Superimposition: Comparison of Regions of Reference for Voxel-Based Registration [J].
de Oliveira Ruellas, Antonio Carlos ;
Yatabe, Marilia Sayako ;
Souki, Bernardo Quiroga ;
Benavides, Erika ;
Tung Nguyen ;
Luiz, Ronir Raggio ;
Franchi, Lorenzo ;
Soares Cevidanes, Lucia Helena .
PLOS ONE, 2016, 11 (06)