Pulmonary nodule detection with digital projection radiography: an ex-vivo study on increased latitude post-processing

被引:2
作者
Biederer, Juergen
Gottwald, Tobias
Bolte, Hendrik
Riedel, Christian
Freitag, Sandra
Van Metter, Richard
Heller, Martin
机构
[1] Univ Hosp Schleswig Holstein, Dept Diagnost Radiol, Kiel, Germany
[2] Univ Hosp Schleswig Holstein, Inst Med Informat & Stat, Kiel, Germany
[3] Eastman Kodak Co, HI World Wide Res & Dev Rochester Med Phys, Washington, DC USA
关键词
pulmonary nodule; digital radiography; phantom; image latitude;
D O I
10.1007/s00330-006-0367-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate increased image latitude post-processing of digital projection radiograms for the detection of pulmonary nodules. 20 porcine lungs were inflated inside a chest phantom, prepared with 280 solid nodules of 4-8 mm in diameter and examined with direct radiography (3.0x2.5 k detector, 125 kVp, 4 mAs). Nodule position and size were documented by CT controls and dissection. Four intact lungs served as negative controls. Image post-processing included standard tone scales and increased latitude with detail contrast enhancement (log-factors 1.0, 1.5 and 2.0). 1280 sub-images (512x512 pixel) were centred on nodules or controls, behind the diaphragm and over free parenchyma, randomized and presented to six readers. Confidence in the decision was recorded with a scale of 0-100%. Sensitivity and specificity for nodules behind the diaphragm were 0.87/0.97 at standard tone scale and 0.92/0.92 with increased latitude (log factor 2.0). The fraction of "not diagnostic" readings was reduced (from 208/1920 to 52/1920). As an indicator of increased detection confidence, the median of the ratings behind the diaphragm approached 100 and 0, respectively, and the inter-quartile width decreased (controls: p < 0.001, nodules: p=0.239) at higher image latitude. Above the diaphragm, accuracy and detection confidence remained unchanged. Here, the sensitivity for nodules was 0.94 with a specificity from 0.96 to 0.97 (all p > 0.05). Increased latitude post-processing has minimal effects on the overall accuracy, but improves the detection confidence for sub-centimeter nodules in the posterior recesses of the lung.
引用
收藏
页码:1089 / 1100
页数:12
相关论文
共 35 条
[31]  
VANMETTER R, 1992, P SOC PHOTO-OPT INS, V165, P52
[32]   AMBER - A SCANNING MULTIPLE-BEAM EQUALIZATION SYSTEM FOR CHEST RADIOGRAPHY [J].
VLASBLOEM, H ;
KOOL, LJS .
RADIOLOGY, 1988, 169 (01) :29-34
[33]   Dose reduction in skeletal and chest radiography using a large-area flat-panel detector based on amorphous silicon and thallium-doped cesium iodide:: technical background, basic image quality parameters, and review of the literature [J].
Völk, M ;
Hamer, OW ;
Feuerbach, S ;
Strotzer, M .
EUROPEAN RADIOLOGY, 2004, 14 (05) :827-834
[34]   Detection of CT-proved pulmonary nodules: Comparison of selenium-based digital and conventional screen-film chest radiographs [J].
Woodard, PK ;
Slone, RM ;
Sagel, SS ;
Fleishman, MJ ;
Gutierrez, FR ;
Reiker, GG ;
Pilgram, TK ;
Jost, RG .
RADIOLOGY, 1998, 209 (03) :705-709
[35]   COMPUTER-SIMULATED LUNG NODULES IN DIGITAL CHEST RADIOGRAPHS FOR DETECTION STUDIES [J].
YOCKY, DA ;
SEELEY, GW ;
OVITT, TW ;
ROEHRIG, H ;
DALLAS, WJ .
INVESTIGATIVE RADIOLOGY, 1990, 25 (08) :902-907